《ASTM C1374-2003 Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation《测定松散充填建筑物绝缘的安装厚度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1374-2003 Standard Test Method for Determination of Installed Thickness of Pneumatically Applied Loose-Fill Building Insulation《测定松散充填建筑物绝缘的安装厚度的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1374 03Standard Test Method forDetermination of Installed Thickness of PneumaticallyApplied Loose-Fill Building Insulation1This standard is issued under the fixed designation C 1374; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers determination of the installedthickness of pneumatically applied l
3、oose-fill building insula-tions prior to settling by simulating an open attic withhorizontal blown applications.1.2 This test method is a laboratory procedure for use bymanufacturers of loose-fill insulation for product design, labeldevelopment, and quality control testing. The apparatus usedproduce
4、s installed thickness results at a given mass/unit area.1.3 This test method is not the same as the design densityprocedures described in Test Methods C 520 or SpecificationsC 739 or C 764.1.4 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses ar
5、e providedfor information only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitatio
6、ns prior to use.2. Referenced Documents2.1 ASTM Standards:C 168 Terminology Relating to Thermal Insulation2C 520 Test Methods for Density of Granular Loose-FillInsulations2C 739 Specification for Cellulosic Fiber (Wood-Base)Loose-Fill Thermal Insulation2C 764 Specification for Mineral Fiber Loose-Fi
7、ll ThermalInsulation2E 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method33. Terminology3.1 DefinitionsUnless otherwise stated, the definitionslisted in Terminology C 168 are applicable herein.3.2 Definitions of Terms Specific to This Standard:3.2.1 insta
8、lled thickness, nthe average thickness, as mea-sured immediately after application of blown insulation mate-rial when applied at a given mass/unit area.4. Summary of Test Method4.1 A standardized test chamber of 80 ft2(7.4 m2) is used asa receptacle to receive a calculated mass/unit area of pneumati
9、-cally applied insulation.4.2 The mass of insulation to be blown into the test chamberis calculated from the bag label information.4.3 The mass of insulation prescribed in 4.2 is uniformlyblown into the test chamber.4.4 The thickness of the blown insulation is determined at13 predetermined locations
10、.4.5 The thickness average of three tests is the installedthickness for the mass/unit area being tested.5. Significance and Use5.1 This test method was designed to give the manufacturerof loose-fill insulation products a way of determining what theinitial installed thickness should be in a horizonta
11、l open atticfor pneumatic applications.5.2 The installed thickness value developed by this testmethod is intended to provide guidance to the installer in orderto achieve a minimum mass/unit area for a given R-value.5.3 For the purpose of product design, testing should bedone at a variety of R-values
12、. At least three R-values should beused: the lowest R-value on the product label, the highestR-value on the product label, and an R-value near the midpointof the R-value range.NOTE 1For quality control purposes, testing may be done at oneR-value of R-19 (h3ft23F/Btu) or higher.5.4 Specimens are blow
13、n in a manner consistent with theintended installation procedure. Blowing machine settingsshould be representative of those typically used for fieldapplication with that machine.5.5 The material blown for a given R-value as part of theinstalled thickness test equals the installed mass/unit area time
14、sthe test chamber area. This mass can be calculated frominformation provided on the package label at the R-valueprescribed.1This test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.32 on MechanicalProperties.Current edi
15、tion approved April 10, 2003. Published May 2003.Originallyapproved in 1997. Last previous edition approved in 1997 as C137497.2Annual Book of ASTM Standards, Vol 04.06.3Annual Book of ASTM Standards, Vol 14.02.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA
16、19428-2959, United States.6. Apparatus6.1 Blowing MachineA pneumatic blowing machine, de-signed primarily for handling loose-fill insulation materials,shall be used for blowing the insulation into the test chamber.This machine shall have throughput and material handlingcharacteristics similar to tha
17、t used in field applications.6.2 Blowing HoseThe machine should utilize 150 ft (46m) of 3in. (76mm) diameter flexible, corrugated blowinghose. At least 100 ft (30 m) of the hose should be elevatedbetween 10 and 20 ft (3 and 6 m) above the blowing machineto simulate a typical installation configurati
18、on. The hose shouldhave no more than eight 90 bends and no bends may be lessthan 4ft (1.2m) radius.NOTE 2It is good practice to clean the hose periodically by mechani-cally agitating it with the blower on. This practice should dislodge anypieces of insulation that might be caught in the hose.6.3 Tes
19、t Specimen ChamberThe specimen chamber shallbe constructed in accordance with Fig. 1 with the referencedowels positioned as shown in Fig. 2.NOTE 3For some insulation materials it may be necessary to use alarger test chamber than shown to accommodate a more representativesample, when the test chamber
20、 size is changed, the precision may change.6.4 Weighing DevicesA device is required to weigh thetest material before loading into hopper. This device mustdetermine the test material mass to within 0.5 %.6.5 Specimen Preparation RoomAn enclosed area wherethe test material is blown into the specimen c
21、hamber isrequired to protect the blowing operation from wind or strongair currents. Room geometry should not influence the blowingstream from the hose as long as there is adequate clearancearound the sides to maneuver.7. Sampling7.1 Follow sampling plans given in the material specifica-tions, regula
22、tions or other appropriate documents when appli-cable. In the absence of such directions, randomly select thenumber of bags of product required for testing to meetconditions in 8.2.7.2 Condition the sample material by exposure in a condi-tioned space as prescribed by the contract or regulatorydocume
23、nts. If conditioning is not required, material must be inequilibrium with the storage environment.8. Specimen Preparation8.1 Clean the specimen chamber to be free of dirt andinsulation prior to the start of the test.NOTE 4Many factors can influence the installation characteristics ofblown insulation
24、. These include blowing rate, machine adjustments, thesize and length of the hose, and the angle and dimensions of the hoseoutlet in relation to the test chamber. Where available, use manufacturersinstructions to establish machine settings.8.2 From product label information, calculate the mass ofins
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13742003STANDARDTESTMETHODFORDETERMINATIONOFINSTALLEDTHICKNESSOFPNEUMATICALLYAPPLIEDLOOSEFILLBUILDINGINSULATION

链接地址:http://www.mydoc123.com/p-464397.html