ASTM D1826-1994(2010) Standard Test Method for Calorific (Heating) Value of Gases in Natural Gas Range by Continuous Recording Calorimeter《用连续记录量热器测定天燃气范围中煤气热值的标准试验方法》.pdf
《ASTM D1826-1994(2010) Standard Test Method for Calorific (Heating) Value of Gases in Natural Gas Range by Continuous Recording Calorimeter《用连续记录量热器测定天燃气范围中煤气热值的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1826-1994(2010) Standard Test Method for Calorific (Heating) Value of Gases in Natural Gas Range by Continuous Recording Calorimeter《用连续记录量热器测定天燃气范围中煤气热值的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1826 94 (Reapproved 2010)Standard Test Method forCalorific (Heating) Value of Gases in Natural Gas Range byContinuous Recording Calorimeter1This standard is issued under the fixed designation D1826; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination with thecontinuous recording calor
3、imeter (Note 1) of the total calorific(heating) value of fuel gas produced or sold in the natural gasrange from 900 to 1200 Btu/standard ft3.NOTE 1An extensive investigation of the accuracy of the Cutler-Hammer recording gas calorimeter, when used with gases of high heatingvalue, was made by the Nat
4、ional Bureau of Standards in 1957 under aresearch project sponsored by the American Gas Association.1.2 The subjects covered in this test method appear in thefollowing sections:SectionsAir-Gas Ratio Test 11Apparatus 5Basis of Measurement 14Cold Balance Test 10Compensation of Complicating Factors 13C
5、ondition of Gas Sample 7Definitions 2Installation of Apparatus 6Maintenance Appendix X1Operating Precautions Appendix X2Operation and Checking of Apparatus 9Precision 15Scope 1Significance and Use 4Standardization of Calorimeter 12Standardization, Preliminary, of Calorimeter by Hydrogen 8Summary of
6、Test Method 31.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
7、 Terminology2.1 Definitions of Terms Specific to This Standard:2.1.1 The most important terms used in connection with thedetermination of the calorific value of gaseous fuels in record-ing calorimetry are as follows:2.1.2 British Thermal Unit, or Btuis the defined Interna-tional Tables British therm
8、al unit (symbol Btu).NOTE 2The defining relationships are:(a) 1 Btulb1= 2.326 Jg1(exact)(b) 1 lb = 453.592 37 g (exact).By these relationships, 1 Btu = 1 055.055 852 62 J (exact). For mostpurposes, the value rounded to 1 Btu = 1 055.056 J is adequate.2.1.3 combustion airair used for combustion, a to
9、tal ofthe portion mixed with the gas as primary air and the airsupplied around the burner tube as secondary air (theoreticalair plus excess air).2.1.4 flue gasesthe products, of combustion remaining inthe gaseous state, together with any excess air.2.1.5 heat-absorbing airthe heat exchange medium us
10、edto absorb the heat of combustion derived from the burning ofgaseous fuel.2.1.6 saturated basisthe expressed total calorific value ofa gas when it is saturated with water vapor at standardtemperature and pressure; 1 ft3of this gas is equivalent in drygas content to 0.9826 ft3of dry gas at the stand
11、ard temperatureof 60F and standard pressure of 14.73 psia.NOTE 3The definitions given in 2.1.6 and 2.1.10 are for total calorific(heating) values per standard cubic foot of gas. The definitions corre-sponding to any other unit quantity of gas are obtained by substituting thename of the desired unit
12、in place of the term “standard cubic foot” in thedefinitions. Methods of calculating calorific (heating) values per cubicfoot of gas under any desired conditions of pressure, temperature, andwater vapor content are specified in Section 14.2.1.7 standard cubic foot of gasthe quantity of any gasthat a
13、t standard temperature and under standard pressure willfill a space of 1 ft3when in equilibrium with liquid water.2.1.8 standard pressureis 14.73 psia.1This test method is under the jurisdiction ofASTM Committee D03 on GaseousFuels and is the direct responsibility of Subcommittee D03.03 on Determina
14、tion ofHeating Value and Relative Density of Gaseous Fuels.Current edition approved May 1, 2010. Published July 2010. Originally approvedin 1961. Last previous edition approved in 2003 as D1826 94 (2003). DOI:10.1520/D1826-94R10.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
15、 Conshohocken, PA 19428-2959, United States.NOTE 4This is the pressure base adopted by the American NationalStandards Institute in 1969 (Z132.1). According to Daltons law, this isequivalent to stating that the partial pressure of the gas is:14.73 0.256 36 = 14.473 64 psiawhere 0.256 36 is the vapor
16、pressure of water in psia at 60F.2.1.9 standard temperature60F, based on the interna-tional practical temperature scale of 1968.2.1.10 total calorific value (gross heating value, higherheating value)of a gas is the number of British thermal unitsevolved by the complete combustion at constant pressur
17、e ofone standard cubic foot of gas with air, the temperature of thegas, air, and products of combustion being 60F, and all thewater formed by the combustion reaction being condensed tothe liquid state.3. Summary of Test Method3.1 The heating value is determined by imparting all of theheat obtained f
18、rom the combustion of the test gas to a streamof air and measuring the rise in temperature of the air. Thestreams of test gas and heat absorbing air are maintained infixed volumetric proportion to each other by metering devicessimilar to the ordinary wet test meters geared together anddriven from a
19、common electric motor. The meters are mountedin a tank of water, the level of which is maintained and thetemperature of which determines the temperature of the enter-ing gas and air.3.2 The flue gas resulting from combustion of the gas(combustion products plus excess combustion air) is keptseparate
20、from the heat-absorbing air and is cooled to a fewdegrees above the initial temperature of gas and air. The waterformed in the combustion is practically all condensed to theliquid state. Consequently, the temperature rise produced in theheat-absorbing air is directly proportional to the heating valu
21、eof the gas. Since all the heat from the combustion of the testgas sample, including the latent heat of vaporization of thewater vapor formed in the combustion, is imparted to theheat-absorbing air, the calorimeter makes a direct determina-tion of total heating value. The temperature rise is measure
22、d bynickel resistance thermometers and is translated into Btu perstandard cubic foot.4. Significance and Use4.1 This test method provides an accurate and reliablemethod to measure the total calorific value of a fuel gas, on acontinuous basis, which is used for regulatory compliance,custody transfer,
23、 and process control.5. Apparatus5.1 The recording calorimeter (Note 5) consists of twomajor units; the tank unit or calorimeter proper, Fig. 1, Fig. 2,and Fig. 3, in which the heating value of the test gas sample ismeasured; and the recording unit which translates the heatmeasurements into an indic
24、ation of calorific (heating) valueand records it graphically on a strip chart recorder or digitallyif the new SMART-CAL is used (Note 6).NOTE 5The previous specified pressure base was the absolute pres-sure of a column of pure mercury 30 in. in height at 32F and understandard gravity (32.174 ft/s2).
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD182619942010STANDARDTESTMETHODFORCALORIFICHEATINGVALUEOFGASESINNATURALGASRANGEBYCONTINUOUSRECORDINGCALORIMETER

链接地址:http://www.mydoc123.com/p-510524.html