1、Designation: D1511 10 D1511 12Standard Test Method forCarbon BlackPellet Size Distribution1This standard is issued under the fixed designation D1511; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numb
2、er in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the pellet size distribution of carbon black.1.2 The values stated in SI units are to be regar
3、ded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and deter
4、mine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1799 Practice for Carbon BlackSampling Packaged ShipmentsD1900 Practice for Carbon BlackSampling Bulk ShipmentsD4483 Practice for Evaluating Precision for Test Method Standards in the Rubber and
5、Carbon Black Manufacturing IndustriesD5817 Practice for Carbon Black, PelletedReduction, Blending, and Drying of Gross Samples for TestingE11 Specification for Woven Wire Test Sieve Cloth and Test Sieves3. Summary of Test Method3.1 A 100 g sample of carbon black is shaken for 1 min in a sieve shaker
6、 to sortseparate the pellets in a sieve assembly composedof the following sieve sizes: No. 10 (2000 m), No. 18 (1000 m), No. 35 (500 m), No. 60 (250 m), No. 120 (125 m), andpan. The mass by size with specified series of sieve screens arranged with progressively smaller openings. The percentage, byma
7、ss, of carbon black retained on each sieve determines is weighed to calculate the pellet size distribution.4. Significance and Use4.1 The variation in the size of the pellets may relate to the level of dispersion and to the ease of handling. Due to the manyother variables that influence dispersion a
8、nd handling, the significance of pellet size must be determined by the user.5. Apparatus5.1 Riffle Sample Splitter as specified in Practice D5817.5.2 Balance with a sensitivity of 0.1 g.5.3 SievesU.S. Standard Sieves or equivalent, conforming to Specification E11. Sieve Nos. 10, 18, 35, 60, and 120,
9、 havingopenings respectively of 2000, 1000, 500, 250, and 125 m, shall be used. The sieves shall be 25 mm (1 in.) in height and 200mm (8 in.) in diameter.5.4 Bottom receiver pan and top sieve cover.5.5 Sieve ShakerAny equipment that will vibrate or shake a stack of sieves in a manner that will allow
10、 the pellets to separateinto size fractions without excessive pellet breakage. The following three types of shakers have been found satisfactory fordetermining the pellet size distribution of pelleted carbon black.1 This test method is under the jurisdiction of ASTM Committee D24 on Carbon Black and
11、 is the direct responsibility of Subcommittee D24.51 on Carbon Black PelletProperties.Current edition approved July 1, 2010June 1, 2012. Published August 2010August 2012. Originally approved in 1957. Last previous edition approved in 20062010 asD1511 00 (2006).D1511 10. DOI: 10.1520/D1511-10.10.1520
12、/D1511-12.2 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is int
13、ended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the curr
14、ent versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.5.1 Mechanical Sieve Shaker3The Ro-Tap Siever imparts Mechanical Sieve Shaker shall impart a u
15、niform rotary andtapping motion to a stack of sieves as described in 5.3. The shaker machine shall be powered with an electric motor producing181 to 183 rads/s (1725 to 1750 r/min). This will produce 140 to 160 raps/min and 280 to 320 rotary motions/min. constantoscillation to the sieve stack provid
16、ing 280 to 320 rotary motions/min and 140 to 160 taps per minute. The cover plate shall befitted with a cork stopper that shall extend 3 to 9 mm (18 to 38 in.) above the metal recess. Materials other than cork, such as rubberor wood, are unacceptable. The heightamplitude of the RoTap hammer shall be
17、 set at 3.30 cm 6 0.15 cm (15/16(1516 in. 61/16116 in.).5.5.2 Vibratory Siever4The Retsch Sieve Shaker AS200 has variable timer and amplitude settings. When set at 3 min and 0.5amplitude, the AS200 provides satisfactory results. It accommodates a stack of sieves as described in 5.3.5.5.3 Automatic S
18、ieve Shaker5The Gradex 2000 automatically performs all of the required steps including the weighing of thesample and the individual fractions retained on each sieve. The equipment consists of a balance, autofeed system, electric motorthat imparts a uniform rotary motion, pneumatically operated rods
19、to provide the tapping action, and computer and software torecord and perform analyses. Shake time of 1 min provides satisfactory test results. The test sieves are described in 5.3.NOTE 1Top sieve cover is not needed for the Gradex 2000.NOTE 2The Gradex is supplied with one standard tapping rod. It
20、is recommended that two additional tapping rods be installed to provide additionaltapping action.6. Sampling6.1 Lot samples shall be taken in accordance with Practices D1799 or D1900.6.2 Practice D5817 shall be used for blending or reducing samples.7. Procedure7.1 Prepare carbon black for testing as
21、 noted in Section 6.NOTE 3It is not good practice to weigh out the test portion by pouring it directly from the sample container since the smaller pellets will tend to remainin the container while the larger pellets pour out first. Dipping the black from the container is the preferred technique.7.2
22、Prepare the sieve assembly by stacking the sieves in the following order from bottom to top: Bottom receiver pan, No. 120,No. 60, No. 35, No. 18, No. 10, and top sieve cover.NOTE 4Top sieve cover is not needed for the Gradex 2000.7.3 Mechanical and Vibratory Sieve Shakers7.3.1 Weigh 100.0 g of carbo
23、n black.7.3.2 Transfer weighed carbon black to the top sieve.7.3.3 Install the sieve cover and transfer the sieve assembly to the shaker. The stack in the shaker should be adjusted to eliminatelooseness.7.3.4 Start the shaker and allow it to shake as noted below:7.3.4.1 Mechanical Shaker1 min with h
24、ammer operating.7.3.4.2 Vibratory Shaker3 min and 0.5 mm amplitude.7.3.5 Remove the sieve assembly from the apparatus and weigh individually the carbon black retained on each sieve and bottomreceiver pan to the nearest 0.1 g.7.3.6 Record the data and calculate as noted in Section 8.7.4 Automatic Sie
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD15112012STANDARDTESTMETHODFORCARBONBLACKPELLETSIZEDISTRIBUTION 炭黑 球状 尺寸 分布 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509944.html