ASTM E389-2003(2008)e1 781 Standard Test Method for Particle Size or Screen Analysis at No 4 (4 75-mm) Sieve and Coarser for Metal-Bearing Ores and Related Materials《用4号筛(4 75 mm)及.pdf
《ASTM E389-2003(2008)e1 781 Standard Test Method for Particle Size or Screen Analysis at No 4 (4 75-mm) Sieve and Coarser for Metal-Bearing Ores and Related Materials《用4号筛(4 75 mm)及.pdf》由会员分享,可在线阅读,更多相关《ASTM E389-2003(2008)e1 781 Standard Test Method for Particle Size or Screen Analysis at No 4 (4 75-mm) Sieve and Coarser for Metal-Bearing Ores and Related Materials《用4号筛(4 75 mm)及.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 389 03 (Reapproved 2008)1Standard Test Method forParticle Size or Screen Analysis at No. 4 (4.75-mm) Sieveand Coarser for Metal-Bearing Ores and Related Materials1This standard is issued under the fixed designation E 389; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial corrections were made throughout in September 200
3、8.1. Scope1.1 This test method covers the determination of the sizedistribution by screen analysis of metal-bearing ores andrelated materials at No. 4 (4.75-mm) sieve and coarser.1.2 The values stated in inch-pound units are to be regardedas standard. The SI values given in parentheses are providedf
4、or information only and are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility the user of this standard to establish appropriatesafety and health practices and determine the applicability ofregula
5、tory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E11 Specification for Wire Cloth and Sieves for TestingPurposesE 135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE 276 Test Method for Particle Size or Screen Analysis atNo. 4 (4.75-mm) Si
6、eve and Finer for Metal-Bearing Oresand Related MaterialsE 882 Guide for Accountability and Quality Control in theChemical Analysis Laboratory3. Terminology3.1 Definitions:3.1.1 For definitions of terms in this test method, refer toTerminology E 135.4. Summary of Test Method4.1 The sample is passed
7、through a bank of standard sievesby agitation. The screening technique described in this proce-dure may be used on any solid particles that can be dried so thatsieve blinding does not occur.5. Significance and Use5.1 This test method is intended to be used for compliancewith compositional specificat
8、ions for particle size distribution.It is assumed that all who use this procedure will be trainedanalysts capable of performing common laboratory practicesskillfully and safely. It is expected that work will be performedin a properly equipped laboratory and that proper wastedisposal procedures will
9、be followed. Follow appropriatequality control practices such as those described in GuideE 882.6. Apparatus and Materials6.1 U.S. Standard Sieves, conforming to the requirements ofSpecification E11.6.2 Sieve Shaker, mechanical or manual.6.3 Drying Oven, of approximate size and capable ofmaintaining
10、a uniform temperature at 110 C 6 5 C.6.4 Sample Splitter or Riffle, with openings not less thanthree times the size of the largest particle.6.5 Scales and Weights, of adequate accuracy.6.6 Pans, for holding samples.6.7 Brushes, for cleaning sieves and pans.7. Sample Preparation7.1 If necessary, redu
11、ce the sample by means of a samplesplitter or riffle, or by coning and quartering, or by thealternate-shovel method. Dry at 110 C 6 5 C to constantweight.1This test method is under the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Related Materials and is the direct
12、responsibility of Subcommittee E01.02 on Ores, Concentrates, and Related Metal-lurgical Materials.Current edition approved Sept. 1, 2008. Published September 2008. Originallyapproved in 1969. Last previous edition approved in 2003 as E 389 03.2For referenced ASTM standards, visit the ASTM website, w
13、ww.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NOT
14、E 1The size of the sample is very important in sieve analysisbecause the number of particles on a sieve surface affects the probabilityof any one particle passing through the sieve at a given time. The moreparticles there are on a sieve, the greater probability that any one particleis hindered from
15、getting into a position to pass through the opening.Avoidoverloading the sieves.7.2 Screen the test sample from 7.1 on a No. 4 (4.75-mm)sieve. Weigh the material passing the sieve and, if desired,screen in accordance with Test Method E 276.8. Procedure8.1 Clean the sieves and apparatus by brushing.8
16、.2 Nest the selected sieves and fit a pan to the bottom sieve.Place the material which was retained on the No. 4 (4.75-mm)sieve from 7.2 in the top sieve. Cover and clamp in themechanical shaker and shake for the length of time as specifiedin 8.3.8.3 Length of Screening Time or End PointThe screenin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME38920032008E1781STANDARDTESTMETHODFORPARTICLESIZEORSCREENANALYSISATNO4475MMSIEVEANDCOARSERFORMETALBEARINGORESANDRELATEDMATERIALS

链接地址:http://www.mydoc123.com/p-527529.html