ASTM F1075-1997(2004) Standard Specification for Dehumidifier Shipboard Mechanically Refrigerated Self-Contained《船上自带机械制冷减湿器的标准规范》.pdf
《ASTM F1075-1997(2004) Standard Specification for Dehumidifier Shipboard Mechanically Refrigerated Self-Contained《船上自带机械制冷减湿器的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1075-1997(2004) Standard Specification for Dehumidifier Shipboard Mechanically Refrigerated Self-Contained《船上自带机械制冷减湿器的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1075 97 (Reapproved 2004)An American National StandardStandard Specification forDehumidifier, Shipboard, Mechanically Refrigerated, Self-Contained1This standard is issued under the fixed designation F 1075; the number immediately following the designation indicates the year oforiginal
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers self-contained dehumidifiersusing hermet
3、ic refrigerant motor-compressors.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 The following safety hazards caveat pertains only to thetest methods portion, Section 11, of this specification: Thisstandard does
4、 not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standar
5、ds:2B 117 Practice for Operating Salt Spray (Fog) ApparatusB 280 Specification for Seamless Copper Tube for AirConditioning and Refrigeration Field ServiceD 1654 Test Method for Evaluation of Painted or CoatedSpecimens Subjected to Corrosive EnvironmentsD 2247 Practice for Testing Water Resistance o
6、f Coatings in100 % Relative Humidity2.2 ASHRAE Standard:3ASHRAE15 Safety Code for Mechanical Refrigeration2.3 Offcial Classification Standard:4Uniform Freight Classification Ratings, Rules, and Regula-tions2.4 UL Standards:5UL 474 DehumidifiersUL 984 Hermetic Refrigerant MotorCompressors2.5 Military
7、 Documents:6MIL-S-901 Specification Requirements for Shock Tests,High Impact (H.I.); Shipboard Machinery, Equipment,and SystemsMIL-STD-167-1 Mechanical Vibrations of ShipboardEquipment, (Type IEnvironmental and Type IIInternally Excited)MIL-D-19947 Specification for Dehumidifier, Space, Me-chanicall
8、y Refrigerated, Self-Contained, Naval Shipboard3. Ordering Information3.1 Orders for products under this specification shall includethe following information, as necessary, to describe adequatelythe desired product:3.1.1 Title, ASTM designation, and year of issue,3.1.2 Quantity (number of dehumidifi
9、ers),3.1.3 Certification if required, and3.1.4 Additions to the specification and supplementary re-quirements, if required.4. Materials and Manufacture4.1 In addition to the requirements cited in this specifica-tion, the dehumidifiers covered by this specification shall bedesigned, constructed, asse
10、mbled, and tested to comply withUL 474, UL 984, and ASHRAE Standard 15. In the event ofdifferences between any of the requirements of this specifica-tion and those of other referenced documents, the requirementsof this specification shall govern. The manufacturer shallcertify compliance with the abo
11、ve standards for equipmentfurnished and shall be cited in the UL Electrical Appliance andUtilization Equipment product directories.4.2 The dehumidifier shall consist of a motor-compressor,condensing unit, dehumidifying coil, air-circulating fan, andaccessories, all enclosed within a metal cabinet. T
12、he dehumidi-fier shall be complete, self-contained with the refrigeration1This specification is under the jurisdiction of ASTM Committee F25 on Shipsand Marine Technology and is the direct responsibility of Subcommittee F25.11 onMachinery and Piping Systems.Current edition approved May 1, 2004. Publ
13、ished May 2004. Originallyapproved in 1987. Last previous edition approved in 1997 as F 1075 97.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docume
14、nt Summary page onthe ASTM website.3Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329.4Available from Uniform Classification Agent, Tariff Publication Officer, Room1106, 222 South Riverside Plaza, Chicag
15、o, IL 60606.5Available from Underwriters Laboratories Inc., 333 Pfingsten Rd., North-brook, IL 60062.6Available from Superintendent of Documents, U.S. Government PrintingOffice, Washington, DC 20402.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
16、United States.equipment dehydrated, and charged with the necessary operat-ing quantity of refrigerant and oil. Each unit shall be ready foroperation after removal of shipping protection, opening ofvalves where provided, and connection to electric power.4.3 The motor-compressor shall be of the hermet
17、ic type andshall consist of a compressor and motor enclosed in a gastightshell. The hermetic compressor unit shall conform to UL 984and shall be at least16 hp. Equipment shall operate on 115-V,single-phase, 60-cycle alternating current. The unit shall beprotected against overload by a thermal protec
18、tor built into themotor. The thermal protection shall be either the manual orautomatic reset type.4.4 Piping necessary for the satisfactory operation of theequipment shall be provided by the manufacturer. Tubing shallbe made of copper in accordance with Specification B 280.Piping connections shall b
19、e arranged in such a manner so as notto impair the vibration-isolation properties of absorption-typemounts, where such mounts are provided. Piping shall besecurely supported to minimize strain and vibration. Pipingconnections shall not be made of soft solder.4.5 Materials used in the manufacture of
20、the equipmentshall be corrosion-resistant or treated to resist corrosion. Themethod of manufacture shall not impair physical, structural, orcorrosion-resistant properties of the components. Materials,coatings, and paint systems shall satisfactorily pass the appli-cable salt spray and humidity test s
21、pecified in this specification.4.6 Bolts, nuts, studs, pins, screws, and such other fasten-ings or fittings shall be of a corrosion-resisting material, or ofa material treated in a manner to render it adequately resistantto corrosion. Screws exposed in final assembly shall becorrosion-resisting mate
22、rial.4.7 Similar parts, including repair parts, or correspondingapparatus furnished on the same contract or order, or built tothe same drawings, shall be strictly interchangeable without thenecessity of further machining or hand fitting of any kind.4.8 A plastic or other chemically inert container s
23、hall beprovided for collecting the condensate. The container shall beof a size and configuration that will fit within the cabinetenclosure. The container shall be provided with baffles toprevent the overflow or spilling of water and shall be readilyremovable from the dehumidifier cabinet. A male fit
24、ting shallbe provided from the container for connection of a 0.375-in.(10-mm) inside diameter flexible rubber tubing for draining thecondensate (wall thickness 0.125 in. (3 mm). The rubbertubing will not be required to be furnished by the contractor.4.9 Provision shall be made in the frame to permit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF107519972004STANDARDSPECIFICATIONFORDEHUMIDIFIERSHIPBOARDMECHANICALLYREFRIGERATEDSELFCONTAINED 船上

链接地址:http://www.mydoc123.com/p-534111.html