《EN 50131-2-7-1-2012 en Alarm systems - Intrusion and hold-up systems - Part 2-7-1 Intrusion detectors - Glass break detectors (acoustic) (Incorporates Amendment A2 2016).pdf》由会员分享,可在线阅读,更多相关《EN 50131-2-7-1-2012 en Alarm systems - Intrusion and hold-up systems - Part 2-7-1 Intrusion detectors - Glass break detectors (acoustic) (Incorporates Amendment A2 2016).pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationAlarm systems Intrusion and hold-up systemsPart 2-7-1: Intrusion detectors Glass break detectors (acoustic)BS EN 50131-2-7-1:2012BS EN 50131-2-7-1:2012+A1:2013Incorporating corrigendum August 2014BS EN 50131-2-7-1:2012+A1:2013 BRITISH STANDARDNational forewordThis British St
2、andard is the UK implementation of EN 50131-2-7-1:2012+A1:2013. It supersedes BS EN 50131-2-7-1:2012, which is withdrawn.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to CENELEC text carry the number of the CENELEC amendment
3、. For example, text altered by CENELEC amendment A1 is indicated by .The UK participation in its preparation was entrusted by Technical Committee GW/1, Electronic security systems, to Subcommittee GW/1/1, Alarm components.A list of organizations represented on this subcommittee can be obtained on re
4、quest to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2014. Published by BSI Standards Limited 2014ISBN 978 0 580 83561 2ICS 13.320Compliance with a British
5、Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 October 2013.Amendments/corrigenda issued since publicationDate Text affected31 August 2014 Implementation of CENELEC Interpretation She
6、et February 2014 in National Annex NA31 August 2014 Implementation of CENELEC amendment A1:2013EN 50131-2-7-1:2012/IS1:2014 (E) 4 Text of IS1 to EN 50131-2-7-1:2012 Clause: Annex D and Figure D.1 Question: Would it be allowed for test purposes (for test houses and manufacturers) to use the NeoDym ma
7、gnet listed below instead of the AlNiCo version described in Annex D and Figure D.1 for reproducible tests ? Interpretation: Yes, because this will allow stable and reproducible test results, which is not guaranteed while using the AlNiCo magnet due to the nature of the magnet material. Furthermore,
8、 the test magnet described below allows a high-level degree of backward compatibility for already tested products, while it gives the stability required. Therefore, when the NeoDym magnet is used for test purposes (for test houses and manufacturers), the text below may be used in place of Annex D. V
9、alidity: This interpretation remains valid until an amendment or updated standard dealing with this issue is published by CENELEC. BS EN 50131-2-7-1:2012+A1:2013National Annex NA (Informative)EN 50131-2-7-1:2012/IS1:2014 (E) 5 Annex D (normative) Dimensions it is not required to operate when the I i
10、f this is the case, this requirement applies.- 13 - EN 50131-2-7-1:2012 4.7.2 Immunity to environmental conditions All detectors shall meet the requirements of the relevant environmental class and equipment class as specified by the manufacturer of the environmental tests described in Table 7 and Ta
11、ble 8. These tests shall be performed in accordance with EN 50130-5 and EN 50130-4. Impact tests shall not be carried out on delicate detector components such as LEDs or microphones. Unless specified otherwise for operational tests, the detector shall not generate unintentional intrusion, tamper, fa
12、ult or other signals or messages when subjected to the specified range of environmental conditions. For endurance tests, the detector shall continue to meet the requirements of this standard after being subjected to the specified range of environmental conditions. 5 Marking, identification and docum
13、entation 5.1 Marking and/or identification Marking and/or identification shall be applied to the product in accordance with the requirements of EN 50131-1. 5.2 Documentation The product shall be accompanied with clear and concise documentation conforming to the main systems document EN 50131-1. The
14、documentation shall additionally state: a) A list of all options, functions, inputs, signals or messages, indications and their relevant characteristics; b) Any disallowed field adjustable control settings or combinations of these; c) Where alignment adjustments are provided, these shall be labelled
15、 as to their function; d) The manufacturers quoted nominal operating voltage and the maximum and quiescent current consumption at that voltage; e) The detection range (minimum and maximum) and coverage diagram showing top and side elevations. The installation instructions shall be clear and concise
16、that the maximum range will include the farthest point from the sensor input to any point of the monitored glass; f) All types, minimum size, minimum and maximum thickness of glass for which the detector is claimed to detect; g) Any restrictions according to the mounting location of the detector, or
17、 any other restrictions which apply to the performance of the detector; h) A warning to the user not to obscure partially or completely the detectors field of view with large objects such as furniture, curtains, blinds, if required, i) any specific settings needed to meet the requirements of this do
18、cument at the claimed grade. 6 Testing 6.1 General The tests are intended to be primarily concerned with verifying the correct operation of the detector to the specification provided by the manufacturer. All the test parameters specified shall carry a general tolerance of 10 % unless otherwise state
19、d, for acoustic measurements a general tolerance of 3 dB is applicable. A list of tests appears as a general test matrix in Annex H. BS EN 50131-2-7-1:2012BS EN 50131-2-7-1:2012+A1:2013EN 50131-2-7-1:2012+A1:2013All detectors shall meet the requirements of the relevant environmental class and equipm
20、ent class as specified by the manufacturer of the environmental tests described in Table 8 and Table 9. These tests shall be performed in accordance with EN 50130-5 and EN 50130-4.EN 50131-2-7-1:2012 - 14 - 6.2 General test conditions 6.2.1 Standard laboratory conditions for testing The general atmo
21、spheric conditions in the measurement and tests laboratory shall be those specified in EN 60068-1:1994, 5.3.1, unless stated otherwise. Temperature 15 C to 35 C Relative humidity 25 % RH to 75 % RH Air pressure 86 kPa to 106 kPa Noise level Shall not exceed 65 dB C-weighted (alternatively 70 dB line
22、ar) in the frequency range of 12,5 kHz to 16 kHz; time averaging has to be set to fast (0,125 s) when measuring 6.2.2 General detection testing environment and procedures 6.2.2.1 General Manufacturers documented instructions regarding mounting and operation shall be read and applied to all tests. 6.
23、2.2.2 Testing environment For passive acoustic glass break detectors, the detection tests require an enclosed, unobstructed and draught-free area having a length at least 25 % larger in the long dimension and at least half of long dimension length in the short dimension than the manufacturers claime
24、d range. See Annex A for a description of a potential test room. The minimum sized standardized glass types (glass window or door glass pane as defined in Annex B) needs to be in a fixed off centre position in both directions (horizontal and vertical) in a fixed solid wall e.g. brick, block or concr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN501312712012ENALARMSYSTEMSINTRUSIONANDHOLDUPSYSTEMSPART271INTRUSIONDETECTORSGLASSBREAKDETECTORSACOUSTICINCORPORATESAMENDMENTA22016PDF

链接地址:http://www.mydoc123.com/p-716718.html