ASTM D3923-1994(2003)e1 Standard Practices for Detecting Leaks in Reverse Osmosis Devices《反渗透装置中检测渗漏的标准实施规程》.pdf
《ASTM D3923-1994(2003)e1 Standard Practices for Detecting Leaks in Reverse Osmosis Devices《反渗透装置中检测渗漏的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3923-1994(2003)e1 Standard Practices for Detecting Leaks in Reverse Osmosis Devices《反渗透装置中检测渗漏的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3923 94 (Reapproved 2003)e1Standard Practices forDetecting Leaks in Reverse Osmosis Devices1This standard is issued under the fixed designation D 3923; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEAn editorial change was made in 10.1 in June 2003.1. Scope1.1 These practices cover detecting leaks in which there is adirect c
3、ommunication between the feed or concentrate, or both,and the permeate. Several types of leaks are possible with thevarious configurations of reverse-osmosis devices.1.2 Types of Leaks:1.2.1 With hollow-fiber devices, feed or concentrate leak-age, or both, into the permeate stream by leaks through t
4、he tubesheet and past the tube sheet O-ring are possible. “Leaks”caused by broken fibers are not covered by these practices.1.2.2 With spiral-wound devices, leaks may occur throughdamage of the membrane surface itself by punctures orscratches, by glue-line failure, and by O-ring leaks on producttube
5、 interconnectors.1.2.3 With tubular devices, leaks due to membrane damage,tube end seal leaks, and leaks from broken tubes or productheaders are possible.1.3 Three leak test practices are given as follows:SectionsPractice ATube Sheet and O-Ring Leak Test for HollowFiber Devices6to9Practice BVacuum T
6、est for Spiral Wound Devices 10 to 12Practice CDye Test for Spiral Wound and Tubular Devices 13 to 181.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and hea
7、lth practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 1129 Terminology Relating to Water2D 1193 Specification for Reagent Water2D 4194 Test Methods for Operating Characteristics of Re-verse Osmosis Devices3E60 Practice for M
8、olecular Absorption SpectrophotometricMethods for Chemical Analysis of Metals, Ores, andRelated Materials4E 275 Practice for Describing and Measuring Performanceof Ultraviolet, Visible, and Near Infrared Spectrophotom-eters53. Terminology3.1 For definitions of terms used in these practices, refer to
9、Terminology D 1129.3.2 For descriptions of terms relating to reverse osmosis,refer to Test Methods D 4194.3.3 Definitions of Terms Specific to This Standard:3.3.1 leakbypassing of the intact membrane from thefeed side to the permeate side.4. Summary of Practice4.1 The hollow-fiber device being teste
10、d is operated at lowpressure with the permeate tube sheet exposed (the fiber bundleis held in place by a “spider” device designed for the specificmodel under test). Any significant leak in the tube sheet orO-ring seal is detected visually by inspection.5. Significance and Use5.1 These practices may
11、be used to determine whether areverse-osmosis device is free of leaks if the mechanicalintegrity of the device is to be confirmed. They may also beused to detect leaks in reverse-osmosis devices whose operat-ing performance indicates a possible leak. These practices maybe used for either new or used
12、 devices.6. Apparatus6.1 “Spider” Device, designed for the specific model ofhollow-fiber device being tested, is available from the supplier.The “spider” is designed to take the place of the permeate endplate and permeate collection grid/block while securing thefiber bundle from movement. This allow
13、s visual observationduring low-pressure operation with the fiber bundle retained inits original position.1These practices are under the jurisdiction of ASTM Committee D19 on Waterand are the direct responsibility of Subcommittee D19.08 on Membranes and IonExchange Materials.Current edition approved
14、June 10, 2003. Published July 2003. Originallyapproved in 1980. Last previous edition approved in 1998 as D 3923 94 (1998).2Annual Book of ASTM Standards, Vol 11.01.3Annual Book of ASTM Standards, Vol 11.02.4Annual Book of ASTM Standards, Vol 03.05.5Annual Book of ASTM Standards, Vol 03.06.1Copyrigh
15、t ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Purity of Reagents7.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of the Committee on An
16、alyticalReagents of the American Chemical Society, where suchspecifications are available.6Other grades may be used,provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determinations.7.2 Unless otherwise indicated, re
17、ferences to water shall beunderstood to mean Type III reagent water conforming toSpecification D 1193.PRACTICE ATUBE SHEET AND O-RING LEAKTEST FOR HOLLOW FIBER DEVICES8. Scope8.1 This practice is applicable to detecting feed or concen-trate leakage, or both, through the tube sheet and past the tubes
18、heet O-ring into the permeate in hollow-fiber devices.9. Procedure9.1 Connect a centrifugal pump with 1.4 MPa (200 psig)capability and a throttling valve to the feed port of thehollow-fiber device. Install a pressure gage and valve on theconcentrate port of the reverse-osmosis device.9.2 Remove the
19、permeate end plate and auxiliary equipmentin accordance with the suppliers instructions to expose theface of the permeate tube sheet.9.3 Install a “spider” device (available from supplier) de-signed for the specific model under test and secure the “spider”with the snap or segmented ring that held th
20、e permeate endplate in place.9.4 Place the hollow-fiber device in the horizontal positionand orient the open concentrate line to the highest point (12oclock). Allow water to flow through the device at linepressure (approximately 350 kPa; 50 psig) to remove anytrapped air in the device. Slowly close
21、concentrate line valve topressurize the unit to 350 kPa (50 psig). While standing clearof the tube sheet, start the pump and increase pressure slowlyuntil a maximum pressure of 1.05 MPa (150 psig) is obtained.Proceed with the tube sheet inspection.NOTE 1The leak test should take approximately 15 min
22、 to determinethe integrity of the tube sheet and tube sheet O-ring.9.5 Examine for leaks by observing the product water as itexits the tube sheet face. If leaks do not exist, the product waterappears to ooze out from the tube sheet face. However, if asignificant leak is present in the tube sheet or
23、O-ring seal, aforceful spray or stream will be observed. During inspection,rotate the device 180 to examine the lower portion of the tubesheet for leaks. This is necessary since leaks in the lowerportion of the tube sheet are not easily discernible because ofthe accumulation of product water.9.6 Shu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD392319942003E1STANDARDPRACTICESFORDETECTINGLEAKSINREVERSEOSMOSISDEVICES 反渗透 装置 检测 渗漏 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-515813.html