1、Designation: E 1111 07Standard Test Method forMeasuring the Interzone Attenuation of Open OfficeComponents1This standard is issued under the fixed designation E 1111; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method describes the measurement and evaluation of acoustical performance ofcomponents affecting speech privacy
3、 in open-plan spaces. The maximum privacy theoreticallyavailable at normal working distances in open-plan spaces, with partial height space dividers (screens),is insufficient without the assistance of relatively elevated background masking sound levels. Thus, theprovision of adequate speech privacy
4、in open-plan offices and schools is one of the most difficult tasksin the architectural acoustics field. This test method provides a means of objectively measuring therelevant acoustical characteristics of three major components of open-plan spaces, the ceiling system,furniture panels used as acoust
5、ical barriers, and wall finishes which attenuate reflected sound.Furniture panels may be tested for their capacity as an acoustical barrier and/or the degree to whichthey may reduce reflected sound.1. Scope1.1 This test method covers the measurement of the inter-zone attenuation for three components
6、 of open-plan spaces:1.1.1 Ceiling systems when used in conjunction withpartial-height space dividers. This arrangement is commonlyused in offices to achieve speech privacy between work zonesin the absence of full-height partitions. This test method isapplicable to any ceiling configuration, includi
7、ng, for example,a pattern of sound-reflective panels in an otherwise sound-absorptive ceiling. This test method generally requires use of afixed space divider height of 1.50 m (60 in). In recognition oftrends toward alternate divider heights in open office environ-ments, measurements with an alterna
8、te divider height may beconducted in accordance with this standard.1.1.2 Furniture panels used as acoustical barriers in open-plan spaces to provide speech privacy or sound isolationbetween working positions.1.1.3 Vertical panels, including wall finishes such as sound-absorbent panels, and furniture
9、 panels or screens which mayreflect sound. It may not be applicable to such items as windowfinishes or furniture other than panels if these differ signifi-cantly from flat wall panels.1.1.4 The combination of results from the various compo-nents of an open-plan office is beyond the scope of thisstan
10、dard.1.2 Unless otherwise qualified, all dimensions specified inthis test method shall be understood to have a tolerance of 66mm (614 in.) The values stated in SI units are to be regardedas the standard. The values given in parentheses are providedfor information only.1.3 This standard does not purp
11、ort to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 4
12、23 Test Method for Sound Absorption and Sound Ab-sorption Coefficients by the Reverberation Room MethodC 634 Terminology Relating to Environmental AcousticsE 795 Practices for Mounting Test Specimens DuringSound Absorption TestsE 1110 Classification for Determination of ArticulationClass1This test m
13、ethod is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.02 on Open Plan Spaces.Current edition approved April 1, 2007. Published April 2007. Originallyapproved in 1986. Last previous edition approved in 2005 as E
14、 1111 05.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive
15、, PO Box C700, West Conshohocken, PA 19428-2959, United States.E 1179 Specification for Sound Sources Used for TestingOpen Office Components and SystemsE 1374 Guide for Open Office Acoustics and ApplicableASTM Standards2.2 ANSI Standards:S1.4 Specification for Sound Level Meters3S1.6 Preferred Frequ
16、encies and Band Numbers for Acous-tical Measurements3S1.11 Specification for Octave Band and Fractional-Octave-Band Analog and Digital Filters33. Terminology3.1 The following terms used in this test method havespecific meanings that are defined in Terminology C 634:3.1.1 acoustical barrier, ambient
17、noise, diffraction, level,(sound) absorption coefficient, sound pressure levels, pinknoise, white noise.3.2 Definitions of Terms Defined in Other Standards notincluded in Terminology C 634:3.2.1 The term source point is defined in SpecificationE 1179.3.3 Definitions of Terms Specific to This Standar
18、d:3.3.1 furniture panela furnishing that does not extend tothe ceiling, and that is used to subdivide an open-plan spaceand provide a degree of visual and acoustical privacy. Furniturepanels include interlocking systems furniture and freestandingscreens.3.3.2 nominal reference levelfor a one-third o
19、ctave-band,the arithmetic mean of sound pressure levels measured atspecified positions relative to the source in a region free fromreflections.3.3.3 interzone attenuationat a specified position, for aone-third octave band, the difference between the nominalreference level and the sound pressure leve
20、l at the specifiedpoint.3.3.4 nominal interzone attenuationfor a one-thirdoctave-band, at a specified point, the arithmetic mean interzoneattenuation calculated using the interzone attenuation for thepoint in question and for two adjacent positions 0.30 m (1 ft)along the survey path.4. Summary of Te
21、st Method4.1 The test facility is essentially an expanse of floor andceiling in which all surfaces excluding the floor and testspecimen have negligible sound reflections. The facility maybe set up in a laboratory, in a mock-up of a proposed building,or in a completed building. The configuration of t
22、he room willdepend on the open-plan component being tested.4.1.1 For testing a ceiling system, a standard space divideris positioned with such dimensions and construction that soundgenerated on one side can reach a measuring point on the otherside only by way of diffraction over the top of the space
23、 dividerand by reflection from the ceiling. With the diffracted compo-nent fixed by the dimensions of the space divider and by theheight of the source and measurement position, the differencebetween the sound pressure levels measured on each side of thespace divider provides a comparative measure of
24、 the contribu-tion of ceiling system reflection to the total sound transmission.See Fig. 1.4.1.2 For a furniture panel tested as an acoustical barrier, thepanel is arranged such that it blocks the direct path of soundfrom the sound source to the measuring microphones. Soundgenerated by the sound sou
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME11112007STANDARDTESTMETHODFORMEASURINGTHEINTERZONEATTENUATIONOFOPENOFFICECOMPONENTS 测量 办公 部件 区间

链接地址:http://www.mydoc123.com/p-527931.html