BS EN ISO 14971-2012 Medical devices Application of risk management to medical devices《医疗器械 医疗器械风险管理的应用》.pdf
《BS EN ISO 14971-2012 Medical devices Application of risk management to medical devices《医疗器械 医疗器械风险管理的应用》.pdf》由会员分享,可在线阅读,更多相关《BS EN ISO 14971-2012 Medical devices Application of risk management to medical devices《医疗器械 医疗器械风险管理的应用》.pdf(106页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN ISO 14971:2012Medical devices Applicationof risk management to medicaldevices (ISO 14971:2007,Corrected version 2007-10-01)BS EN ISO 14971:2012 BRITISH STANDARDNational for
2、ewordThis British Standard is the UK implementation of EN ISO 14971:2012. It is identical to ISO 14971:2007. It supersedes BS EN ISO 14971:2009 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee CH/210/4, Risk analysis for Medical Devices.A list of organi
3、zations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2012. Published by BSI Standards Limited 201
4、2ISBN 978 0 580 79952 5ICS 11.040.01 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 July 2012.Amendments issued since publicationDate Text affectedEUROPEAN S
5、TANDARD NORME EUROPENNE EUROPISCHE NORM EN ISO 14971 July 2012 ICS 11.040.01 Supersedes EN ISO 14971:2009 English version Medical devices - Application of risk management to medical devices (ISO 14971:2007, Corrected version 2007-10-01) Dispositifs mdicaux - Application de la gestion des risques aux
6、 dispositifs mdicaux (ISO 14971:2007, Version corrige de 2007-10-01) Medizinprodukte - Anwendung des Risikomanagements auf Medizinprodukte (ISO 14971:2007, korrigierte Fassung 2007-10-01) This European Standard was approved by CEN on 16 May 2012. CEN and CENELEC members are bound to comply with the
7、CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management
8、Centre or to any CEN and CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN and CENELEC member into its own language and notified to the CEN-CENELEC Management Centr
9、e has the same status as the official versions. CEN and CENELEC members are the national standards bodies and national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece
10、, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN/CENELEC Ref. No. EN ISO 14971
11、:2012 E4 Annex ZA (informative) Relationship between this European Standard and Requirements of EU Directive 93/42/EEC on Medical Devices This European Standard has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association to provide a means of con
12、forming to Requirements of the New Approach Directive 93/42/EEC on Medical Devices. Within the limits of the scope of this standard (Clause 1 of EN ISO 14971:2012), compliance with the clauses of this standard confers a presumption of conformity with requirements of that Directive and associated EFT
13、A regulations, once this standard is cited in the Official Journal of the European Union under that Directive and has been implemented as a national standard in at least one Member State. This Annex ZA explains to which requirements, under which conditions and to what extent presumption of conformit
14、y can be claimed. Whilst only a limited number of requirements is covered just by the application of this standard, authorities in charge of medical devices strongly recommend using this standard. The standard leads, according to experience of the authorities, to a higher degree of compliance with l
15、egal obligations. EN ISO 14971:2012 provides a process for managing risks associated with medical devices. Because this standard describes an ongoing, lifecycle process applicable in part or in all to the Essential Requirements of Directive 93/42/EEC on Medical Devices, it is very exceptionally not
16、meaningful to link individual clauses of the standard to specific corresponding Essential Requirements. Compliance with all the normative clauses in EN ISO 14971 will ensure that a process is in place to address general risk management aspects related to medical devices, which are included in the Es
17、sential Requirements. However, because this is an international standard, intended to be applicable in jurisdictions all over the world, it is not the primary goal of the standard to cover exactly any of the European Essential Requirements. Therefore, for all of the Essential Requirements, conformit
18、y is not entirely achieved by complying only with the requirements specified in this standard. Manufacturers and conformity assessment bodies will need to feed the Essential Requirements into the risk management process provided by the standard. Explanation on the correspondence of the standard and
19、the Essential Requirements is included in Table ZA.1. Further explanation on content deviations between the standard and the ERs is provided below the table. BS EN ISO 14971:2012 EN ISO 14971:2012 (E) 5g3Table ZA.1 Correspondence between this European Standard and Directive 93/42/EEC Clause(s)/subcl
20、ause(s) of this EN Essential Requirements (ERs) of Directive 93/42/EEC Qualifying remarks/Notes 1-9 1 ER 1 is not directly covered by EN ISO 14971, since the standard does not provide requirements on design and manufacture. However, the standard provides a tool to generate the information that is a
21、necessary preliminary step for a manufacturer to demonstrate that the device is in conformity with ER 1. For content deviations, see points 1, 2, 3, 4 below. 1-9 2 - The second sentence of ER 2 is partly covered by 6.2. For content deviations, see points 1, 2, 3, 5, 6, 7 below. - The other parts of
22、ER 2 are not directly covered by EN ISO 14971, since the standard does not provide requirements on design and construction, nor does it apply the concept of safety principles as intended in the MDD. However, the standard provides a tool to generate the information that is a necessary preliminary ste
23、p for a manufacturer to demonstrate that the device is in conformity with ER 2. 1-9 4 ER 4 is not directly covered by EN ISO 14971, since the standard does not apply the concept of safety principles as intended in the MDD. However, the standard provides a tool to generate the information that is a n
24、ecessary preliminary step for a manufacturer to demonstrate that the device is in conformity with ER 4. 1-9 5 ER 5 is not directly covered by EN ISO 14971, since the standard does not provide requirements on design, manufacture or packaging. However, the standard provides a tool to generate the info
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSENISO149712012MEDICALDEVICESAPPLICATIONOFRISKMANAGEMENTTOMEDICALDEVICES 医疗器械 风险 管理 应用 PDF

链接地址:http://www.mydoc123.com/p-580818.html