ASTM E1851-2015 Standard Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures《耐久刚性壁浮动结构电磁屏蔽功效的标准试验方法》.pdf
《ASTM E1851-2015 Standard Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures《耐久刚性壁浮动结构电磁屏蔽功效的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1851-2015 Standard Test Method for Electromagnetic Shielding Effectiveness of Durable Rigid Wall Relocatable Structures《耐久刚性壁浮动结构电磁屏蔽功效的标准试验方法》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1851 09E1851 15Standard Test Method forElectromagnetic Shielding Effectiveness of Durable RigidWall Relocatable Structures1This standard is issued under the fixed designation E1851; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This te
3、st method covers the determination of the electromagnetic shielding effectiveness of durable relocatable shieldedenclosures.1.1.1 The intended application of this test method is for virgin shielded enclosures that do not have any equipment or equipmentracks. It is recommended that tests be conducted
4、 before the interior finish work begins. However, the shield assembly includingall enclosure penetrations shall be completed and required penetration protection devices shall be installed in accordance with thedesign specification. The test method can also be used on existing shielded enclosures aft
5、er repair work is done to verifyworkmanship, but it may be necessary to remove equipment or equipment racks to gain access to a test area.1.1.2 The test procedures delineated in this document are comprehensive and may require several days to complete for aroom-size shielded enclosure. A user can app
6、ly this test method for a first article test that requires proof of concept and validationof design and fabrication technique. Appendix X2 provides guidance on choosing test points so shielding effectiveness tests on aroom-size shielded enclosure may be completed in about one-half day for which it a
7、pplies to shielded enclosures coming off anassembly line.1.2 This test method is for use in the following frequency ranges: 140 to 160 kHz, 14 to 16 MHz, 300 to 500 MHz, 900 to 1000MHz, and 8.5 to 10.5 GHz. Specific test frequencies within these ranges are required (see 10.1.111.1.1 and 11.2.110.2.1
8、).).Additional measurements in the range of 10 kHz to 10.1.5.110.5 GHz may be performed. For specific applications, the frequencyrange may be extended from 50 Hz to 40 GHz. Appendix X1 provides guidance on selecting measurement frequencies.1.3 This test method is not applicable to individual compone
9、nts such as separate walls, floors, ceilings, or shielded racks.1.4 This standard may involve hazardous materials, operations, equipment, or any combination.1.5 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.1.6 This standard does
10、 not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standar
11、ds:2E631 Terminology of Building ConstructionsE1749 Terminology Relating to Rigid Wall Relocatable Shelters2.2 IEEE Standards:3IEEE Std 299-1997 IEEE Standard Method for Measuring the Effectiveness of Electromagnetic Shielding EnclosuresIEEE Std C95.1-1991 IEEE Standard for Safety Levels with Respec
12、t to Human Exposure to Radio Frequency ElectromagneticFields, 3 kHz to 300 GHz1 This test method is under the jurisdiction of ASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.53 on Materialsand Processes for Durable Rigidwall Relocatable Structures.
13、Current edition approved Nov. 1, 2009Sept. 1, 2015. Published December 2009September 2015. Originally approved in 1997. Last previous edition approved in 20042009as E1851 04.E1851-09. DOI: 10.1520/E1851-09.10.1520/E1851-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or conta
14、ctASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from Institute of Electrical and Electronics Engineers, Inc. (IEEE), 445 Hoes Ln., P.O. Box 1331, Piscataway, NJ 08854-1331,08
15、854-4141, http:/www.ieee.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends
16、 that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.3 Military Standa
17、rd:4MIL-STD-188-125 High Altitude Electromagnetic Pulse (HEMP) Protection for Ground Based C4I Facilities PerformingCritical, Time-Urgent Missions2.4 OSHA Standard:5OSHA Regulation, 29 CFR 1910, Department of Labor, July 19924 Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Sec
18、tion D, DLA Document Services, Building 4/D, 700 Robbins Ave., Philadelphia, PA19111-5098, http:/dodssp.daps.dla.mil.19111-5094, http:/quicksearch.dla.mil.5 Available from Occupational Safety and Health Administration (OSHA), 200 Constitution Ave., NW, Washington, DC 20210, http:/www.osha.gov.E1851
19、1523. Terminology3.1 DefinitionsSee Terminologies E631 and E1749 for definitions of general terms used in this test method.4. Summary of Test Method4.1 Test ConfigurationA transmitting antenna is connected to an electromagnetic source set to a specific frequency andamplitude.Areceiving antenna is pl
20、aced a specified distance from the transmitting antenna, and the received electromagnetic fieldlevel is recorded as a reference or calibration measurement.The transmitting antenna and electromagnetic source are placed outsidethe shielded enclosure. The receiving antenna and associated test equipment
21、 are placed inside the shielded enclosure. Thetransmitting and receiving antennas separation, frequency, and amplitude are the reference measurements. The transmitting andreceiving antennas are at the same height for a given test point. The received electromagnetic field level is recorded as the tes
22、tmeasurement. The ratio of the test measurement to the reference measurement is the electromagnetic shielding effectiveness of theshielded structure at the measurement location and frequency. The logarithm of this ratio is typically used in expressing theshielding effectiveness in decibels.4.2 Test
23、FrequenciesA summary of nominal test frequencies and corresponding test configurations is shown in Table 1.5. Significance and Use5.1 This standard provides measurement procedures for determining the electromagnetic shielding effectiveness of durable rigidwall relocatable shielded enclosures. This s
24、tandard specifies a method for comparing the shielded enclosure performance ofstructures provided by different suppliers. In addition, this standard is written to minimize variations in measured shieldingeffectiveness at a given frequency and test point regardless of test personnel, equipment, and t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME18512015STANDARDTESTMETHODFORELECTROMAGNETICSHIELDINGEFFECTIVENESSOFDURABLERIGIDWALLRELOCATABLESTRUCTURES

链接地址:http://www.mydoc123.com/p-529641.html