《ASTM D6769 D6769M-2002(2010)e1 0625 Standard Guide for Application of Fully Adhered Cold-Applied Prefabricated Reinforced Modified Bituminous Membrane Waterproofing Systems《完全粘结的寒冷.pdf》由会员分享,可在线阅读,更多相关《ASTM D6769 D6769M-2002(2010)e1 0625 Standard Guide for Application of Fully Adhered Cold-Applied Prefabricated Reinforced Modified Bituminous Membrane Waterproofing Systems《完全粘结的寒冷.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6769/D6769M 02 (Reapproved 2010)1Standard Guide forApplication of Fully Adhered, Cold-Applied, PrefabricatedReinforced Modified Bituminous Membrane WaterproofingSystems1This standard is issued under the fixed designation D6769/D6769M; the number immediately following the designation in
2、dicates theyear of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits information was editorially revised in Ju
3、ly 2010.1. Scope1.1 This guide lists application and installation requirementsfor fully adhered, cold-applied, prefabricated modified bitumi-nous membrane waterproofing systems for below-grade orbelow-wearing-surface (such as plaza decks) vertical or hori-zontal applications.1.2 For the purposes of
4、this application guide, the substrateis assumed to be structurally sound, sloped to drain (if newconstruction), and meeting the local building code require-ments. Similarly, the system components are assumed tocomply with all federal, state, and local requirements in effectat the time of installatio
5、n.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewit
6、h the standard.1.4 This guide may involve hazardous materials, operations,and equipment. This standard does not purport to address allof the safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices an
7、d determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:2D1079 Terminology Relating to Roofing and WaterproofingD5295 Guide for Preparation of Concrete Surfaces forAdhered (Bonded) Membrane Waterproofing SystemsD5898 Guide for Details for Adhe
8、red Sheet WaterproofingD5957 Guide for Flood Testing Horizontal WaterproofingInstallations3. Terminology3.1 Definitions:3.1.1 lift, nthe height or length of sheet that may becomfortably handled by the person applying the sheet to avertical surface. This is normally the height of this person, or1.5 t
9、o 2.1 m 5 to 7 ft.3.1.2 skin over, na condition in which the surface of thematerial is no longer tacky, but will move under slight fingerpressure.3.1.3 tack, na condition in which if the surface is touched,there will be a string of material attached to the finger.3.2 For definitions of other terms r
10、elating to waterproofing,see Terminology D1079.4. Significance and Use4.1 This guide outlines general procedures for the storageand application of various prefabricated sheets made usingmodified bituminous materials and intended for use as below-grade and below-wearing-surface waterproofing.4.2 The
11、substrate used for applications described in thisguide shall be concrete or masonry.4.3 This application consists of a prefabricated reinforcedmodified bituminous sheet applied to a suitable substrate usinga bituminous-based, cold-applied adhesive or mastic. Applica-tion rates given are typical for
12、such installations.4.4 This guide is intended to supplement instructions fromdesigners and manufacturers.5. Delivery of Materials5.1 Deliver materials in suppliers original containers andpackaging.1This guide is under the jurisdiction of ASTM Committee D08 on Roofing andWaterproofing and is the dire
13、ct responsibility of Subcommittee D08.22 on Water-proofing and Dampproofing Systems.Current edition approved June 1, 2010. Published July 2010. Originally approvedin 2002. Last previous edition approved in 2002 as D6769 02. DOI: 10.1520/D6769_D6769M-02R10E01.2For referenced ASTM standards, visit the
14、 ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, U
15、nited States.6. Storage and Handling6.1 Store adhesive or mastic in tightly closed originalcontainers under the conditions recommended by the manufac-turer.6.2 Store the modified bituminous sheet in the manufactur-ers original packaging in the manner specified by the manu-facturer. Storage on wood p
16、allets and stacking usually no morethan five rolls high is recommended. Protect against exposureto direct sunlight, precipitation, dust, and other such contami-nants. If inside storage is not available, tarp only with canvastarpaulins; do not use polyethylene or other nonbreathing filmsto cover the
17、packages.7. Safety Precautions7.1 Store flammable materials in a manner that will not posea fire hazard. Solvent-bearing adhesives may be flammable. Donot use flammable materials near an open flame or equipmentthat may produce sparks.8. Environmental Conditions at Time of Application8.1 Environmenta
18、l conditions under which installation mayproceed shall be as recommended by the manufacturer of theadhesive and the sheet. Acceptable weather conditions wouldbe dry enough to allow the mastic to adhere to the substrate,without excessive wind conditions and with surface tempera-tures of the substrate
19、 at 4C 40F or above and rising. Contactthe manufacturer for recommendations whenever weatherconditions raise questions.9. Materials9.1 The waterproofing sheet shall be made using a fabric ofopen weave glass and polyester, or both, which in turn isencapsulated in a chloroprene- and butyl-rubber-modif
20、ied as-phalt that also contains fillers, slow-curing agents, and ultra-violet inhibitors.9.2 The adhesive or mastic shall be made using an asphaltcutback with a Rule-66-type solvent into which has beenblended chloroprene- and butyl-type rubbers for plasticityalong with inorganic fillers and ultravio
21、let inhibitors.10. Substrate Preparations10.1 Contaminants such as dirt, debris, loose materialsmoisture, or surface irregularities that would interfere with thesatisfactory installation and performance of the system shall beremoved. See Guide D5295 for further details about surfacepreparation.11. I
22、nstallation11.1 Apply the adhesive at a rate of 0.5 to 0.6 L/m21.25 to1.5 gal/100 ft2 as a thin coat and allow to dry to a tackycondition before covering with membrane so as to minimizeblistering of the applied membrane. Apply only as muchadhesive as can be covered with membrane before the adhesivel
23、oses its tack. Rub in the membrane by brooming, handrolling,or similar method.11.2 Installation of reinforcement material is required at alltransitions, such as internal and external corners and at staticconcrete construction joints and cracks. Reinforcement is alsorequired where reinforcing bars, p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6769D6769M20022010E10625STANDARDGUIDEFORAPPLICATIONOFFULLYADHEREDCOLDAPPLIEDPREFABRICATEDREINFORCEDMODIFIEDBITUMINOUSMEMBRANEWATERPROOFINGSYSTEMS

链接地址:http://www.mydoc123.com/p-523521.html