1、Designation: E1755 01 (Reapproved 2015)Standard Test Method forAsh in Biomass1This standard is issued under the fixed designation E1755; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenth
2、eses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of ash,expressed as the mass percent of residue remaining after dryoxidation (oxidation at 575 6 25C), of hard
3、 and soft woods,herbaceous materials (such as switchgrass and sericea), agri-cultural residues (such as corn stover, wheat straw, andbagasse), wastepaper (such as office waste, boxboard, andnewsprint), acid and alkaline pretreated biomass, and the solidfraction of fermentation residues. All results
4、are reportedrelative to the 105C oven-dried mass of the sample. Forparticulate wood fuels, Test Method E1534 should be used.1.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
5、 is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E1534 Test Method for Determination of Ash Content ofParticulate Wood FuelsE1756
6、 Test Method for Determination of Total Solids inBiomassE1757 Practice for Preparation of Biomass for Composi-tional Analysis3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 ashthe inorganic residue left after ignition at 575 625C.4. Significance and Use4.1 The ash content is a
7、n approximate measure of themineral content and other inorganic matter in biomass.4.2 The ash content is used in conjunction with other assaysto determine the total composition of biomass samples.5. Apparatus5.1 Ashing Crucibles, 50 mL, platinum crucibles arepreferred, but silica or porcelain crucib
8、les may be used.5.2 Muffle Furnace, an electric furnace is recommended forigniting the sample. The furnace should be fitted with anindicating pyrometer or thermocouple, so that the requiredtemperature of 575 6 25C can be maintained.5.3 Analytical Balance, sensitive to 0.1 mg.5.4 Desiccator, using an
9、hydrous calcium sulfate.5.5 Drying Oven, with temperature control of 105 6 2C.6. Test Specimen6.1 Test specimens suitable for analysis by this test methodare as follows:6.1.1 Prepared biomass samples that have been preparedaccording to Practice E1757.6.1.2 Biomass feedstocks, dried at 105C according
10、 to TestMethod E1756,6.1.3 Pretreated biomass, dried at 105C according to TestMethod E1756, and6.1.4 The solids fraction of fermentation residues, dried at105C according to Test Method E1756.6.2 The test specimen shall consist of approximately 0.5 to1.0 g of sample obtained in such a manner to ensur
11、e that it isrepresentative of the entire lot of material being tested.NOTE 1All samples should be ground or milled to reduce the size ofthe large pieces to less than 1 mm in diameter. The sample is then redriedat 105C prior to testing. Prepared biomass can be used in place of 105Cdried material, but
12、 the mass of the material must be corrected for itsmoisture content by using Test Method E1756, prior to calculating the ash.7. Procedure7.1 Mark a pan or crucible with a unique identification usinga porcelain marker, place it in the muffle furnace at 575 625C. Remove the pan or crucible from the fu
13、rnace, cool toroom temperature in a desiccator, and weigh to the nearest 0.11This test method is under the jurisdiction of ASTM Committee E48 onBioenergy and Industrial Chemicals from Biomass and is the direct responsibility ofSubcommittee E48.05 on Biomass Conversion.Current edition approved June 1
14、, 2015. Published July 2015. Originally approvedin 1995. Last previous edition approved in 2007 as E1755-01(2007)07. DOI:10.1520/E1755-01R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volu
15、me information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1mg. For an aluminum pan, two hours of heating at 575 6 25Cwill be sufficient to bring the pan to constant
16、mass. With acrucible, however, the following procedure is used: place thecrucible in the furnace at 575 6 25C for 3 h. Remove thecrucible and place in a desiccator. Allow the crucible to cool toroom temperature and then weigh the crucible to the nearest0.1 mg. Record this mass. After weighing, retur
17、n the crucibleto the furnace for1hat5756 25C, cool again in thedesiccator, and reweigh. Repeat this step until the mass of thecrucible varies by less than 0.3 mg from the previous weighing.Record this final mass as the crucible tare mass, mcont. Keep thepan or crucible in a desiccator until used.7.2
18、 Weigh approximately 0.5 to 1.0 g, to the nearest 0.1 mg,of a test specimen into the tared pan or crucible. If the samplebeing analyzed is a test specimen dried at 105C, the sampleshould be stored in a desiccator until use. For a 105C driedtest sample, record the mass (container plus sample mass) as
19、the initial mass, mod. For prepared biomass samples preppedaccording to Practice E1757, record the mass (container plussample mass) as the initial mass, mar.NOTE 2For prepared biomass samples, it is recommend that samplesfor moisture determination should be weighed out at the same time as thesamples
20、 for the ash determination. If this is done at a later time it canintroduce an error in the calculation because ground biomass can rapidlygain or lose moisture when exposed to the atmosphere.7.3 Place the container and contents in the muffle furnaceand ignite at 575 6 25C for a minimum of 3 h, or un
21、til all thecarbon is eliminated. To avoid flaming, initially heat thesample to 250C at a rate of 10 K/min and hold for 30 minbefore increasing the temperature to 575 6 25C. Avoidheating above the maximum stated temperature.NOTE 3For test specimens containing high amounts of ash (greaterthan 5 % by m
22、ass), it will be necessary to increase the time in the furnaceto overnight to ensure complete elimination of the carbon. This ignitiontime period should not exceed 24 h.7.4 Taking care to protect the test container from strongdrafts to avoid mechanical loss of test specimen, remove thepan or crucibl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME175520012015STANDARDTESTMETHODFORASHINBIOMASS 生物 灰分 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-529395.html