ASTM C923M-2007 Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures Pipes and Laterals (Metric)《在钢筋混凝土检修孔构造、管道和分支管道间的弹性连接件用标准规范(米制)》.pdf
《ASTM C923M-2007 Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures Pipes and Laterals (Metric)《在钢筋混凝土检修孔构造、管道和分支管道间的弹性连接件用标准规范(米制)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C923M-2007 Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures Pipes and Laterals (Metric)《在钢筋混凝土检修孔构造、管道和分支管道间的弹性连接件用标准规范(米制)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 923M 07METRICStandard Specification forResilient Connectors Between Reinforced Concrete ManholeStructures, Pipes, and Laterals Metric1This standard is issued under the fixed designation C 923M; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the minimum performance andmaterial requirements for
3、resilient connectors used for connec-tions between precast reinforced concrete manholes conform-ing to Specification C 478 and pipes, and between precastreinforced concrete pipe and laterals.1.1.1 These connectors are designed to minimize leakagebetween the pipe and manhole, and between the pipe and
4、lateral.1.2 This specification is the metric counterpart of Specifi-cation C 923.NOTE 1This specification covers the design, material, and perfor-mance of the resilient connection only. Connections covered by thisspecification are adequate for hydrostatic pressures up to 70 kPa (7.1 m)without leakag
5、e when tested in accordance with Section 7. Infiltration orexfiltration quantities for an installed system are dependent upon manyfactors other than the connections between manhole structures and pipe,and allowable quantities must be covered by other specifications andsuitable testing of the install
6、ed pipeline and system.1.3 The following precautionary caveat pertains only to thetest methods portion, Section 7, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to estab
7、lish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use. For a specific precaution statement, see7.2.5.2. Referenced Documents2.1 ASTM Standards:2A 493 Specification for Stainless Steel Wire and Wire Rodsfor Cold Heading and Cold ForgingA 6
8、66 Specification for Annealed or Cold-Worked Austen-itic Stainless Steel Sheet, Strip, Plate, and Flat BarC 478 Specification for Precast Reinforced Concrete Man-hole SectionsC 822 Terminology Relating to Concrete Pipe and RelatedProductsC 913 Specification for Precast Concrete Water and Waste-water
9、 StructuresD 395 Test Methods for Rubber PropertyCompressionSetD 412 Test Methods for Vulcanized Rubber and Thermo-plastic ElastomersTensionD 471 Test Method for Rubber PropertyEffect of LiquidsD 543 Practices for Evaluating the Resistance of Plastics toChemical ReagentsD 573 Test Method for RubberD
10、eterioration in an AirOvenD 624 Test Method for Tear Strength of ConventionalVulcanized Rubber and Thermoplastic ElastomersD 746 Test Method for Brittleness Temperature of Plasticsand Elastomers by ImpactD 883 Terminology Relating to PlasticsD 1171 Test Method for Rubber DeteriorationSurfaceOzone Cr
11、acking Outdoors or Chamber (Triangular Speci-mens)D 1566 Terminology Relating to RubberD 2240 Test Method for Rubber PropertyDurometerHardnessNOTE 2For more information about wastewater structures, see Speci-fication C 913.3. Terminology3.1 Definitions:3.1.1 Terms relating to plastics and rubber sha
12、ll be asdefined in Terminologies D 883 and D 1566, respectively.1This specification is under the jurisdiction of ASTM Committee C13 onConcrete Pipe and is the direct responsibility of Subcommittee C13.06 on Manholesand Specials.Current edition approved March 1, 2007. Published March 2007. Originally
13、approved in 1980. Last previous edition approved in 2002 as C 923M 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
14、 website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.2 Terms relating to precast concrete pipe, manholes, andrelated products shall be as defined in Terminology C 822 andas modified in 3.1.3-3.1.6.3.1.3 connectorthe entire as
15、sembly including resilientseals and metallic or nonmetallic mechanical devices, if any,used therein.3.1.4 lateralthe small diameter pipe connected to themain line.3.1.5 pipethe inlet or outlet pipe connected to the man-hole.3.1.6 pipe stuba capped or plugged pipe, or section ofpipe, installed in a m
16、anhole to allow for future connections.4. Materials and Manufacture4.1 All materials shall conform to the following require-ments:4.1.1 Resilient materials for connectors and filler rings shallbe manufactured from natural or synthetic rubber and shallconform to the requirements prescribed in Table 1
17、. If a spliceis used in the manufacture of the seal, its strength shall be suchthat the seal shall withstand a 180 bend with no visibleseparation.4.2 Mechanical DevicesExpansion rings, tension bands,and take-up devices used for mechanically compressing theresilient portion of the connector against t
18、he pipe or manholeshall be made from a material or materials in combination thatwill ensure durability, strength, resistance to corrosion, andhave properties that will ensure continued resistance to leak-age. All metallic mechanical devices and bolt assemblies usedto mechanically deform resilient ma
19、terials shall be constructedof corrosion resistant materials meeting the physical propertiesand chemical composition requirements of SpecificationsA 493 and A 666, Type 302 through Type 316.NOTE 3Experience has shown that successful performance of thisproduct depends on the type of bedding and backf
20、ill and the care in thefield installation of the manhole and connecting pipes. The owner iscautioned to require inspection at the construction site.5. Principles of Design5.1 The design of the connector shall be such that positiveseal is accomplished at two locations: (1) between the connec-tor and
21、the wall of the manhole or wastewater structure and (2)between the connector and the pipe. The seal between theconnector and the wall of the manhole or wastewater structureshall be made by either mechanical means, compression of theresilient material between the outside surface of the pipe andthe pi
22、pe opening in the wall of the manhole or wastewaterstructure, or by casting the connector integrally with the wall ofthe manhole or wastewater structure. The seal between theconnector and the pipe shall be made by mechanical means orby compression of the resilient material against the outside ofthe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC923M2007STANDARDSPECIFICATIONFORRESILIENTCONNECTORSBETWEENREINFORCEDCONCRETEMANHOLESTRUCTURESPIPESANDLATERALSMETRIC

链接地址:http://www.mydoc123.com/p-508818.html