ASTM D1000-2010 Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications《电气和电子设备用压敏粘合剂涂层胶带的标准试验方法》.pdf
《ASTM D1000-2010 Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications《电气和电子设备用压敏粘合剂涂层胶带的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1000-2010 Standard Test Methods for Pressure-Sensitive Adhesive-Coated Tapes Used for Electrical and Electronic Applications《电气和电子设备用压敏粘合剂涂层胶带的标准试验方法》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1000 10An American National StandardStandard Test Methods forPressure-Sensitive Adhesive-Coated Tapes Used forElectrical and Electronic Applications1This standard is issued under the fixed designation D1000; the number immediately following the designation indicates the year oforiginal
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defens
3、e.1. Scope*1.1 These test methods cover procedures for testingpressure-sensitive adhesive-coated tapes to be used as electri-cal insulation. These tapes are classified as follows:1.1.1 Class 1Non-elastomeric backings made from mate-rials such as:Paper, flat or creped,Fabric, uncoated or coated,Cellu
4、lose ester films,Polyethylene terephthalate (polyester) films,Fluorocarbon polymer films,Composite filament films,Polyamide films,Polyimide films, andCombinations thereof.1.1.2 Class 2Elastomeric backings that are characterizedby both high stretch and substantial recovery. These backingsare made fro
5、m materials such as:Vinyl chloride and co-polymers,Vinylidene chloride and co-polymers, andPolyethylene and co-polymers.1.2 Test laminates of Class 1 and Class 2 backings accord-ing to Class 1 test methods.1.3 This standard does not purport to address all of thesafety concerns, if any, associated wi
6、th its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardssee Section 3.1.4 The procedures appear in the sections indicated belowand in alphabetic
7、al order:Adhesion Strength to Steel and Backing at Room Temperature 46-53Adhesion Strength to Steel and Backing at Low Temperatures 46-53Bond Strength After Solvent Immersion 110-115Breaking Strength and Elongation at Room Temperature 37-45Breaking Strength and Elongation at Low Temperatures 37-45Co
8、nditioning 6-8Curling and Twisting 140-146Dielectric Breakdown Voltage 83-90Effect of Accelerated Aging on High-Temperature Tapes 97-103Flagging 66-76Flammability 104-109Hazards/Precautions 3Insulation Resistance at High Humidity 91-96Length of Tape in a Roll 28-36Oil Resistance 116-122Puncture Resi
9、stance 123-128Resistance to Accelerated Aging (Heat and Moisture) 129-139Sampling 4Specimen Preparation 5Thermosetting Properties 77-82Thickness 21-27Unwind Force at Room Temperature 54-65Unwind Force at Low Temperatures 54-65Width 11-20NOTE 1These procedures apply to both Class 1 and Class 2 tapese
10、xcept as noted above.1.5 The values stated in SI units are the standard, unlessotherwise noted. If a value for measurement is followed by avalue in inch-pound or English units in parentheses, the secondvalue may only be approximate and is for information only.The first stated value is the preferred
11、unit.NOTE 2These test methods are similar to IEC 604543, but may differsometimes in some details.1.6 This is a firetest response standard.2. Referenced Documents2.1 ASTM Standards:2A167 Specification for Stainless and Heat-ResistingChromium-Nickel Steel Plate, Sheet, and StripD149 Test Method for Di
12、electric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD257 Test Methods for DC Resistance or Conductance ofInsulating MaterialsD295 Test Methods for Varnished Cotton Fabrics Used forElectrical Insulation1These test methods are under
13、the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct responsibility ofSubcommittee D09.07 on Flexible and Rigid Insulating Materials.Current edition approved Jan. 1, 2010. Published February 2010. Originallyapproved in 1948. Last previous edition
14、 approved in 2009 as D100009. DOI:10.1520/D1000-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summar
15、y of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.D374 Test Methods for Thickness of Solid Electrical Insu-lationD1711 Terminology Relating to Electrical InsulationD3487 Specifica
16、tion for Mineral Insulating Oil Used inElectrical ApparatusD5032 Practice for Maintaining Constant Relative Humid-ity by Means of Aqueous Glycerin SolutionsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 IEC Standard:IEC 60454-3 Specification for P
17、ressure-Sensitive AdhesiveTapes for Electrical Purposes33. Hazards3.1 The following specific substances are flammable liq-uids. Do not use them in the vicinity of open flames orelectrical contacts: acetone (see 50.1 and 94.1), heptane (see50.1 and 94.1), and toluene (see 70.6). They must be stored i
18、nclosed containers, and it is imperative to clean apparatus in awell-ventilated area.3.2 As toluene is a toxic substance, use toluene only whereadequate ventilation is provided and in such manner as to avoidany absorption through the skin (see 70.6).3.3 WarningIt is possible that lethal voltages wil
19、l bepresent when conducting test methods which evaluate electri-cal properties. It is essential that the test apparatus, and allassociated equipment electrically connected to it, be properlydesigned and installed for safe operation. Solidly ground allelectrically conductive parts that any person mig
20、ht come incontact with during the test. Provide means for use, at thecompletion of any test, to ground any parts which: were at highvoltage during the test; have the potential to acquire aninduced charge during the test; or have the potential to retaina charge even after disconnection of the voltage
21、 source.Thoroughly instruct all operators in the proper way to conducttests safely. When making high voltage tests, particularly incompressed gas or in oil, it is possible that the energy releasedat breakdown will be suffcient to result in fire, explosion, orrupture of the test chamber. Design test
22、equipment, testchambers, and test specimens so as to minimize the possibilityof such occurrences and to eliminate the possibility of personalinjury.SAMPLING4. Sample and Specimen Requirements4.1 The producer and consumer shall agree upon the num-ber of rolls selected. Unless otherwise specified a mi
23、nimum ofthree rolls per lot shall be selected.4.2 For sampling purposes, a lot consists of identifiablematerials of the same type, manufactured in one production runand offered for delivery at the same time.4.3 All test methods in this standard are intended to producea test value for a single roll.
24、Any reference to averaging ofmeasurements refers to the averaging of measurements on asingle roll and not to the average of all sample rolls.4.4 See Table 1 for a summary of standard requirements forthe number of test specimens to select from each sample roll,the number of test measurements to make
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD10002010STANDARDTESTMETHODSFORPRESSURESENSITIVEADHESIVECOATEDTAPESUSEDFORELECTRICALANDELECTRONICAPPLICATIONS

链接地址:http://www.mydoc123.com/p-509103.html