ASTM C166-2005 Standard Test Method for Covering Capacity and Volume Change Upon Drying of Thermal Insulating Cement《隔热水泥在干燥过程中覆盖能力及体积变化的标准试验方法》.pdf
《ASTM C166-2005 Standard Test Method for Covering Capacity and Volume Change Upon Drying of Thermal Insulating Cement《隔热水泥在干燥过程中覆盖能力及体积变化的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C166-2005 Standard Test Method for Covering Capacity and Volume Change Upon Drying of Thermal Insulating Cement《隔热水泥在干燥过程中覆盖能力及体积变化的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 166 05Standard Test Method forCovering Capacity and Volume Change Upon Drying ofThermal Insulating Cement1This standard is issued under the fixed designation C 166; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 Wet covering capacity and volume change upon dryingare often of major importance in the application of therm
3、alinsulating cement. These properties can be easily determined atthe same time that the determinations of dry covering capacityare made. Therefore, the procedures for determining thesethree properties are covered together in this test method.1.2 The values stated in inch-pound units are to be regard
4、edas the standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determin
5、e the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 163 Practice for Mixing Thermal Insulating CementSamplesC 168 Terminology Relating to Thermal Insulation3. Terminology3.1 dry covering capacitythe area covered in “ft2, 1 in. inthickness/100 lb o
6、f dry cement” (m2, 1 cm in thickness/100 kgof dry cement) after the wet cement has been molded and driedto constant weight in accordance with Section 6.3.2 volume change upon dryingthe percentage change involume of the wet molded cement that occurs when the drycement is mixed with the recommended am
7、ount of water,molded, and dried to constant weight in accordance withSection 6.3.3 wet covering capacitythe area covered in “ft2, 1 in. inthickness/100 lb of dry cement (m2, 1 cm in thickness/100 kgof dry cement) when the cement is mixed with the recom-mended amount of water and molded in accordance
8、 withSection 6.3.4 Definitions in Terminology C 168 shall be considered asapplying to the terms used in this test method.4. Significance and Use4.1 This test method is used to determine the wet coveringand volume change upon drying of thermal insulating cement.5. Apparatus5.1 MoldA rigid mold having
9、 inside dimensions of 1 by 8by 30 in. (25.4 by 203 by 726 mm) with one end and one faceopen, and a piece of wood or other suitable material 1 by 112by 778 in. (25.4 by 38.1 by 200 mm) in dimensions for squaringup the end of the test specimen toward the open end of themold.5.2 Wax PaperSheets of wax
10、paper 8 by 30 in. (200 by762 mm) in dimensions.5.3 Engine Oil.5.4 TrowelA 16-in. (about 400-mm) rectangular plaster-ers trowel.5.5 Steel RulesSteel rules 18 and 36 in. (about12 and 1 m)in length accurate to within164 in. (0.5 mm).5.6 Depth GageA depth gage consisting of a rigid,pointed rod approxima
11、tely18 in. (3 mm) in diameter, fittedwith a flat disk about12 in. (13 mm) in diameter which ismoved along the rod either by a sliding action or by means ofthreads.6. Sampling and Mixing6.1 The cement shall be sampled and mixed in accordancewith Practice C 163.7. Procedure7.1 Oil the inside surfaces
12、of the mold well, or line themwith wax paper in order to prevent the cement from sticking tothe sides and to permit convenient removal of the specimen.Then place the mixed cement in the mold.7.2 Trowel the cement in one layer and in two directionslengthwise of the mold without unnecessary compacting
13、, untilthe surface is smooth and flush with the top edges of the mold.Sufficient wet cement shall be used to fill the mold when the1This test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.31 on Chemical andPhysical Pro
14、perties.Current edition approved April 1, 2005. Published April 2005. Originallyapproved in 1941. Last previous edition approved in 1997 as C166 87(1997).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMS
15、tandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.piece of wood or other suitable material is in place in the openend of the mold and in conta
16、ct with the cement, in order tomake a square end and to prevent movement of the cementafter troweling is completed.7.3 Measure the thickness at nine points on the top surfaceof the sample as indicated in Fig. 1.7.4 Make the thickness measurements within an accuracy of62 % by means of a depth gage. C
17、arefully push the point rodof the depth gage through the cement until it comes in contactwith the bottom of the mold. Hold the rod constantly in avertical position and adjust the disk until its flat surface justcomes into contact with the top surface of the cement. Securethe disk to the pin before w
18、ithdrawing the gage from thecement. Determine the thickness of the cement by measuringthe distance from the flat surface of the disk to the pointed endof the rod with a steel rule or by some other suitable scale. Donot fill the indentations in the cement showing the points ofmeasurement, but allow t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1662005STANDARDTESTMETHODFORCOVERINGCAPACITYANDVOLUMECHANGEUPONDRYINGOFTHERMALINSULATINGCEMENT 隔热

链接地址:http://www.mydoc123.com/p-465428.html