1、 ANSI/FCI 85-1-2011 AMERICAN NATIONAL STANDARDSTANDARD FOR PRODUCTION TESTING OF STEAM TRAPS Fluid Controls Institute, Inc. Sponsor: Fluid Controls Institute, Inc. 1300 Sumner Ave Cleveland, Ohio 44115-2851 ANSI/FCI 85-1-2011 AMERICAN NATIONAL STANDARD Standard for Production Testing of Steam Traps
2、Sponsor Fluid Controls Institute, Inc. iiAmericanNationalStandardAmerican National Standard implies a consensus of those substantially concerned with its scope and provisions. An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public. The exis
3、tence of an American National Standard does not in any respect preclude anyone, whether he has approved the standard or not, from manufacturing, marketing, purchasing or using products, processes, or procedures not conforming to the standard. American National Standards are subject to periodic revie
4、w and users are cautioned to obtain the latest editions. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard no later than five
5、 years from the date of publication. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Sponsored and published by: FLUID CONTROLS INSTITUTE, INC. 1300 Sumner Avenue Cleveland, OH 44115-2851 Phn:
6、 216/241-7333 Fax: 216/241-0105 E-Mail: fcifluidcontrolsinstitute.org URL: www.fluidcontrolsinstitute.org Copyright 2011 by Fluid Controls Institute, Inc. All Rights Reserved No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior
7、written permission of the publisher. Suggestions for improvement of this standard will be welcome. They should be sent to the Fluid Controls Institute, Inc. Printed in the United States of America iiiivCONTENTS PAGE Foreword iv 1. Scope . 1 2. Definitions 1 3. Technical Terms. 1-2 4. Production Test
8、s . 2 5. Operating Characteristics Test 2 6. Test Methods . 2-3 TABLE Table 1 . 3 vForeword (This foreword is included for information only and is not part of ANSI/FCI 85-1-2011, Standard for Production Testing of Steam Traps.) The following voluntary standard has been developed as a cooperative eff
9、ort by the Steam Trap Section of the Fluid Controls Institute, Inc. to assist manufacturers, users and specifiers of the products to comply with production and performance characteristics of automatic steam traps. FCI recognizes the need to periodically review and update this standard. Suggestions f
10、or improvement should be forwarded to the Fluid Controls Institute, Inc., 1300 Sumner Avenue, Cleveland, Ohio 44115-2851. All constructive suggestions for expansion and revision of this standard are welcome. In April 2003, the Steam Trap Section members agreed to revise the standard, in part to refl
11、ect a change in the ASME Code on hydrotest pressure. The existence of a Fluid Controls Institute (FCI) standard does not in any respect preclude any member or non-member from manufacturing or selling products not conforming to this standard nor is the FCI responsible for its use. 1ANSI/FCI 85-1-2011
12、 AMERICAN NATIONAL STANDARD STANDARD FOR PRODUCTION TESTING OF STEAM TRAPS 1. SCOPE 1.1 This standard specifies production and performance tests that are considered applicable to steam traps. 1.2 These tests may be conducted to ensure the correct functioning of a steam trap or to evaluate the perfor
13、mance of particular designs, either currently in production or under consideration for production. 2. DEFINITIONS 2.1 Steam trap - A self-contained valve which automatically drains the condensate from a steam containing enclosure while remaining tight to live steam, or, if necessary, allowing steam
14、to flow at a controlled or adjusted rate. Most steam traps will also pass non-condensable gases while remaining tight to live steam. 2.2 Production tests - Those tests carried out by the manufacturer to confirm that the steam trap functions correctly. These tests may be witnessed by the purchaser or
15、 his representative. In this case, these tests are referred to as acceptance tests. 2.3 Performance characteristic tests - Carried out to determine the operational characteristics of a particular design of steam trap. 3. TECHNICAL TERMS 3.1 Nominal Size (DN) - A numerical designation of size which i
16、s common to all components used in a piping system other than components designated by outside diameter. It is used for reference purposes and is normally only loosely related to manufacturing dimensions (inches). 3.2 Nominal Pressure (PN) - Internal pressure at a temperature of 68oF (20C) which is
17、used as a basis in the determination of limitations of the steam trap (lb/in2). 3.3 Maximum Allowable Pressure (PMA) - Maximum pressure that the shell of the steam trap can withstand permanently at a given temperature (lb/in2). 3.4 Maximum Operating Pressure (PMO) - Pressure for which a steam trap i
18、s rated by the manufacturer. This pressure is normally a function of the limitations related to the internal equipment of the steam trap (lb/in2). 3.5 Operating Pressure (PO) - Pressure measured at the inlet of the steam trap under operating conditions (lb/in2). 3.6 Operating Back Pressure (POB) - P
19、ressure measured at the outlet of the steam trap under operating conditions (lb/in2). 3.7 Maximum Operating Back Pressure (PMOB) -Maximum permissible pressure at the outlet of the steam trap allowing correct functioning (lb/in2). 3.8 Operating Differential Pressure (P) - Difference between the opera
20、ting pressure and the operating back pressure (lb/in2). 3.9 Maximum Differential Pressure (PMX) - Maximum difference between operating pressure and operating back pressure (lb/in2). 3.10 Minimum Differential Pressure (PMN) - Minimum difference between operating pressure and operating back pressure (
21、lb/in2). 3.11 Test Pressure (PT) - Pressure applied to the steam trap under test (lb/in2). 3.12 Maximum Test Pressure (PTMX) -Maximum test pressure of the steam trap including its internal mechanism (lb/in2). 3.13 Hydrostatic Proof Test Pressure (PTHP) - The hydrostatic proof test used in determinin
22、g PMA with consideration given to operating temperature (lb/in2). 3.14 Basic Temperature (TB) - Temperature taken into consideration in the determination of the limitations of the steam trap (oF). 3.15 Maximum Allowable Temperature (TMA) - Maximum temperature to which the shell of the steam trap can
23、 be raised permanently (oF). 3.16 Operating Temperature (TO) - Temperature measured at the inlet of the steam trap under operating conditions (oF). 3.17 Cold Condensate Capacity (QC) - Maximum mass of condensate that the steam trap can discharge in 1 hour at a given pressure and a temperature of 68o
24、F + 25oF (20oC + 14oC) the trap being fully open (lb/hr). 3.18 Hot Condensate Capacity (QH) - Maximum mass of condensate that a steam trap can discharge in 1 hour at a given pressure and temperature (lb/hr). 4. PRODUCTION TESTS 4.1 Product Inspection: Samples of the finished traps shall be visually
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIFCI8512011STANDARDFORPRODUCTIONTESTINGFORSTEAMTRAPS 疏水 产品 测试 标准 PDF

链接地址:http://www.mydoc123.com/p-434781.html