ASTM F1947-2004 Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits《折叠聚氯乙烯(PVC)管进入现有排水管和管道中的安装标准实施规程》.pdf
《ASTM F1947-2004 Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits《折叠聚氯乙烯(PVC)管进入现有排水管和管道中的安装标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1947-2004 Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits《折叠聚氯乙烯(PVC)管进入现有排水管和管道中的安装标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1947 04An American National StandardStandard Practice forInstallation of Folded Poly (Vinyl Chloride) (PVC) Pipe intoExisting Sewers and Conduits1This standard is issued under the fixed designation F 1947; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes the procedures for the rehabili-tation of s
3、ewer lines and conduits (4 to 15 in. diameter) by theinsertion of a folded PVC pipe, which is heated, pressurized,and expanded against the interior surface of an existing pipewith either a mechanical rounding device or steam pressure.The finished PVC pipe will be continuous and conform to theexistin
4、g conduit. This rehabilitation process can be used in avariety of gravity applications, such as sanitary sewers, stormsewers, and process piping.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information purposes only.1.3
5、This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Docum
6、ents2.1 ASTM Standards:2D 790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating MaterialsD 1600 Terminology for Abbreviated Terms Relating toPlasticsD 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chlor
7、ide)(CPVC) CompoundsD 2122 Test Method of Determining Dimensions of Ther-moplastic Pipe and FittingsF 412 Terminology Relating to Plastic Piping SystemsF 1417 Test Method for Installation Acceptance of PlasticGravity Sewer Lines Using Low-Pressure AirF 1504 Specification for Folded Poly(Vinyl Chlori
8、de)(PVC) Pipe for Existing Sewer and Conduit Rehabilitation2.2 NASSCO Standard:Recommended Specifications for Sewer Collection Sys-tem Rehabilitation33. Terminology3.1 Definitions Terminology used in this practice is inconformance with Terminology F 412 and abbreviations usedin this practice are in
9、accordance with Terminology D 1600,unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 containment tube, nan optional elastomeric materialplaced between the folded pipe and the existing pipe to protectthe folded pipe during insertion, for containment of steamduring th
10、e installation process, and to provide a waterproofbarrier against infiltration, inflow, and standing water. This tuberemains within the pipe but provides no structural support.3.2.2 dimples (dimpling), nWhere a side connectionmeets the existing pipe, there is not existing pipe support forthe PVC pi
11、pe during expansion causing a point of thermoplas-tic pipe expansion slightly beyond the existing pipe wall. Thisformation of an external departure from the formed pipe wallis termed dimpling.3.2.3 folded pipe, nPVC pipe that has been manufacturedin a folded shape for use in existing pipeline rehabi
12、litation (seeFig. 1).3.2.4 formed pipe, nfolded pipe that has been insertedinto an existing sewer or conduit and expanded with heat,pressure, and, if applicable, a rounding device to conform toand take the shape of the existing pipe (see Fig. 1).3.2.5 insertion point, nan existing manhole, existing
13、ac-cess shaft, or an excavated pit that serves as the point ofentrance for the folded pipe into the existing pipe.3.2.6 rounded field sample, na rounded field sample isformed when the folded pipe has been inserted into a mold pipeand expanded with heat and pressure to conform to the moldpipe.3.2.7 r
14、ounding device, na flexible, bullet-shaped device,which may be used to unfold and expand the folded pipe tightlyagainst the wall of the existing pipe.1This practice is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.67 onTren
15、chless Plastic Pipeline Technology.Current edition approved April 1, 2004. Published April 2004. Originallyapproved in 1998. Last previous edition approved in 1998 as F 1947 98.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. F
16、or Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from NASSCO, 140 Circle Drive, Suite 103, Maitland, FL 32751.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United Stat
17、es.3.2.8 termination point, nan existing manhole, existingaccess shaft, or an excavated pit that serves as the point of exitof the folded pipe from the existing pipe.4. Significance and Use4.1 This practice is for use by designers and specifiers,regulatory agencies, owners, and inspection organizati
18、ons whoare involved in the rehabilitation of non-pressure sewers andconduits.5. Materials5.1 The folded poly (vinyl chloride) (PVC) pipe shall be inaccordance with Specification F 1504.5.2 The folded pipe shall be spooled in a continuous lengthfor storage and shipping to the job site. Handling and s
19、toringshall be in accordance with the manufacturers publishedrecommendations.5.3 The optional containment tube should be an elastomericmaterial capable of containing the steam required to processthe folded pipe and serve as a protective waterproofing barrier.The containment tube shall be compatible
20、with the PVCcompound, the folded pipe installation process, and the exist-ing pipe so as not to effect the properties of the finished pipe.6. Installation Recommendations6.1 Cleaning and Inspection:6.1.1 Prior to entering access areas such as manholes, andperforming inspection or cleaning operations
21、, an evaluation ofthe atmosphere to determine the presence of toxic or flammablevapors or lack of oxygen must be undertaken in accordancewith local, state, or federal safety regulations.6.1.2 Cleaning of PipelineInternal debris shall be re-moved from the existing pipeline. The pipeline should beclea
22、ned with hydraulically-powered equipment, high-velocityjet cleaners, or mechanically-powered equipment in accor-dance with NASSCO Recommended Specifications for SewerCollection System Rehabilitation.6.1.3 Inspection of PipelinesInspection of pipelines shallbe performed by experienced personnel train
23、ed in locatingbreaks, obstacles, and service connections by closed circuittelevision. The interior of the pipeline shall be inspectedcarefully to determine the location of any conditions that mayprevent proper installation of the folded pipe, such as protrud-ing service taps, collapsed or crushed pi
24、pe, out-of-roundness,significant line sags, and deflected joints. These conditionsshould be noted and corrected prior to installation.6.1.4 Line ObstructionsThe existing pipeline shall beclear of obstructions that will prevent the proper insertion andfull expansion of the folded pipe such as offset
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF19472004STANDARDPRACTICEFORINSTALLATIONOFFOLDEDPOLYVINYLCHLORIDEPVCPIPEINTOEXISTINGSEWERSANDCONDUITS

链接地址:http://www.mydoc123.com/p-536109.html