ASTM B389-1981(2004) Standard Test Method for Thermal Deflection Rate of Spiral and Helical Coils of Thermostat Metal《恒温双金属螺旋形线圈的热偏转率的标准试验方法》.pdf
《ASTM B389-1981(2004) Standard Test Method for Thermal Deflection Rate of Spiral and Helical Coils of Thermostat Metal《恒温双金属螺旋形线圈的热偏转率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B389-1981(2004) Standard Test Method for Thermal Deflection Rate of Spiral and Helical Coils of Thermostat Metal《恒温双金属螺旋形线圈的热偏转率的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 389 81 (Reapproved 2004)Standard Test Method forThermal Deflection Rate of Spiral and Helical Coils ofThermostat Metal1This standard is issued under the fixed designation B 389; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the thermaldeflection rate of spiral and helical c
3、oils of thermostat metal.1.2 The values stated in inch-pound units are to be regardedas the standard. The metric equivalents of inch-pound unitsmay be approximate.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the
4、user of this standard to become familiarwith all hazards including those identified in the appropriateMaterial Safety Data Sheet for this product/material as pro-vided by the manufacturer, to establish appropriate safety andhealth practices, and determine the applicability of regulatorylimitations p
5、rior to use.2. Referenced Documents2.1 ASTM Standards:2E 77 Test Method for Inspection and Verification of Ther-mometers3. Terminology3.1 thermostat metala composite material, usually in theform of sheet or strip, comprising two or more materials of anyappropriate nature, metallic or otherwise, that
6、, by virtue ofdiffering expansivities of the components, tends to alter itscurvature when its temperature is changed.3.2 thermal deflection ratethe ratio of angular rotation totemperature change. It is a measure of the coils thermalactivity. It may have the units of angular degrees per degreeFahrenh
7、eit, or Celsius, and is expressed by the equation D=(A2A1)/(T2T1) where A2and A1are angular positions attemperature T2and T1respectively.3.3 spiral coila part made by winding strip on itself. Fig.1 and Fig. 2 show typical spiral coils, which can be wound withthe low-expansive side inside or outside,
8、 mounted on thespecimen holder.3.4 helical coila part made by winding strip in a formwherein the plane of the width of the strip is parallel to theaxial length. Fig. 3 shows a typical helical coil, which can bewound with the low-expansive side inside or outside, andright-hand or left-hand, mounted o
9、n the specimen holder.4. Summary of Test Method4.1 The test for thermal deflection rate of spiral and helicalcoils consists of measuring the angular rotation that a coilundergoes in response to a known temperature change.5. Significance and Use5.1 This test method simulates, to a practical degree, t
10、heoperation of the thermostat metal coil.5.2 The thermal deflection properties of a coil may varyfrom lot-to-lot of thermostat metal material. This method isuseful for determining the optimum thickness and length of thematerial for a given deflection specification.5.3 This method is useful as a qual
11、ity test to determineacceptance or rejection of a lot of thermostat metal coils.6. Apparatus6.1 Temperature BathA stirred liquid bath or uniformlyheated enclosure in which the specimen and mounting fixturecan be placed shall be used. An adjustable heating source isdesirable for maintaining the speci
12、men at the desired tempera-tures with a variation in temperature throughout the specimennot to exceed 0.5F (0.3C).6.2 ProtractorThe angular position at each test tempera-ture shall be measured by a protractor with a minimum divisionof 0.5.6.3 Temperature-Measuring ApparatusThe apparatus formaking te
13、mperature measurements shall be of such accuracythat the individual temperatures shall be known to be within60.5F (60.3C).6.4 Specimen HolderThe preferred methods of holdingspiral and helical coils are as follows:1This test method is under the jurisdiction of ASTM Committee B02 onNonferrous Metals a
14、nd Alloys and is the direct responsibility of SubcommitteeB02.10 on Thermostat Metals and Electrical Resistance Heating Materials.Current edition approved May 1, 2004. Published June 2004. Originallyapproved in 1962. Last previous edition approved in 1981 as B 389 81 (1998).2For referenced ASTM stan
15、dards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken,
16、PA 19428-2959, United States.6.4.1 Spiral CoilsThe specimen holder for spiral coilsshall provide means for securely holding the coil. Althoughother means of support are possible, the holder or mountingarbor shall be preferably circular cross section whose diametershall be as large as possible withou
17、t touching the inner turn ofthe coil under any conditions of test temperatures. The arborshall be slotted across its diameter and to a depth greater thanthe width of the specimen. The width of the slot shall beslightly narrower than the thickness of the specimen so that theinner tab will be a push o
18、r snug fit in the slot. The edges of theslot shall be sharp where it intersects the circumference of thearbor. The slot shall be so positioned in the arbor that the centerof rotation of the coil and the center of the arbor coincide.6.4.2 Helical CoilsThe specimen holder for helical coilsshall provid
19、e means for securely holding the coil. Althoughother means of support are possible, the coil shall be held withits axis in a vertical position, the bottom end of the coil securedand the top end allowed to rotate freely with a temperaturechange. Preferably the end of the coil with the center tab shal
20、lbe considered the bottom and secured by clamping or press-fitting the tab into a slotted arbor similar to that described in6.4.1 for spiral coils. The depth of the slot shall be such that thefull height of the tab shall be held. If the coils do not have acenter tab, the arbor shall contain provisio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB38919812004STANDARDTESTMETHODFORTHERMALDEFLECTIONRATEOFSPIRALANDHELICALCOILSOFTHERMOSTATMETAL 恒温

链接地址:http://www.mydoc123.com/p-461105.html