ASTM D6047-1999(2003) Standard Test Methods for Rubber Raw--Determination of 5-Ethylidenenorbornene (ENB) or Dicyclopentadiene (DCPD) in Ethylene-Propylene-Diene (EPDM) Terpolymers.pdf
《ASTM D6047-1999(2003) Standard Test Methods for Rubber Raw--Determination of 5-Ethylidenenorbornene (ENB) or Dicyclopentadiene (DCPD) in Ethylene-Propylene-Diene (EPDM) Terpolymers.pdf》由会员分享,可在线阅读,更多相关《ASTM D6047-1999(2003) Standard Test Methods for Rubber Raw--Determination of 5-Ethylidenenorbornene (ENB) or Dicyclopentadiene (DCPD) in Ethylene-Propylene-Diene (EPDM) Terpolymers.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6047 99 (Reapproved 2003)Standard Test Methods forRubber, RawDetermination of 5-Ethylidenenorbornene(ENB) or Dicyclopentadiene (DCPD) in Ethylene-Propylene-Diene (EPDM) Terpolymers1This standard is issued under the fixed designation D 6047; the number immediately following the designa
2、tion indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the det
3、ermination of thecontent of 5-ethylidenenorbornene (ENB) or Dicyclopentadi-ene (DCPD) in ethylene-propylene-diene (EPDM) terpoly-mers. They are applicable to diene contents in the 0.1 to 10mass % range.1.2 ENB and DCPD are dienes introduced in ethylene/propylene rubbers to generate specific cure pro
4、perties. Sincehigh precision for diene content determination has becomevery important, a Fourier Transform Infrared Spectroscopic(FTIR) method was developed. Diene determination wasperformed in the past by a refractive index technique.NOTE 1The procedures for % ENB and % DCPD differ only in thelocat
5、ion in the infrared (IR) of the IR peak being quantified.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theres
6、ponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 297 Test Methods for Rubber ProductsChemicalAnalysisD 1416 Test Methods for Rubber from
7、Synthetic SourcesChemical Analysis3D 3568 Test Methods for RubberEvaluation of EPDM(Ethylene Propylene Diene Terpolymers) Including Mix-tures with OilD 3900 Test Methods for Rubber, RawDetermination ofEthylene Units in EPM (Ethylene-Propylene Copolymers)and EPDM (Ethylene-Propylene-Diene Terpolymers
8、)D 4483 Practice for Determining Precision for Test MethodStandards in the Rubber and Carbon Black IndustriesE 168 Practices for General Techniques of Infrared Quanti-tative AnalysisE 932 Practices for Describing and Measuring Performanceof Dispersive SpectrophotometersE 1421 Practice for Describing
9、 and Measuring Performanceof Fourier Transform Mid-Infrared (FT-MIR) Spectropho-tometers: Level Zero and Level One Tests2.2 ANCHA Document:Specification for Evaluation of Research Quality Analysisof Infrared Spectra43. Summary of Test Methods3.1 The test specimen is molded between two PTFE-coatedalu
10、minum or Mylar sheets. The ENB content is determinedfrom its infrared absorbance at 16811690 cm1, a measure ofENBs exocyclic double bond. The DCPD content is deter-mined from its infrared absorbance at 16051610 cm1,ameasure of DCPDs monocyclic double bond.3.2 The second derivative of the absorbance
11、is calculatedand ratioed to an internal thickness gage. For ENB the resultingsecond derivative peak near 1690 cm1is related to ENB massfraction by calibrating the instrument with known EPDMstandards. For DCPD, the resulting second derivative peak near1610 cm1is related to DCPD mass fraction by calib
12、rating theinstrument with known EPDM standards.3.3 Two main steps are performed in this procedure: auto-matic determination of film thickness and quantification ofdiene.1These test methods are under the jurisdiction of Committee D11 on Rubber andare the direct responsibility of Subcommittee D11.11 o
13、n Chemical Analysis.Current edition approved Nov. 1, 2003. Published December 2003. Originallyapproved in 1996. Last previous edition approved in 1999 as D 604799e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Bo
14、ok of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4“Specification for Evaluation of Research Quality Analysis of Infrared Spec-tra,” Analytical Chemistry, ANCHA, Vol 47, No. 11, p. 94a.1Copyright ASTM International, 100 Barr Harbor Dri
15、ve, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.4 For oil-extended polymers, the oil must be extractedbefore diene is determined. Test Methods D 1416, Sections 67through 74 and Test Methods D 297 can be used for thispurpose.4. Apparatus4.1 Press, Carver-type, capable of pressing f
16、ilms at 150Cand 10 MPa.4.1.1 Primary MoldA stainless steel (SS) mold, 400 mthick, with an opening sized appropriately for the specimenfilm holder described in 4.4 (2 cm by 2 cm). The mold shouldhave approximately the same dimensions as the press platens.4.1.2 Alternate MoldA thinner mold may be used
17、; how-ever, precision may be adversely affected at low diene levels.Test precision should be determined when thinner films areutilized. Example: a 127-m (0.005-in) SS shim with a 15- by35-mm opening may be used for the simultaneous determina-tion of ethylene (Test Methods D 3900) and diene.4.1.3 Alt
18、ernative Mold for Low Molecular Weight (Liquid)EPDM TerpolymersFor liquid EPDM a ring washer 22 mmOD by 16 mm ID (7/8 in OD by 5/8 inch in ID) 400 m thickis used as a apacer between salt plates (NaBr, NaCl) to set afixed path length. The spacer is sized to cover only the outeredge of the salt plate.
19、4.2 Sheets for Molding, either PTFE-coated aluminumsheets or Mylar, Type A, 36 m thick.4.3 Specimen Film HoldersFilms may be molded, cut,and transferred to a film holder. Magnetic film holders areideal. Alternatively, a mold sized to fit in the spectrometerspecimen compartment, with an appropriate s
20、ize opening maybe used to support the film without removal after pressing.4.4 Infrared Fourier Transform SpectrophotometerAn in-strument capable of measuring absorbances in the range40006000 cm1with a transmittance specification (accuracy)of 6 1% T or better. The instrument should be capable ofspect
21、ral resolution of 2 cm1(see “Specification for Evaluationof Research Quality Analysis of Infrared Spectra”). A deuter-ated triglycine sulfate (DTGS) detector should be used. Theinstrument must be operating in accordance with PracticesE 168. Practices E 932 and E 1421 are other important refer-ences.
22、4.4.1 The instrument should be capable of spectral accumu-lation, averaging, and subtracting capabilities. Water is theprimary source of interference in this method. Methods,physical and electronic, that minimize moisture level andvariation are required to obtain the highest precision. Thepreferred
23、method is use of an instrument equipped with a drygas purge and a specimen shuttle, which permits alternatingand repetitive collection of single beam specimen and back-ground spectra (see Section 6). Alternatively, should a speci-men shuttle be unavailable, careful purging of the samplecompartment w
24、ith dry nitrogen can yield satisfactory results.High precision of calibration standard data is indicative ofadequate purging. When moisture interference is not removedby purging, spectral subtraction of water vapor may be used. Aprocedure for further method development is described inAppendix X1.5.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD604719992003STANDARDTESTMETHODSFORRUBBERRAWDETERMINATIONOF5ETHYLIDENENORBORNENEENBORDICYCLOPENTADIENEDCPDINETHYLENEPROPYLENEDIENEEPDMTERPOLYMERSPDF

链接地址:http://www.mydoc123.com/p-521386.html