ASTM C196-2000(2005) Standard Specification for Expanded or Exfoliated Vermiculite Thermal Insulating Cement《膨胀的或剥落的蛭石隔热水泥标准规范》.pdf
《ASTM C196-2000(2005) Standard Specification for Expanded or Exfoliated Vermiculite Thermal Insulating Cement《膨胀的或剥落的蛭石隔热水泥标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C196-2000(2005) Standard Specification for Expanded or Exfoliated Vermiculite Thermal Insulating Cement《膨胀的或剥落的蛭石隔热水泥标准规范》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 196 00 (Reapproved 2005)Standard Specification forExpanded or Exfoliated Vermiculite Thermal InsulatingCement1This standard is issued under the fixed designation C 196; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification cove
3、rs expanded or exfoliated ver-miculite thermal insulating material in the form of dry cementor plaster, intended to be mixed with a suitable proportion ofwater, applied as a plastic mass, and dried in place, for use asinsulation on surfaces operating at temperatures between100F (38C) and 1800F (982C
4、). The cement shall not beused where it will be exposed to combustion conditions, suchas the hot face lining of a furnace.1.2 The values stated in inch-pound units are to be regardedas the standard. The SI equivalents of inch-pound units aregiven in parentheses and may be approximate.1.3 The followi
5、ng safety hazards caveat pertains only to thetest method portion, Section 10, of this specification. Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpra
6、ctices and determine the applicability of regulatory limita-tions prior to use.1.4 When the installation or use of thermal insulationmaterials, accessories and systems, may pose safety or healthproblems, the manufacturer shall provide the user with appro-priate current information regarding any know
7、n problemsassociated with the recommended use of the companysproducts. The manufacturer shall also recommend protectivemeasures to be employed in the safe utilization of saidproducts.2. Referenced Documents2.1 ASTM Standards:2C 163 Practice for Mixing Thermal Insulating CementSamplesC 166 Test Metho
8、d for Covering Capacity and VolumeChange Upon Drying of Thermal Insulating CementC 168 Terminology Relating to Thermal InsulationC 177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC 353 Test Method for Adhesion of
9、Dried Thermal Insulat-ing or Finishing Cement3C 354 Test Method for Compressive Strength of ThermalInsulating or Finishing Cement3C 356 Test Method for Linear Shrinkage of PreformedHigh-Temperature Thermal Insulation Subjected to Soak-ing HeatC 390 Practice for Sampling and Acceptance of PreformedTh
10、ermal Insulation LotsC 405 Practice for Estimating Consistency of Wet-MixedThermal Insulating CementC 518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC 1058 Practice for Selecting Temperatures for Reportingand Evaluating Thermal Properties of
11、Thermal Insulation3. Terminology3.1 Definitions:3.2 Terminology C 168 shall be considered as applying tothe terms used in this specification.4. Materials and Manufacture4.1 The cement shall be composed predominantly of ex-panded or exfoliated vermiculite, with a suitable proportion ofheat-resistant
12、binder. Asbestos shall not be used as an ingredi-ent or component part of the product.5. Other Requirements5.1 The cement shall conform to the requirements given inTable 1. Conformance shall be based on results of tests onspecimens first mixed with water, according to the ratio forproper troweling c
13、onsistency determined in accordance withSection 10.1This specification is under the jurisdiction of ASTM Committee C-16 onThermal Insulation and is the direct responsibility of Subcommittee C16.20 onHomogeneous Inorganic Thermal Insulations.Current edition approved Sept. 1, 2005. Published October 2
14、005. Originallyapproved in 1944. Last previous edition approved in 2000 as C 196 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary p
15、age onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Qualification Requirements6.1 The following requirements are employed for purposesof initial material or product qualification:6.1.1 Consistency,6.1
16、.2 Compressive strength,6.1.3 Linear shrinkage,6.1.4 Apparent thermal conductivity, and6.1.5 Dry adhesion to steel.7. Sampling7.1 The cement shall be sampled, for the purpose of testsusing one of the following procedures.7.1.1 Inspection Requirements:7.1.1.1 Use Practice C 390. Each bag shall repres
17、ent a unit.7.1.1.2 In a single sampling plan by attributes the accept-ability of a lot will be determined by the number of units ofproduct in the sample that do not conform to the specifications.The acceptable quality level (AQL) and limiting quality level(LQL) of an acceptance sampling plan, expres
18、sed as percent-ages of the units nonconforming, are characteristics of thesampling plan and are not to be viewed as product specifica-tions.7.1.2 Qualification Requirements:7.1.2.1 Use the average of the test data from the number oftest specimens required by the appropriate test method torepresent t
19、he average for the entire lot.7.2 The specimen for test is to be taken from the middle ofa bag, so as to be representative of material from the entire bag.8. Number of Tests and Retests8.1 If the average of the test data obtained using 7.1.2.1 failsto conform to the requirements of this specificatio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC19620002005STANDARDSPECIFICATIONFOREXPANDEDOREXFOLIATEDVERMICULITETHERMALINSULATINGCEMENT 膨胀 剥落

链接地址:http://www.mydoc123.com/p-465979.html