ASTM D6331-2014 3335 Standard Test Method for Determination of Mass Concentration of Particulate Matter from Stationary Sources at Low Concentrations &40 Manual Gravimetric Method&.pdf
《ASTM D6331-2014 3335 Standard Test Method for Determination of Mass Concentration of Particulate Matter from Stationary Sources at Low Concentrations &40 Manual Gravimetric Method&.pdf》由会员分享,可在线阅读,更多相关《ASTM D6331-2014 3335 Standard Test Method for Determination of Mass Concentration of Particulate Matter from Stationary Sources at Low Concentrations &40 Manual Gravimetric Method&.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6331 14Standard Test Method forDetermination of Mass Concentration of Particulate Matterfrom Stationary Sources at Low Concentrations (ManualGravimetric Method)1This standard is issued under the fixed designation D6331; the number immediately following the designation indicates the yea
2、r oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method2covers a method for the measurementof
3、particulate matter (dust) concentration in emission gases inthe concentrations below 20 mg/m3standard conditions, withspecial emphasis around 5 mg/m3.1.2 To meet the requirements of this test method, theparticulate sample is weighed to a specified level of accuracy.At low dust concentrations, this i
4、s achieved by:1.2.1 Exercising extreme care in weighing,1.2.2 Extending the sampling time at conventional samplingrates, or1.2.3 Sampling at higher rates at conventional samplingtimes (high-volume sampling).1.3 This test method differs from Test Method D3685/D3685M by requiring the mass measurement
5、of filter blanks,specifying weighing procedures, and requiring monitoring ofthe flue gas flow variability over the testing period. It requiresthat the particulate matter collected on the sample filter have amass at least five times a positive mass difference on the filterblank. High volume sampling
6、techniques or an extension of thesampling time may be employed to satisfy this requirement.1.4 This test method may be used for calibration of auto-mated monitoring systems (AMS). If the emission gas containsunstable, reactive, or semi-volatile substances, the measure-ment will depend on the filtrat
7、ion temperature, and in-stackmethods may be more applicable than out-stack methods forthe calibration of automated monitoring systems.1.5 The values stated in SI units are to be regarded as thestandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with i
8、ts use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1193 Specification for Reagent WaterD1356 Terminology Relating to Sam
9、pling and Analysis ofAtmospheresD2986 Practice for Evaluation of Air Assay Media by theMonodisperse DOP (Dioctyl Phthalate) Smoke Test(Withdrawn 2004)4D3154 Test Method for Average Velocity in a Duct (PitotTube Method)D3631 Test Methods for Measuring Surface AtmosphericPressureD3670 Guide for Determ
10、ination of Precision and Bias ofMethods of Committee D22D3685/D3685M Test Methods for Sampling and Determina-tion of Particulate Matter in Stack GasesD3796 Practice for Calibration of Type S Pitot TubesE1 Specification for ASTM Liquid-in-Glass ThermometersE2251 Specification for Liquid-in-Glass ASTM
11、 Thermom-eters with Low-Hazard Precision Liquids2.2 ISO Standards:5ISO 5725 Precision of test methodsDetermination of re-peatability and reproducibility by inter-laboratory testsISO 9096 Stationary source emissionsDetermination ofconcentration and mass flow rate of particulate material ingas-carryin
12、g ducts. Manual gravimetric method1This test method is under the jurisdiction of ASTM Committee D22 on AirQuality and is the direct responsibility of Subcommittee D22.03 on AmbientAtmospheres and Source Emissions.Current edition approved June 1, 2014. Published July 2014. Originally approvedin 1998.
13、 Last previous edition approved in 2013 as D6331 13. DOI: 10.1520/D6331-14.2This test method is based on ISO/CD 12141.3, “Stationary Source EmissionsDetermination of Mass Concentration of Particulate Matter (Dust) at LowConcentrationsManual Gravimetric Method”, available from International Orga-niza
14、tion for Standardization, Casa Postale 56, CH-1211, Geneva Switzerland.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe AST
15、M website.4The last approved version of this historical standard is referenced onwww.astm.org.5Available from International Organization for Standardization, Casa Postals 56,CH-1211, Geneva, Switzerland.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-295
16、9. United States1ISO 10780 Stationary source emissionsMeasurement ofvelocity and volume flow rate of gas stream in ducts3. Terminology3.1 For definitions of terms used in this test method, refer toTerminology D1356.3.2 Definitions of Terms Specific to This Standard:3.2.1 filtration temperaturethe te
17、mperature of the sampledgas immediately downstream of the filter.3.2.2 high volume samplingsampling at higher rates thantypical in Test Methods D3685/D3685M by using largerdiameter nozzles and higher flow rates to maintain isokineticsampling conditions.3.2.2.1 DiscussionNozzle sizes are typically 20
18、 to 50 mm,with corresponding flow rates from 5 to 50 m3/s.3.2.3 hydraulic diameter, dhdh54 3area of sampling planeperimeter of sampling plane(1)3.2.4 in-stack filtrationfiltration in the stack or duct wherethe filter in its filter housing is placed immediately downstreamof the sampling nozzle and co
19、llects particulate matter in theflue gas, under flue gas conditions.3.2.5 measurement seriessuccessive measurements car-ried out at the same sampling plane and at the same processconditions.3.2.6 out-stack filtrationa sampling technique where thefilter, in its filter housing, collects particulate ma
20、tter undercontrolled temperature conditions outside of the stack or duct.3.2.7 overall blankthe sample taken in a manner identicalto the flue gas test samples, except that the sampling durationis shortened to less than 1 min.3.2.7.1 DiscussionThe overall blank value is expressed inthe same units as
21、the measurement result (for example, mg/m3)using the average sampling volume of the measurement series.The overall blank includes possible deposits on the filter andsurfaces upstream of the filter in contact with the sample gas.3.2.8 particulate matter (dust)solid particles of any shape,structure, o
22、r density dispersed in the gas phase at flue gastemperature and pressure conditions.3.2.8.1 DiscussionIn accordance with the described testmethod, all material that may be collected by filtration underspecified conditions and that remains upstream of the filter andon the filter after drying under sp
23、ecified conditions are consid-ered to be particulate matter. However, for the purposes ofsome regulatory standards, the definition of particulate mattermay extend to condensibles or reacted materials collectedunder specified conditions (for example, specified temperaturelower than the flue gas tempe
24、rature).3.2.9 sampling linethe line in the sampling plane alongwhich the sampling points are located bounded by the innerduct wall.3.2.10 sampling planethe plane normal to the centerlineof the duct at the sampling position.3.2.11 sampling pointthe specific position on a samplingline at which a sampl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD633120143335STANDARDTESTMETHODFORDETERMINATIONOFMASSCONCENTRATIONOFPARTICULATEMATTERFROMSTATIONARYSOURCESATLOWCONCENTRATIONS40MANUALGRAVIMETRICMETHODPDF

链接地址:http://www.mydoc123.com/p-522192.html