ASTM F1741-2008 Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits《现有排水沟和管道修复用机械螺旋.pdf
《ASTM F1741-2008 Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits《现有排水沟和管道修复用机械螺旋.pdf》由会员分享,可在线阅读,更多相关《ASTM F1741-2008 Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits《现有排水沟和管道修复用机械螺旋.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1741 08An American National StandardStandard Practice forInstallation of Machine Spiral Wound Poly (Vinyl Chloride)(PVC) Liner Pipe for Rehabilitation of Existing Sewers andConduits1This standard is issued under the fixed designation F 1741; the number immediately following the design
2、ation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This practice describes the pro
3、cedures for the rehabili-tation of sewer lines and conduits for existing pipelines 6 to180 in. in diameter by the insertion of a machine-madefield-fabricated spiral wound liner pipe into the existingpipeline using a winding machine which remains stationary inthe insertion pit or, alternatively, whic
4、h travels along theinterior of the existing pipeline. These rehabilitation processescan be used in a variety of gravity applications such as sanitarysewers, storm sewers, culverts, and process piping.1.1.1 When using stationary installation equipment for ex-isting pipelines 6 to 48 in., after insert
5、ion, the spiral woundliner pipe is expanded until it presses against the interiorsurface of the existing pipeline. Alternatively, for existingpipelines 6 to 108 in. in diameter, the spiral wound liner pipeis inserted as a fixed diameter into the existing pipeline and isnot expanded, and the annular
6、space between the spiral woundliner pipe and the existing pipe is grouted.1.1.2 When using the traveling installation equipment forexisting pipelines 6 to 180 in. the spiral wound liner pipe isinstalled in contact with the interior surface of the existingpipeline to form a close fit liner, except in
7、 the corners ofrectangular pipes or where obstructions or offsets occur.Alternatively, for existing pipelines 6 to 180 in. in diameter andfor similar sized existing non circular pipelines such as archedor oval or rectangular shapes, the spiral wound liner is installedas a fixed diameter into the exi
8、ting pipeline to form a non-closefit liner and the annular space between the spiral wound linerpipe and the existing pipe is grouted.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for
9、information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of reg
10、ulatory limitations prior to use.1.3.1 Particular attention is drawn to those safety regula-tions and requirements involving entering into and working inconfined spaces.2. Referenced Documents2.1 ASTM Standards:2C 39/C 39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC 109/
11、C 109M Test Method for Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C 495 Test Method for Compressive Strength of Light-weight Insulating ConcreteD 883 Terminology Relating to PlasticsD 1600 Terminology for Abbreviated Terms Relating toPlasticsF 412 Terminology
12、 Relating to Plastic Piping SystemsF 1417 Test Method for Installation Acceptance of PlasticGravity Sewer Lines Using Low-Pressure AirF 1697 Specification for Poly(Vinyl Chloride) (PVC) Pro-file Strip for Machine Spiral-Wound Liner Pipe Rehabili-tation of Existing Sewers and Conduit2.2 Uni-Bell Stan
13、dard:UNI-B-5-89 Recommended Practice for the Installation ofPVC Sewer Pipe33. Terminology3.1 GeneralDefinitions are in accordance with Termi-nologies D 883 and F 412. Abbreviations are in accordancewith Terminology D 1600, unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard
14、:3.2.1 extruded PVC profile stripa product available invarious widths, consisting of a smooth inside surface and aribbed outer surface with mechanically locked male and female1This practice is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of S
15、ubcommittee F17.67 onTrenchless Plastic Pipeline Technology.Current edition approved Nov. 1, 2008. Published December 2008. Originallyapproved in 1996. Last previous edition approved in 2007 as F 174107.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Ser
16、vice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Uni-Bell, 2655 Villa Creek Drive, Suite 155, Dallas TX 75234.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM
17、 International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.edges which are self interlocking, or separate locking stripswhich serve the same purpose Type A and Type B are differentprofiles and are installed by different installation methods. SeeFig. 1 and Tab
18、le 1 for Type A and Fig. 2 and Table 2 for TypeB. See Fig. 1 and Fig. 3 for installation method for Type A andFig. 2 and Fig. 4 for installation method for Type B.3.2.2 insertion pointan existing manhole, existing accessshaft, or excavated pit that serves as the point where a windingmachine field fa
19、bricates the spiral wound liner pipe andsimultaneously inserts the spiral wound liner pipe into theexisting pipeline.3.2.3 non-circular pipearched, oval or rectangular or acombination thereof.3.2.4 production runa continuous extrusion of a givenprofile type.3.2.5 spiral wound liner pipea product fie
20、ld fabricatedfrom extruded PVC profile strip to a round shape, or noncir-cular shape, such as arched or oval or rectangular. (See Fig. 5.)3.2.6 steel reinforcement a shaped steel strip or clipinserted into the inside of the PVC profile to provide additionalreinforcement and stiffening. (See Fig. 3 a
21、nd Fig. 4.)3.2.7 termination pointan existing manhole, existing ac-cess shaft, or an excavated pit that serves as the point of exit ofthe spiral wound liner pipe from the existing pipe.4. Significance and Use4.1 This practice is for use by designers and specifiers,regulatory agencies, owners, and in
22、spection organizations whoare involved in the rehabilitation of non-pressure sewers andconduits. Modifications may be required for specific jobconditions.5. Materials5.1 The extruded profile strip used for the field fabricationof spiral wound liner pipe shall be in accordance withSpecification F 169
23、7.5.2 The profile strip should be coiled onto a reel in acontinuous length for storage and shipping to the job site.Handling and storage should be in accordance with themanufacturers published recommendations.5.3 The adhesive or sealants, or both, used with the maleand female mechanical locking elem
24、ents should be compatiblewith the PVC compound and the spiral wound liner pipeprocess so as not to affect the properties of the spiral woundfinished liner pipe.5.4 The steel reinforcing strips shall be used to reinforce theextruded PVC profile strip, where the design conditions re-quires additional
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF17412008STANDARDPRACTICEFORINSTALLATIONOFMACHINESPIRALWOUNDPOLYVINYLCHLORIDEPVCLINERPIPEFORREHABILITATIONOFEXISTINGSEWERSANDCONDUITS

链接地址:http://www.mydoc123.com/p-535536.html