《ASTM D6869-2003(2011) 4375 Standard Test Method for Coulometric and Volumetric Determination of Moisture in Plastics Using the Karl Fischer Reaction (the Reaction of Iodine with Wa.pdf》由会员分享,可在线阅读,更多相关《ASTM D6869-2003(2011) 4375 Standard Test Method for Coulometric and Volumetric Determination of Moisture in Plastics Using the Karl Fischer Reaction (the Reaction of Iodine with Wa.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6869 03 (Reapproved 2011)Standard Test Method forCoulometric and Volumetric Determination of Moisture inPlastics Using the Karl Fischer Reaction (the Reaction ofIodine with Water)1This standard is issued under the fixed designation D6869; the number immediately following the designatio
2、n indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This method uses the reaction of Iod
3、ine (I2) with water(Karl Fischer Reaction) to determine the amount of moisture ina polymer sample.21.2 This test method is intended to be used for the determi-nation of moisture in most plastics. Plastics containing volatilecomponents such as residual monomers and plasticizers arecapable of releasin
4、g components that will interfere with theI2/water reaction.1.3 This method is suitable for measuring moisture over therange of 0.005 to 100 %. Sample size shall be adjusted toobtain an accurate moisture measurement.1.4 The values stated in SI units are regarded as thestandard.NOTE 1This standard is
5、technically equivalent to ISO 15512 MethodB.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulat
6、ory limitations prior to use.2. Referenced Documents2.1 ISO Document:ISO 15512 PlasticsDetermination of Water Content33. Summary of Test Method23.1 Samples are heated to vaporize water that is transportedby a nitrogen carrier gas to the titration cell. The moisturecollected in the solution within th
7、e titration cell is determinedusing the reaction of water with I2.3.2 Endpoint detection is made by instrumented methods.Determination of the moisture present is made using thereaction of I2with water.3.3 Coulometric instruments use Faradays law to measurethe moisture present with 10.71 Coulombs (C)
8、 of generatingcurrent corresponding to 1 mg of water (2I- I2+2e-).Volumetric instruments measure the volume of solution con-taining I2that is required to keep the current constant.4. Significance and Use4.1 Moisture will affect the processability of some plastics.High moisture content causes surface
9、 imperfections (that is,splay or bubbling) or degradation by hydrolysis. Low moisture(with high temperature) causes polymerization.4.2 The physical properties of some plastics are affected bythe moisture content.5. Interferences5.1 Some compounds, such as aldehydes and ketones,interfere in the deter
10、mination of moisture content using thismethod.6. Apparatus6.1 Heating Unit, consisting of an oven capable of heatingthe sample to approximately 300C, a furnace tube, a tempera-ture control unit, a carrier gas flow meter, and desiccating tubesfor the carrier gas.6.2 Sample Pan (Boat), normally a glas
11、s sample boat or boatmanufactured of a suitable material to transfer the oven heat tothe sample. It is permitted to use aluminum foil as a disposableliner for the sample pan.6.3 Titration Unit, consisting of a control unit, titration cellwith a solution cathode, platinum electrode, and solutionstirr
12、ing capability. This apparatus has the capability to generateor deliver iodine to react stoiciometrically with the moisturepresent in the titration cell. The current or volume required togenerate the iodine converts to micrograms of water present.The percent moisture in the sample is then calculated
13、 based onthe sample weight used and is given as a direct digital readout.6.4 Analytical Balance, capable of weighing 0.1 mg (fourdecimal place balance).1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.70 on Analytical M
14、ethods.Current edition approved Sept. 1, 2011. Published October 2011. Originallyapproved in 2003. Last previous edition approved in 2003 as D6869 - 03.DOI:10.1520/D6869-03R11.2See Appendix X1, History of Reagents Associated With the Karl FischerReaction, for an explanation of coulometric and volume
15、tric techniques as well as anexplanation of the Karl Fischer Reaction and Karl Fischer Reagents.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Consh
16、ohocken, PA 19428-2959, United States.6.5 Glass Capillary (Micropipette), used to measure aknown amount of water, typically 2 mg (2000 g).7. Reagents and Materials7.1 Anode (Generator) Solution, per manufacturers recom-mendation.7.2 Cathode Solution, per manufacturers recommendation.NOTE 2Hydranal o
17、r similar anode and cathode solutions are recom-mended. These reagents do not contain pyridine, are less toxic, and haveno offensive odor.7.3 Silica Gel, granules, approximately 2 mm, desiccant fordrying tube of titration assembly (if applicable).7.4 Special Grease, as supplied by manufacturer for g
18、roundglass joints.7.5 Molecular Sieve, or suitable desiccant (for drying thenitrogen carrier gas stream).7.6 Nitrogen Gas (N2), containing less than 5 g/g of water.7.7 Neutralization Solution, or check solution (per manu-facturers recommendation).8. Hazards8.1 Due to the low quantities of water meas
19、ured, maximumcare shall be exercised at all times to avoid contaminating thesample with water from the sample container, the atmosphereor transfer equipment. Hygroscopic resin samples shall beprotected from the atmosphere.8.2 Due to the high temperatures and the chemicals in-volved in this test meth
20、od, safe lab practices must be followedat all times.9. Sampling, Test Specimens, and Test Units9.1 Unless otherwise agreed upon by interested parties ordescribed in a specification, the material shall be sampledstatistically or the sample shall come from a process that is instatistical control.9.2 S
21、amples that will determine the moisture of a larger lotof material must be taken in such a manner that the moisturecontent will not change from the original material. Samplecontainers must be adequately dried and the environment inwhich sampling is performed must not add additional moistureto the sa
22、mple. Most normal plant or lab operating conditionsare adequate for sampling. The sample container shall beproperly sealed to prevent moisture pick-up before testing.9.3 Samples in many forms, such as molded powder,molded shapes, or re-grind are permitted. It is recommendedthat molded specimens be c
23、ut into smaller parts prior to testing(recommended maximum size 4 by 4 by 3 mm)9.4 Transfer samples quickly from sealed container tobalance to instrument to prevent moisture pick-up.10. Preparation of Apparatus10.1 Assemble the apparatus according to the manufactur-ers instructions. Molecular sieve
24、or suitable desiccant must beused in the drying tubes for the nitrogen carrier gas.10.2 Pour approximately 200 mL(or an amount specified bythe manufacturer) of generator (anode) solution into thetitration cell.10.3 Add 10 mL of cathode solution to the cathode cell.NOTE 3The condition of both anode a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6869200320114375STANDARDTESTMETHODFORCOULOMETRICANDVOLUMETRICDETERMINATIONOFMOISTUREINPLASTICSUSINGTHEKARLFISCHERREACTIONTHEREACTIONOFIODINEWITHWAPDF

链接地址:http://www.mydoc123.com/p-523822.html