ASTM B496-2004(2010)e1 Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors《密实的圆形同心绞捻铜导线的标准规格》.pdf
《ASTM B496-2004(2010)e1 Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors《密实的圆形同心绞捻铜导线的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM B496-2004(2010)e1 Standard Specification for Compact Round Concentric-Lay-Stranded Copper Conductors《密实的圆形同心绞捻铜导线的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B496 04 (Reapproved 2010)1Standard Specification forCompact Round Concentric-Lay-Stranded CopperConductors1This standard is issued under the fixed designation B496; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEReferences to Sections 15 and 14 in 3.1.3 and 3.1.5, respectively, were corrected editorially in 2010.1. Scope1.1 This
3、 specification covers bare compact roundconcentric-lay-stranded conductors made from uncoated roundcopper wires for general use for electrical purposes. Theseconductors shall be constructed with a central core surroundedby one or more layers of helically laid compacted wires(Explanatory Note 1 and N
4、ote 2).1.2 The values stated in inch-pound or SI units are to beregarded separately as standard. The values in each system arenot exact equivalents; therefore, each system shall be usedindependently of the other. Combining values from the twosystems may result in nonconformance with the specificatio
5、n.1.2.1 For density, resistivity, and temperature, the valuesstated in SI units are to be regarded as standard.2. Referenced Documents2.1 The following documents of the issue in effect on dateof material purchase form a part of this specification to theextent referenced herein:2.2 ASTM Standards:2B3
6、 Specification for Soft or Annealed Copper WireB263 Test Method for Determination of Cross-SectionalArea of Stranded ConductorsB354 Terminology Relating to Uninsulated Metallic Elec-trical Conductors3. Ordering Information3.1 Orders for material under this specification shall includethe following in
7、formation:3.1.1 Quantity of each size (Table 1),3.1.2 Conductor size; circular-mil area or AWG, (Section 6and Table 1),3.1.3 Packaging (Section 15), if required,3.1.4 Special package marking, and3.1.5 Place of inspection (Section 14).4. Joints4.1 Welds and brazes may be made in rods or in wires prio
8、rto final drawing.4.2 Welds and brazes may be made in the individual rounddrawn wires for compact conductors, but shall not be closertogether than 1 ft (300 mm) for conductor of 19 wires or lessor closer than 1 ft (300 mm) in a layer for conductor of morethan 19 wires.4.3 No joint nor splice shall b
9、e made in a compact-strandedconductor as a whole.5. Lay5.1 The length of lay shall be not less than 8 nor more than16 times the outside diameter of the completed conductor.5.2 The direction of lay of the outer layer shall be left-hand,and it shall be reversed in successive layers, unidirectional, or
10、unilay.6. Construction6.1 The construction of the compact round concentric-lay-stranded conductors shall be as shown in Table 1.6.2 The starting round copper wires used in the fabricationof the compact round conductor shall be of such diameter as toproduce a finished conductor having a nominal cross
11、-sectionalarea and diameter as prescribed in Table 1.7. Density7.1 For the purpose of calculating linear densities, crosssections, and so forth, the density of the copper shall be takenas 8.89 g/cm3(0.32117 lb/in.3) at 20C.8. Mass and Resistance8.1 The mass per unit length and dc electrical resistan
12、ce ofa compact round conductor are greater than the total of thesecharacteristics of the compressed wires composing the finishedconductor, depending upon the lay. The standard increment ofmass per unit length and electrical resistance shall be taken as1This specification is under the jurisdiction of
13、 ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.04 onConductors of Copper and Copper Alloys.Current edition approved Oct. 1, 2010. Published December 2010. Originallyapproved in 1969. Last previous edition approved in 2004 as B496 04. DOI:10.1520/B049
14、6-04R10E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Dri
15、ve, PO Box C700, West Conshohocken, PA 19428-2959, United States.2 %. The nominal mass per unit length and dc resistance areshown in Table 1. When the dc resistance is measured at otherthan 20C, it shall be corrected by using the multiplying factorsgiven in Table 2.8.2 In cases where the lay is defi
16、nitely known, the incrementmay be calculated if desired (Explanatory Note 3).8.3 For conductors to be used in covered or insulated wiresor cables, direct current (DC) resistance measurement may beused instead of the method outlined in Section 9, to determinecompliance with this specification.9. Vari
17、ation in Area9.1 The cross-sectional area of the compact round conductorshall be not less than 98 % of the cross-sectional area asspecified in Column 1 of Table 1.9.2 The manufacturer shall determine the cross-sectionalarea by Test Method B263. In applying this method, theincrement in mass per unit
18、length resulting from stranding maybe the applicable value specified in 9.1 or may be calculatedfrom the measured dimensions of the sample under test. In caseof question regarding area compliance, the actual mass per unitlength increment due to stranding shall be calculated.10. Variation in Diameter
19、10.1 The average diameter of the compact-round conductorshall not vary by more than +1 % and 2 % from the diameterspecified in Table 1.11. Finish11.1 The conductor surface shall be smooth and free ofimperfections not consistent with the best commercial practice.12. Physical and Electrical Tests12.1
20、Tests for the physical and electrical properties of wirescomposing the conductors shall be made before stranding inaccordance with Specification B3 (Explanatory Note 4 andNote 5).13. Requirements for Wires13.1 Before stranding and compacting the copper wire shallmeet all of the requirements of Speci
21、fication B3.13.2 Wire shaped before stranding shall meet the require-ments of Specification B3, except for diameter tolerance. Theelongation requirement shall be the same as round wires ofequal nominal area. The area tolerance for shaped wires shallbe such that the finished conductor conforms to Sec
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB49620042010E1STANDARDSPECIFICATIONFORCOMPACTROUNDCONCENTRICLAYSTRANDEDCOPPERCONDUCTORS 密实 圆形 同心

链接地址:http://www.mydoc123.com/p-461390.html