1、Designation: C 1148 92a (Reapproved 2008)Standard Test Method forMeasuring the Drying Shrinkage of Masonry Mortar1This standard is issued under the fixed designation C 1148; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of unre-strained drying shrinkage of masonry mortars.1.2 This test method i
3、s applicable to Specification C 270Type N, Type S, and Type M mortars under the property orproportion specifications. Due to the tendency to damage lowerstrength specimens during demolding, it is not applicable tolower strength mortars, such as Type O mortars.1.3 This test method is intended for res
4、earch purposes only.1.4 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.5 This standard does not purport to address all of thesafety
5、concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 109/C 109M Test Method for Compre
6、ssive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C 157/C 157M Test Method for Length Change of Hard-ened Hydraulic-Cement Mortar and ConcreteC 270 Specification for Mortar for Unit MasonryC 305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plast
7、ic ConsistencyC 490 Practice for Use of Apparatus for the Determinationof Length Change of Hardened Cement Paste, Mortar, andConcreteC511 Specification for Mixing Rooms, Moist Cabinets,Moist Rooms, and Water Storage Tanks Used in theTesting of Hydraulic Cements and ConcretesC 778 Specification for S
8、tandard Sand3. Significance and Use3.1 The drying shrinkage of mortar as determined by thistest method is a measure of the decrease in length of testspecimens under controlled drying conditions, after an initialperiod of moist curing.3.2 Since test specimens are not completely unrestrainedduring the
9、 initial period of moist curing, measurements ofdrying shrinkage by this test method are most useful forcomparative purposes rather than as absolute values.3.3 The drying shrinkage of unrestrained laboratory testedmortar samples is different from that experienced in a masonrywall where influences in
10、clude restraint, masonry unit absorp-tion, ambient temperature and humidity, thickness of joint,length of continuous wall, etc.4. Apparatus4.1 Scales and Weights, Glass Graduates, and Length Com-parator, conforming to requirements of Specification C 490.4.2 Molds (for test specimens), providing for
11、25 by 25 by285-mm (1 by 1 by 11.25-in.) prisms having an effective gagelength of 250 mm (10 in.), and conforming to the requirementsof Specification C 490.4.3 Studs, conforming to the requirements of SpecificationC 490.4.4 Tamper and Demolding Apparatus, conforming to re-quirements of Test Method C
12、157.4.5 Trowel, having a straight edged steel blade 100 to 150mm (4 to 6 in.) in length.5. Temperature and Humidity5.1 Molding RoomThe temperature of the molding room,dry materials, mixing water, and the relative humidity of the airin the molding room shall conform to the requirements ofSpecificatio
13、n C 490.5.2 Moist Storage FacilityThe temperature and humidityof the air in the moist storage facility shall conform to therequirements of Specification C511.1This test method is under the jurisdiction of ASTM Committee C12 on Mortarsand Grouts for Unit Masonry and is the direct responsibility of Su
14、bcommitteeC12.02 on Research and Methods of Test.Current edition approved Nov. 1, 2008. Published November 2008. Originallyapproved in 1990. Last previous edition approved in 2002 as C 1148 92a(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servic
15、e at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 Drying Room and ControlsThe drying room an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC11481992A2008STANDARDTESTMETHODFORMEASURINGTHEDRYINGSHRINKAGEOFMASONRYMORTAR 测量 砖石 建筑 灰浆 干缩性 标准

链接地址:http://www.mydoc123.com/p-463541.html