《ASTM C923-2018 Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures Pipes and Laterals.pdf》由会员分享,可在线阅读,更多相关《ASTM C923-2018 Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures Pipes and Laterals.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C923 08 (Reapproved 2013)1C923 18Standard Specification forResilient Connectors Between Reinforced Concrete ManholeStructures, Pipes, and Laterals1This standard is issued under the fixed designation C923; the number immediately following the designation indicates the year oforiginal ado
2、ption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defen
3、se.1 NOTEEditorially corrected 5.3 in January 2016.1. Scope1.1 This specification covers the minimum performance and material requirements for resilient connectors used for connectionsbetween reinforced concrete manholes conforming to Specification C478 and pipes, between wastewater structures and p
4、ipes, andbetween precast reinforced concrete pipe and laterals.1.1.1 These connectors are designed to minimize leakage between the pipe and manhole, and between the pipe and lateral.1.2 A complete metric companion to Specification C923 has been developedC923M; therefore, no metric equivalents arepre
5、sented in this specification.NOTE 1This specification covers the design, material, and performance of the resilient connection only. Connections covered by this specificationare adequate for hydrostatic pressures up to 13 psi (30 ft) without leakage when tested in accordance with Section 7. Infiltra
6、tion or exfiltration quantitiesfor an installed system are dependent upon many factors other than the connections between manhole structures and pipe, and allowable quantities mustbe covered by other specifications and suitable testing of the installed pipeline and system.1.3 The following precautio
7、nary caveat pertains only to the test methods portion, Section 7, of this specification: This standarddoes not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety safety, health, and heal
8、thenvironmental practices and determine the applicability ofregulatory limitations prior to use. For a specific precaution statement, see 7.2.5.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Prin
9、ciples for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2A493 Specification for Stainless Steel Wire and Wire Rods for Cold Heading and Cold ForgingA6
10、66 Specification for Annealed or Cold-Worked Austenitic Stainless Steel Sheet, Strip, Plate, and Flat BarC478 Specification for Circular Precast Reinforced Concrete Manhole SectionsC822 Terminology Relating to Concrete Pipe and Related ProductsC913 Specification for Precast Concrete Water and Wastew
11、ater StructuresD395 Test Methods for Rubber PropertyCompression SetD412 Test Methods for Vulcanized Rubber and Thermoplastic ElastomersTensionD471 Test Method for Rubber PropertyEffect of LiquidsD543 Practices for Evaluating the Resistance of Plastics to Chemical ReagentsD573 Test Method for RubberD
12、eterioration in an Air OvenD624 Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic ElastomersD883 Terminology Relating to PlasticsD1149 Test Methods for Rubber DeteriorationCracking in an Ozone Controlled Environment1 This specification is under the jurisdiction ofASTM
13、 Committee C13 on Concrete Pipe and is the direct responsibility of Subcommittee C13.06 on Manholes and Specials.Current edition approved July 1, 2013Sept. 1, 2018. Published July 2013October 2018. Originally approved in 1979. Last previous edition approved in 20082013 asC923 08.C923 08(2013)1. DOI:
14、 10.1520/C0923-08R13E01.10.1520/C0923-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not
15、 an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate
16、. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1D1566 Terminology Relating to RubberD2137 Test Methods for Rubber Pr
17、opertyBrittleness Point of Flexible Polymers and Coated FabricsD2240 Test Method for Rubber PropertyDurometer HardnessNOTE 2For more information about wastewater structures, see Specification C913.3. Terminology3.1 Definitions:3.1.1 Terms relating to plastics and rubber shall be as defined in Termin
18、ologies D883 and D1566, respectively.3.1.2 Terms relating to precast concrete pipe, manholes, and related products shall be as defined in Terminology C822 and asmodified in 3.1.3 3.1.6.3.1.3 connectorthe entire assembly including resilient seals and metallic or nonmetallic mechanical devices, if any
19、, usedtherein.3.1.4 lateralthe small diameter pipe connected to the main line pipe.3.1.5 pipethe inlet or outlet pipe connected to the manhole.3.1.6 pipe stuba short section of pipe, installed in the structure as an inlet or outlet pipe, for future connection.4. Materials and Manufacture4.1 All mate
20、rials shall conform to the following requirements:4.1.1 Resilient materials for connectors and filler rings shall be manufactured from natural or synthetic rubber and shall conformto the requirements prescribed in Table 1. If a splice is used in the manufacture of the seal, its strength shall be suc
21、h that the sealshall withstand a 180 bend with no visible separation.4.2 Mechanical DevicesExpansion rings, tension bands, and take-up devices used for mechanically compressing the resilientportion of the connector against the pipe, manhole or wastewater structurestructure; shall be made from a mate
22、rial or materials incombination that will ensure durability, strength, resistance to corrosion, and have properties that will ensure continued resistanceto leakage.All metallic mechanical devices, including castings and bolt assemblies used to mechanically deform resilient materialsshall be construc
23、ted of corrosion resistant materials meeting the physical properties and chemical composition requirements ofSpecifications A493 and A666, Type 302 through Type 316.NOTE 3Experience has shown that successful performance of this product depends on the type of bedding and backfill and the care in the
24、fieldinstallation of the manhole or wastewater structure and connecting pipes. The owner is cautioned to require inspection at the construction site.5. Principles of Design5.1 The design of the connector shall be such that positive seal is accomplished at two locations: (1) between the connector and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC9232018STANDARDSPECIFICATIONFORRESILIENTCONNECTORSBETWEENREINFORCEDCONCRETEMANHOLESTRUCTURESPIPESANDLATERALSPDF

链接地址:http://www.mydoc123.com/p-508817.html