1、Designation: D 5081 90 (Reapproved 2005)Standard Test Method forAggregate Layer Hiding Power1This standard is issued under the fixed designation D 5081; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method measures the quantity of aggregateneeded to provide an opaque layer under laboratory conditions.Aggregate size Numbers
3、 1 through 8, as listed in ClassificationD 448, may be tested.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is t
4、heresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 702 Practice for Reducing Samples of Aggregate toTesting SizeD75 Practice for Sampl
5、ing AggregatesD 448 Classification for Sizes of Aggregate for Road andBridge ConstructionD 1079 Terminology Relating to Roofing, Waterproofing,and Bituminous Materials3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, see Terminology D 1079.4. Significance and Use4.1 One
6、of the functions of a roofing aggregate is to shieldthe roofing membrane from sunlight that may be destructive tothe roofing membrane. This test method measures the quantityof gravel needed to exclude light under arbitrary laboratoryconditions. This test method need not be performed if theroofing me
7、mbrane is not affected by light exposure.5. Apparatus5.1 Exposure Box, 300-mm2(12-in.2) 6 1 % tray, 90 mm(3.6 in.) minimum deep with an opaque lid.5.2 Light Source150-W floodlight with stand.5.3 Counting TemplateA clear plastic mask with 100-mm2(4-in.2) grid of lines 10 mm (0.4 in. ) apart to result
8、 in 100counting cells.5.4 Light Sensitive PaperRapid printing opaque diazopapers for use in diazo blueline printing machines.5.5 Sample Splitter, riffle type.5.6 Balance, 30-kg (66-lb) capacity, sensitive to 3 3 103%of the capacity.5.7 Diazo Printing Machine.6. Sampling6.1 Follow the sampling recomm
9、endations of Practice D75.7. Procedure7.1 For Roofing BallastFractionate the aggregate, dried to110C (230F ) to constant weight, using a sample splitter, untila 25-kg (55-lb) sample is obtained. Riffle out 2.3-kg (5.1-lb),4.5-kg (9.9-lb), 6.8-kg (15.0-lb), and 9-kg (20.0-lb) 61%specimens in accordan
10、ce with Practice C 702.7.2 For Builtup Roofing AggregateFractionate the driedaggregate sample, using the sample splitter, until a 6-kg(13.4-lb) sample is obtained. Riffle out 1.394-kg (3.073-lb),1.858-kg (4.096-lb), and 2.323-kg (5.12-lb) 61 % specimensin accordance with Practice C 702. These specim
11、ens representaggregate application rates of 15 kg/m2(3.1 lb/ft2).1This test method is under the jurisdiction ofASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.03 onSurfacing and Bituminous Materials for Membrane Waterproofing and Built-upRoofing.Cu
12、rrent edition approved Nov. 1, 2005. Published November 2005. Originallyapproved in 1990. Last previous edition approved in 1999 as D 5081 90 (1999)e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStan
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD508119902005STANDARDTESTMETHODFORAGGREGATELAYERHIDINGPOWER 集料 遮盖 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-518818.html