1、Chandrakant Patel, Ratnesh Sharma, Cullen Bash, Sven GraupnerHP Laboratories Palo Alto,Energy Aware Grid: Global Workload Placement based on Energy Efficiency,Grid Computing,New paradigm in distributed and pervasive computing for scientific as well as commercial applications.Based on coordinated res
2、ource sharing and problem solving in dynamic, multi institutional virtual organizations.,Energy Aware Grid,Objective: Build an energy aware grid. Problem: Thermal and energy management issues due to aggregation of computing, networking and storage hardware. Solution: Data center energy efficiency co
3、efficients: Workload placement decisions will be made across the Grid, based on these coefficients. Provide a global utility infrastructure explicitly incorporating energy efficiency and thermal management among data centers.,Cooling Issues,Example : A data center, with 1000 racks, approximately 25,
4、000 square feet. Requires 10 MW of power for the computing infrastructure.An additional 5 MW would be required to remove the dissipated heat. At $100/MWh, cooling would cost $4 million per annum.,Data Center thermo-mechanical architecture,Rows of racks with multiple air-cooled hardware.Presence of m
5、ultiple air-conditioning units.Higher airflow rates required due to “slim servers” and “blade servers”.,Problems in Data Center Cooling: Cooling at Chip Level 10% of total power Cooling at Data Center Level 50% of the total powerAdditional thermodynamic work for cooling. Non-uniform temperature and
6、airflow patterns. The data center has no well defined boundaries.No control mechanism to dissipate high heat loads.,Contributions of the paper,Propose an energy-aware co-allocator that redistributes computing within the global network of data centers. Examine the methods for evaluating energy effici
7、ency and thermal management parameters applicable to any data center cooling infrastructure.,Globus resource management architecture Ian Foster, Carl Kesselman :The Grid , Blueprint for a New Computing Infrastructure, 1999.,RSL (Resource Specification Language) Application specifies resource needs.B
8、roker Infrastructure Resolving higher-ordered RSL specifications into elementary, ground resource specifications.Ground RSL specification List of physical resources (machines, storage units, devices) needed to perform a computation.GRAMs (Globus Resource Allocation Managers) Allocates RSL ground res
9、ources from its resource pool for a scheduled time period. Assigns them to a specific computation.GIS information about resources and their availability.,Energy Aware Co-Allocator,Has information about a data center Resource Types machines, OS etc. Capacity of the resources. Schedules of allocations
10、 and reservations. The energy efficiency coefficient of the data center. Represents the energy cost when placing a workload in a particular data center.Data Center selection process Co-allocator will choose one or more GRAMs Necessary Conditions - Functional: Appropriate types of resources available
11、. Quantitative: Sufficient amounts of resources available. Schedule: Sufficient amounts of resource instances. Constraints: Restrictions, if provided by the application.,Energy Efficiency Coefficient ( ),A composite indicator of energy efficiency and thermal management of a data center.Factors which
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CHANDRAKANTPATEL RATNESHSHARMA CULLENBASH SVENPPT

链接地址:http://www.mydoc123.com/p-379473.html