ASTM D7454-2014 red 1330 Standard Test Method for Determination of Vibrated Bulk Density of Calcined Petroleum Coke using a Semi-Automated Apparatus《采用半自动化仪器测定煅烧石油焦炭振动体密度的标准试验方法》.pdf
《ASTM D7454-2014 red 1330 Standard Test Method for Determination of Vibrated Bulk Density of Calcined Petroleum Coke using a Semi-Automated Apparatus《采用半自动化仪器测定煅烧石油焦炭振动体密度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7454-2014 red 1330 Standard Test Method for Determination of Vibrated Bulk Density of Calcined Petroleum Coke using a Semi-Automated Apparatus《采用半自动化仪器测定煅烧石油焦炭振动体密度的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7454 08D7454 14Standard Test Method forDetermination of Vibrated Bulk Density of CalcinedPetroleum Coke using a Semi-Automated Apparatus1This standard is issued under the fixed designation D7454; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers the determination of bulk density of a represent
3、ative 2-kg sample of calcined petroleum coke, aftervibration to increase compaction, using a semi-automatic apparatus.1.2 The procedure is applied, but not limited, to particles passing through a 4.75-mm opening sieve and retained on a 1.18-mmopening sieve. Further, the procedure is applied, but not
4、 limited, to a specific test sample having particles passing through a0.85-mm opening sieve and retained on a 0.425-mm opening sieve. This procedure could also be applied to other sieve fractionsbeing agreed on in the aluminum industry as specified in Annex A1.1.3 The values stated in SI units are t
5、o be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices
6、and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E11 Specification for Woven Wire Test Sieve Cloth and Test SievesE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Terminology3.1 Definit
7、ions:3.1.1 as-calcined particles, nof coke, those particles that have not been subject to laboratory crushing.3.1.2 bulk density, nof coke, the ratio of the mass of a collection of particles of a specified particle size range to the volumeoccupied.3.1.3 laboratory crushed particles, n of coke, those
8、 particles of petroleum coke that have been crushed in the laboratory.4. Summary of Test Method4.1 The natural 4.75 by 1.18-mm fraction of the original coke is separated from the sample by manual screening, ground to 0.85by 0.425 mm, and fed at a controlled rate into a graduated cylinder on a vibrat
9、ing table until the coke reaches the 50-mL mark.The collected coke is weighed and the bulk density is calculated and reported in g/mL.4.2 The procedure is empirical; close adherence to the technique and apparatus is necessary to ensure reproducible results. Toprovide comparable results in different
10、locations, exact adjustments of operating parameters are required using reference samples.5. Significance and Use5.1 Vibrated bulk density (VBD) is an indicator of calcined petroleum coke porosity, which affects its suitability for use inpitch-bonded carbon applications. (WarningVibrated bulk densit
11、y for a sample of calcined petroleum coke is strongly dependent1 This test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.05 on Properties of Fuels, Petroleum Coke and Carbon Mate
12、rial.Current edition approved Oct. 15, 2008May 1, 2014. Published October 2008 May 2014. Originally approved in 2008. Last previous edition approved in 2008 asD7454 08. DOI: 10.1520/D7454-08.10.1520/D7454-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer
13、 Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the pr
14、evious version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of C
15、hanges section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1upon average particle size and particle size range. Bulk density tends to increase with decreasing coke size. A narrow particle sizerang
16、e for this test minimizes the possibility for variation due to skewing of the test sample toward either screen defining thesample.)6. Apparatus6.1 Pan BalanceAccurate to 0.1 g, with a capacity of 2.0 kg.6.2 Riffle SamplerEnclosed drawer, approximately 380 by 290 by 360 mm, 24-slot.6.3 SievesMeeting
17、Specification E11.6.4 Sieve ShakerElectrical drive with an automatic timer; should have a rotating and tapping action.6.5 Roller CrusherLaboratory type; glass hardened rolls; roll diameter of approximately 150 mm; roll width of approximately150 mm; gap range from 0 to 12.7 mm.6.6 Thickness Gauges (l
18、eaf-type)0.4, 1.0, 1.5, and 4.0 mm.4.0 mm.6.7 Semi-Automated VBD Apparatus, As shown in Fig. 1. See also comments about installation in Annex A1.6.7.1 Borosilicate Glass Powder Funnels8-cm diameter funnels with 1-cm internal diameter and stems about 3.5 cm long.Tips of funnels should be cut at a rig
19、ht (not oblique) angles (see Fig. 1). The distance between the tip of the upper funnel and thebottom of the vibrating bowl should be around 6 mm.6.7.2 Electromagnetic JoggerWith approximately 175- by 250-mm deck, and shall be capable of vibrating at a frequency of60 Hz.6.7.3 Acrylic ClampTo hold cyl
20、inder.6.7.4 Vibrating BowlHaving a diameter of approximately 7.5 cm and a height of 4.0 mm, such as that being used with rotarymicro riffler.6.7.5 Displacement Probe and Reading DevicePermitting continuous monitoring of amplitude vibration.6.7.6 Graduated Cylinder50 mL, with inside diameter approxim
21、ately 23 mm and height approximately 19 cm.6.7.7 Photoelectric Sensor Switch.6.7.8 Control DevicePermitting real-time adjustment of the vibration amplitude and automatic stopping of the feeding devicewhen the coke level reaches the 50-mL mark.6.7.9 Automatic Timer, Clock, or WatchWith a second indic
22、ator.6.7.10 Line Stabilizer (Optional)Use if the noise on the power line is significant and affects the apparatus performance.6.7.11 Round Level.6.7.12 Balance0 to 300 g and sensitive to 0.01 g.FIG. 1 Example of Semi-Automated Apparatus Set-UpD7454 1427. Hazards7.1 Exercise care in the operation of
23、the roll crusher.7.1.1 Wear safety glasses and keep hands clear when feeding material.7.1.2 Turn power off at the source when equipment is opened for cleaning after the grinding operation.8. Sample Preparation8.1 Reduce the original sample volume to about 1 kg.8.2 Manually screen out the natural to
24、4.75 by 1.18 mm and 0.85-mm fraction.8.8 Adjust the roller spacing to 0.5 mm and grind the 0.85-mm fraction. Manually screen out the 0.85 by 0.425-mm fractionand add this fraction into the same plastic bag referred to in 8.7. Discard the 0.85-mmfraction, if present.8.9 Repeat, if necessary, the grin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD74542014RED1330STANDARDTESTMETHODFORDETERMINATIONOFVIBRATEDBULKDENSITYOFCALCINEDPETROLEUMCOKEUSINGASEMIAUTOMATEDAPPARATUS

链接地址:http://www.mydoc123.com/p-525532.html