ASTM D7454-2014e1 4043 Standard Test Method for Determination of Vibrated Bulk Density of Calcined Petroleum Coke using a Semi-Automated Apparatus《使用半自动化仪器测定煅烧石油焦炭振动体密度的标准试验方法》.pdf
《ASTM D7454-2014e1 4043 Standard Test Method for Determination of Vibrated Bulk Density of Calcined Petroleum Coke using a Semi-Automated Apparatus《使用半自动化仪器测定煅烧石油焦炭振动体密度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7454-2014e1 4043 Standard Test Method for Determination of Vibrated Bulk Density of Calcined Petroleum Coke using a Semi-Automated Apparatus《使用半自动化仪器测定煅烧石油焦炭振动体密度的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7454 141Standard Test Method forDetermination of Vibrated Bulk Density of CalcinedPetroleum Coke using a Semi-Automated Apparatus1This standard is issued under the fixed designation D7454; the number immediately following the designation indicates the year oforiginal adoption or, in th
2、e case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEResearch Report information was added editorially to the Precision and Bias section in Septem
3、ber 2014.1. Scope*1.1 This test method covers the determination of bulkdensity of a representative 2-kg sample of calcined petroleumcoke, after vibration to increase compaction, using a semi-automatic apparatus.1.2 The procedure is applied, but not limited, to particlespassing through a 4.75-mm open
4、ing sieve and retained on a1.18-mm opening sieve. Further, the procedure is applied, butnot limited, to a specific test sample having particles passingthrough a 0.85-mm opening sieve and retained on a 0.425-mmopening sieve. This procedure could also be applied to othersieve fractions being agreed on
5、 in the aluminum industry asspecified in Annex A1.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibil
6、ity of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E11 Specification for Woven Wire Test Sieve Cloth and TestSievesE691 Practice for Conducting an In
7、terlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 Definitions:3.1.1 as-calcined particles, nof coke, those particles thathave not been subject to laboratory crushing.3.1.2 bulk density, nof coke, the ratio of the mass of acollection of particles of a specified particle
8、size range to thevolume occupied.3.1.3 laboratory crushed particles, n of coke, those par-ticles of petroleum coke that have been crushed in thelaboratory.4. Summary of Test Method4.1 The natural 4.75 by 1.18-mm fraction of the originalcoke is separated from the sample by manual screening, groundto
9、0.85 by 0.425 mm, and fed at a controlled rate into agraduated cylinder on a vibrating table until the coke reachesthe 50-mL mark. The collected coke is weighed and the bulkdensity is calculated and reported in g/mL.4.2 The procedure is empirical; close adherence to thetechnique and apparatus is nec
10、essary to ensure reproducibleresults. To provide comparable results in different locations,exact adjustments of operating parameters are required usingreference samples.5. Significance and Use5.1 Vibrated bulk density (VBD) is an indicator of calcinedpetroleum coke porosity, which affects its suitab
11、ility for use inpitch-bonded carbon applications. (WarningVibrated bulkdensity for a sample of calcined petroleum coke is stronglydependent upon average particle size and particle size range.Bulk density tends to increase with decreasing coke size. Anarrow particle size range for this test minimizes
12、 the possibilityfor variation due to skewing of the test sample toward eitherscreen defining the sample.)6. Apparatus6.1 Pan BalanceAccurate to 0.1 g, with a capacity of2.0 kg.6.2 Riffle SamplerEnclosed drawer, approximately 380 by290 by 360 mm, 24-slot.6.3 SievesMeeting Specification E11.1This test
13、 method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.05 on Properties of Fuels, Petroleum Coke and Carbon Material.Current edition approved May 1, 2014. Published May 2014. Originallyapproved in
14、 2008. Last previous edition approved in 2008 as D7454 08. DOI:10.1520/D7454-14E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary pa
15、ge onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.4 Sieve ShakerElectrical drive with an automatic timer;should have a rotating and tapping action.
16、6.5 Roller CrusherLaboratory type; glass hardened rolls;roll diameter of approximately 150 mm; roll width of approxi-mately 150 mm; gap range from 0 to 12.7 mm.6.6 Thickness Gauges (leaf-type)0.4, 1.0, 1.5, and4.0 mm.6.7 Semi-Automated VBD Apparatus, As shown in Fig. 1.See also comments about instal
17、lation in Annex A1.6.7.1 Borosilicate Glass Powder Funnels8-cm diameterfunnels with 1-cm internal diameter and stems about 3.5 cmlong. Tips of funnels should be cut at a right (not oblique)angles (see Fig. 1). The distance between the tip of the upperfunnel and the bottom of the vibrating bowl shoul
18、d be around6 mm.6.7.2 Electromagnetic JoggerWith approximately 175- by250-mm deck, and shall be capable of vibrating at a frequencyof 60 Hz.6.7.3 Acrylic ClampTo hold cylinder.6.7.4 Vibrating BowlHaving a diameter of approximately7.5 cm and a height of 4.0 mm, such as that being used withrotary micr
19、o riffler.6.7.5 Displacement Probe and Reading DevicePermittingcontinuous monitoring of amplitude vibration.6.7.6 Graduated Cylinder50 mL, with inside diameterapproximately 23 mm and height approximately 19 cm.6.7.7 Photoelectric Sensor Switch.6.7.8 Control DevicePermitting real-time adjustment ofth
20、e vibration amplitude and automatic stopping of the feedingdevice when the coke level reaches the 50-mL mark.6.7.9 Automatic Timer, Clock, or WatchWith a secondindicator.6.7.10 Line Stabilizer (Optional)Use if the noise on thepower line is significant and affects the apparatus performance.6.7.11 Rou
21、nd Level.6.7.12 Balance0 to 300 g and sensitive to 0.01 g.7. Hazards7.1 Exercise care in the operation of the roll crusher.7.1.1 Wear safety glasses and keep hands clear when feed-ing material.7.1.2 Turn power off at the source when equipment isopened for cleaning after the grinding operation.8. Sam
22、ple Preparation8.1 Reduce the original sample volume to about 1 kg.8.2 Manually screen out the natural to 4.75 by 1.18 mm and0.85-mm fraction.8.8 Adjust the roller spacing to 0.5 mm and grind the 0.85-mm fraction. Manually screen out the 0.85 byFIG. 1 Example of Semi-Automated Apparatus Set-UpD7454
23、14120.425-mm fraction and add this fraction into the same plasticbag referred to in 8.7. Discard the 0.85-mm fraction, if present.8.9 Repeat, if necessary, the grinding procedure in 8.8 of the 0.85-mm fraction, until all particles pass through the0.85-mm sieve. It is possible that at this step, abou
24、t 1 to3gofparticles larger than 0.85 mm cannot be ground to finerparticles. Do not attempt to grind them using roller spacingsmaller than 0.5 mm. Simply discard them (these particles arein general, plate-like shape particles and should not be used forbulk density measurement).8.10 Manually mix the c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD74542014E14043STANDARDTESTMETHODFORDETERMINATIONOFVIBRATEDBULKDENSITYOFCALCINEDPETROLEUMCOKEUSINGASEMIAUTOMATEDAPPARATUS

链接地址:http://www.mydoc123.com/p-525533.html