ASTM D4864-1990(2005) Standard Test Method for Determination of Traces of Methanol in Propylene Concentrates by Gas Chromatography《用气相色谱法测定丙烯浓缩物中痕量甲醇的标准试验方法》.pdf
《ASTM D4864-1990(2005) Standard Test Method for Determination of Traces of Methanol in Propylene Concentrates by Gas Chromatography《用气相色谱法测定丙烯浓缩物中痕量甲醇的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4864-1990(2005) Standard Test Method for Determination of Traces of Methanol in Propylene Concentrates by Gas Chromatography《用气相色谱法测定丙烯浓缩物中痕量甲醇的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4864 90 (Reapproved 2005)An American National StandardStandard Test Method forDetermination of Traces of Methanol in PropyleneConcentrates by Gas Chromatography1This standard is issued under the fixed designation D 4864; the number immediately following the designation indicates the y
2、ear oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Depar
3、tment of Defense.1. Scope1.1 This test method covers the determination of methanolin propylene concentrates in the range of approximately 4 to 40mg/kg (parts-per-million by weight).1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informatio
4、nonly.NOTE 1There is no direct acceptable SI equivalent for screw threads.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine
5、 the applica-bility of regulatory limitations prior to use. Specific warningstatements are given in 11.1.1, 11.2.1, and 12.11.2. Referenced Documents2.1 ASTM Standards:2D 4307 Practice for Preparation of Liquid Blends for Use asAnalytical StandardsE 260 Practice for Packed Column Gas Chromatography3
6、. Terminology3.1 Definitions:3.1.1 propylene concentrateconcentrate containing morethan 90 % propylene.3.2 Definitions of Terms Specific to This Standard:3.2.1 outage tubea length of 6.35-mm (14 in.) outsidediameter SS tubing normally attached to the inside end of avalve used on a pressure sampling
7、cylinder. It is used tofacilitate removal of a set quantity of liquified sample toprevent overpressuring the cylinder.4. Summary of Test Method4.1 A known weight of water is pressured into a samplecylinder containing a known amount of liquified propylene.The contents in the cylinder are shaken and t
8、he water/methanolphase is withdrawn. A reproducible volume of the extract isthen injected into a gas chromatograph (GC) equipped witheither a thermal conductivity or a flame ionization detector.The methanol concentration is calculated from the area of themethanol peak using calibration and extractio
9、n factors obtainedfrom synthetic blends of known methanol content.5. Significance and Use5.1 Methanol is a common impurity in propylene. It canhave a deleterious effect on various processes that use propy-lene as a feedstock.6. Interferences6.1 There are no known interferences using the GC columnsre
10、ferenced in this test method. However, any water-solublecomponent that co-elutes with methanol on any other GCcolumn used would interfere.7. Apparatus7.1 Gas ChromatographAny GC equipped with eitherflame ionization or thermal conductivity detectors with anoverall sensitivity sufficient to detect at
11、least 4 mg/kg ofmethanol.7.2 ColumnAny GC column that separates methanol fromwater, other alcohols, and any co-extracted hydrocarbons.NOTE 2See Table 1 for a suitable list of columns and Fig. 1 and Fig.2 for examples of chromatograms. Also, refer to Practice E 260 for typicalinstructions in preparin
12、g such columns. Alternatively, columns can bepurchased from commercial sources.7.3 Data Handling SystemAny commercially availableGC integrator or GC computer system capable of accuratelyintegrating the area of the methanol peak is satisfactory.1This test method is under the jurisdiction of ASTM Comm
13、ittee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.D0.03 on Propylene.Current edition approved Nov. 1, 2005. Published November 2005. Originallyapproved in 1988. Last previous edition approved in 2000 as D 4864 90 (2000)e1.2For referenced ASTM standards
14、, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19
15、428-2959, United States.7.4 RecorderA strip-chart recorder with a full scale re-sponse of2sorless and a maximum noise rate of 60.3 % fullscale.7.5 Sample Cylinders, 300-mL capacity, stainless steel,Type DOT 3E (12409 kPa (1800 psig) working pressure).7.6 BalancesAny types capable of weighing a 300-m
16、Lsample cylinder and contents accurately to 0.1 g and a 25-mLvolumetric flask and contents accurately to 0.0001 g.7.7 Plug Valve,14-in. male NPT or optionally,14-in. maleNPT to 6.35 mm outside diameter (14 in.) tubing. (See Note 3.)7.8 Shut-off Valves,14-in. male NPT to 6.35 mm outsidediameter (14 i
17、n.) tubing.7.9 Regulating Valves,14-in. male NPT and14-in. male NPTto14-in. female NPT.7.10 Hex Nipple, SS,14-in. male NPT by 102 mm (4 in.)long.7.11 Hex Coupling, SS,14-in. female NPT by 30 mm (1.2in.) long.7.12 Brass Cap,14-in. NPT or optionally, a tube fitting nut,6.35 mm outside diameter (14 in.
18、). (See Note 3.)7.13 Septum, TFE-fluorocarbon lined, 11-mm diameter.7.14 Syringes, 10 and 25 L.8. Reagents and Materials8.1 Methanol, reagent grade or better.8.2 Propylene, 92+ % purity containing 0.2 mg/kg (ppmw)methanol.9. Sampling9.1 The propylene sample shall be in the liquified state andbe repr
19、esentative of the material in the storage tank or processline. Also, for purposes of this method as well as for safetyconsiderations, there must be a vapor space of about 15 % inthe sampling container. It is recommended that samplingTABLE 1 Suitable Gas Chromatographic Columns and TemperaturesAColum
20、nNumberColumn Size, m 3 mm Tubing Type Packing Coating, m ThicknessOven Temperature,C1 1.22 3 6.35 OD SS 15 % Carowax 1540 on 60/80Chromosorb W AW. 902 3.05 3 4.76 OD SS 80/100 mesh Porapak QS . 1003 3.05 3 6.35 OD Cu 10 % Carbowax 1540 on30/60 mesh Chromosorb T. 1204 6.10 3 6.35 OD Cu 10 % Carbowax
21、 1540 on30/60 mesh Chromosorb T. 1205 1.83 3 2 ID glass 10 % Carbowax 20 M on 80/100 Chromosorb W AW. 706153 0.53 ID fused silica . J detector: flame ionization.FIG. 1 Chromatograms of Water/Methanol Standard and Water/Methanol/Propylene ExtractANOTEColumn used: No. 4 of Table 1; detector: thermal c
22、onductivity.FIG. 2 Chromatogram of Water/Methanol/Propylene ExtractD 4864 90 (2005)2cylinders of the type listed in Section 7 be used. They can beequipped with an outage tube to effect the 15 % vapor spacerequirement.10. Preparation of Apparatus10.1 Prepare a water injection device. A suitable devic
23、e isshown in Fig. 3. However, any other device that will deliverfrom 8 to 15 g of water can be used.10.2 Prepare a 300-mL sample cylinder for use as a metha-nol cylinder, as shown in Fig. 4. (This cylinder must notcontain an outage tube.) Drilla3to4mm(approximately18in.) hole in a14-in. NPT brass ca
24、p, insert an 11-mm septum intoit, and screw it onto the plug valve.NOTE 3As an alternative, the cylinder can be equipped with14-in.male NPT to a 6.35-mm (14-in.) outside diameter tubing plug valve. Thena 6.35-mm tube fitting nut can be used with the septum, thus avoiding thenecessity of drilling a b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD486419902005STANDARDTESTMETHODFORDETERMINATIONOFTRACESOFMETHANOLINPROPYLENECONCENTRATESBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-518248.html