ASTM D4773-2002(2012) Standard Test Method for Purity of Propylene Glycol Monomethyl Ether Dipropylene Glycol Monomethyl Ether and Propylene Glycol Monomethyl Ether Acetate《丙二醇单甲醚、.pdf
《ASTM D4773-2002(2012) Standard Test Method for Purity of Propylene Glycol Monomethyl Ether Dipropylene Glycol Monomethyl Ether and Propylene Glycol Monomethyl Ether Acetate《丙二醇单甲醚、.pdf》由会员分享,可在线阅读,更多相关《ASTM D4773-2002(2012) Standard Test Method for Purity of Propylene Glycol Monomethyl Ether Dipropylene Glycol Monomethyl Ether and Propylene Glycol Monomethyl Ether Acetate《丙二醇单甲醚、.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4773 02 (Reapproved 2012)Standard Test Method forPurity of Propylene Glycol Monomethyl Ether, DipropyleneGlycol Monomethyl Ether, and Propylene GlycolMonomethyl Ether Acetate1This standard is issued under the fixed designation D4773; the number immediately following the designation ind
2、icates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determinatio
3、n by gaschromatography of propylene glycol monomethyl ether (PM),dipropylene glycol monomethyl ether (DPM), and propyleneglycol monomethyl ether acetate (PMA).NOTE 1Propylene glycol monomethyl ether (PM) is a mixture of twoisomers: 1-methoxy-2-propanol and 2-methoxy-1-propanol.Dipropylene glycol mon
4、omethyl ether (DPM) is a mixture of fourisomers: 1-(2-methoxy-1-methylethoxy)-2-propanol is one of the majorisomers.Propylene glycol monomethyl ether acetate (PMA) is a mixture of twoisomers: 1-methoxy-2-acetoxypropane and 2-methoxy-1-acetoxypropane.1.1.1 This test method covers the determination of
5、 PM inthe range from 98 to 100 %, and DPM in the range from 0.08to 0.6 %.1.1.2 This test method covers the determination of DPM inthe range from 98 to 100 %, PM in the range from 0.05 to0.3 %, and tripropylene glycol monomethyl ether (TPM) in therange from 0.06 to 0.3 %.1.1.3 This test method covers
6、 the determination of PMA inthe range from 99 to 100 %, and PM in the range from 0.03 to1.0 %.1.2 Water and acid cannot be determined by this test methodand must be measured in accordance with Test Methods D1364and D1613, and the results used to normalize the chromato-graphic data.1.3 The following
7、applies to all specified limits in thisstandard; for purposes of determining conformance with thisstandard, an observed value or a calculated value shall berounded off “to the nearest unit” in the last right-hand digitused in expressing the specification limit, in accordance withthe rounding-off met
8、hod of Practice E29.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 For hazard information and guidance, see the suppliersMaterial Safety Data Sheet.1.6 This standard does not purport to address all of thesafety concerns
9、, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1364 Test Method for Water in Volatile Sol
10、vents (KarlFischer Reagent Titration Method)D1613 Test Method for Acidity in Volatile Solvents andChemical Intermediates Used in Paint, Varnish, Lacquer,and Related ProductsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Specifications3. Summary of Test Method3.1
11、A representative sample of PM, DPM, or PMA contain-ing the appropriate internal standard is injected into a capillarygas chromatograph and the components are detected with aflame ionization detector. Quantification is made by peak areameasurement using internal standardization and a computingintegra
12、tor.4. Significance and Use4.1 This test method is used to determine the purity of PM,DPM, and PMAby subtracting calculated total impurities from100 %.4.2 This test method is used to determine the quantity ofresidual glycol ether present in PMA.4.3 This test method is used for identifying various im
13、pu-rities in PM, DPM, and PMA.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.35 on Solvents, Plasticizers, and Chemical Intermediates.Current edition approved July 1, 2012
14、. Published September 2012. Originallyapproved in 1988. Last previous edition approved in 2007 as D4773 02 (2007).DOI: 10.1520/D4773-02R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
15、 information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Apparatus5.1 ChromatographAny programmed
16、 temperature gaschromatograph designed or modified for use with capillarycolumns. The chromatograph must also be equipped with aflame ionization detector.5.2 ColumnCapillary, 5 m thick film, 10 m by 0.32 mminside diameter, fused silica coated, with 5 % phenyl methylsilicon liquid phase.5.3 Syringe10
17、 L or equivalent to introduce a representa-tive sample onto the column.5.4 Computing Integator, capable of peak summation and abaseline construction.5.5 Analytical Balance, capable of measuring 0.1 mg.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. U
18、nless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficient
19、ly high purity to permit its use without lessening theaccuracy of the determination.6.2 Gases:6.2.1 Carrier GasHelium, with a minimum purity of99.95 mol % for use with a flame ionization detector.6.2.2 Detector GasHydrogen with a minimum purity andair for use with the flame ionization detector.6.3 S
20、tandards for Calibration and Identification:6.3.1 N-Butyl AcetateDistilled-in-glass purity for use asan internal standard in determination of PMA.6.3.2 MonochlorobenzeneDistilled-in-glass purity for useas an internal standard in determination of PM and DPM.6.3.3 Dipropylene Glycol Monomethyl Ether (
21、DPM)Purity should be determined and the standard solution adjustedfor this purity.6.3.4 Propylene Glycol Monomethyl Ether (PM)Purityshould be determined and the standard solution adjusted forthis purity.6.3.5 Propylene Glycol Monomethyl Ether Acetate (PMA)Purity should be determined and the standard
22、 solution adjustedfor this purity.6.3.6 Tripropylene Glycol Monomethyl Ether (TPM)Purity should be determined and the standard solution adjustedfor this purity.7. Calibration and Standardization7.1 Preparation of Calibration Standard Solution:7.1.1 Propylene Glycol Monomethyl Ether (PM)Weighinto a v
23、ial to within 0.1 mg, 10.00 g of PM calibration standard(see 6.3.4) and 0.02 g of DPM. Check these reagents for purityunder the conditions used in the procedures and, if interferingcompounds are present, adjustment must be made in preparingthe standard.7.1.2 Dipropylene Glycol Monomethyl Ether (DPM)
24、Weigh into a vial to within 0.1 mg, 10.00 g of DPM calibrationstandard (see 6.3.3), 0.02 g of PM calibration standard (see6.3.4), and 0.02 g of TPM (see 6.3.6). Check these reagents forpurity under the conditions used in the procedure and, ifinterfering compounds are present, adjustment must be made
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD477320022012STANDARDTESTMETHODFORPURITYOFPROPYLENEGLYCOLMONOMETHYLETHERDIPROPYLENEGLYCOLMONOMETHYLETHERANDPROPYLENEGLYCOLMONOMETHYLETHERACETATE

链接地址:http://www.mydoc123.com/p-517941.html