FORD FLTM EU-BJ 003-02-2001 DETERMINATION OF LOW TEMPERATURE VISCOSITY BROOKFIELD VISCOSIMETER《低温粘度BROOKFIELD粘度计的测定》.pdf
《FORD FLTM EU-BJ 003-02-2001 DETERMINATION OF LOW TEMPERATURE VISCOSITY BROOKFIELD VISCOSIMETER《低温粘度BROOKFIELD粘度计的测定》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM EU-BJ 003-02-2001 DETERMINATION OF LOW TEMPERATURE VISCOSITY BROOKFIELD VISCOSIMETER《低温粘度BROOKFIELD粘度计的测定》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、FORD LABORATORY TEST METHOD EU-BJ 003-02 Date 2001 0723 1994 02 28 DETERMINATION OF LOW TEMPERATURE VISCOSITY BROOKFIELD VISCOSIMETER Action Revisions Revised Editorial - no technical change A. Cockman Application This method is used to determine the low temperature viscosities of new and used oils
2、by Brookfield viscosimeter. The method consists of cooling a test sample of oil in the cold bath and determining its viscosity without removing it from the cold bath. Apparatus and Materials Required Cold Box Capable of maintaining temperatures to - 40 OC within +/- 2 “C. Insulator Cork or wood to p
3、revent bath from resting on bottom of cold box. Stirring Rod Thermometer For viscosity bath (+ 20 to - 40 OC). Coolant Alcohol. Viscosity Bath 300 mm dia by 300 mm deep. Six Station Sample Indexing Cover Plates Plexiglass Cover With support for Brookfield viscosimeter. This item replaces one of the
4、two pyrofoam covers of the freezer. Support Stand For stirrer motor. Thermocouple (Iron-constantan) immersed in test fluid sample. Copyright 02001, Ford Global Technologies, Inc FORD LABORATORY TEST METHOD EU-BJ 003-02 Brookfield Viscosimeter Model No. LVF or LVT, and spindles No. 3 and No. 4 with g
5、uard. Six Stainless Steel Sample Beakers (500 mL) Mixer Pyrometer Potentiometer With an accuracy of 1 % Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 OC and 50 +/- 5 % relative humidity for not less than 24
6、h prior to testing and tested under the same conditions unless otherwise specified. Procedure 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 o. Fill beakers with 275 +/- 5 mL of oil under test. Heat oil in oven at 100 OC for 30 minutes to remove any moisture present in test sample. Cool to 23 +/- 2 OC. Place Pyrex gl
7、ass bath into cold cabinet on insulator spacer. Adjust the height so the top of the bath is 65 mm below the top of the cold cabinet. Fill the bath with alcohol, acetone, or any other low freezing point liquid. Place indexing cover on bath and insert test beakers. Adjust cold box to desired temperatu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMEUBJ003022001DETERMINATIONOFLOWTEMPERATUREVISCOSITYBROOKFIELDVISCOSIMETER 低温 粘度 BROOKFIELD 粘度计

链接地址:http://www.mydoc123.com/p-747807.html