1、Designation: E934 94 (Reapproved 2015)Standard Specification forSerological Pipet, Disposable Plastic1This standard is issued under the fixed designation E934; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers disposable plasti
3、c serologicalpipets, calibrated “to deliver” when measuring volumes ofliquids.1.1.1 Any institution or individual who reuses a disposablepipet must bear full responsibility for its safety and effective-ness.2. Referenced Documents2.1 ASTM Standards:2D703 Specification for Polystyrene Molding and Ext
4、rusionMaterials (Withdrawn 0)3E542 Practice for Calibration of Laboratory VolumetricApparatusE920 Specification for Commercially Packaged LaboratoryApparatusE921 Specification for Export Packaged Laboratory Appa-ratusE1133 Practice for Performance Testing of Packaged Labo-ratory Apparatus for United
5、 States Government Procure-ments3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 accuracythe expected distribution of mean volumesaround the stated volume.3.1.2 coeffcient of variationthe expected distribution ofindividual volumes around the mean volume.3.1.3 disposable pipetsu
6、ch pipets will only be expected toprovide their specified performance during their original use oroperation.4. Material and Manufacturer4.1 The pipets made to this specification shall be fabricatedfrom crystal grade, uncolored polystyrene, or regrind of same,in accordance with Specification D703.5.
7、Design5.1 Shape0.5, 1.0, and 2.0-cm3pipets shall be straight andof one-piece construction.Any cross section of a pipet taken ina plane perpendicular to the longitudinal axis shall be circular.5.1.1 Pipets of 5.0, 10.0, 25.0, and 50.0 cm3shall be straightand may consist of one, two, or three componen
8、ts, the extrudedpipet barrel, the pulled or injection molded tip, and the plain,pulled, or injection molded top end. Any cross section of apipet taken in a plane perpendicular to the longitudinal axisshall be circular.5.2 Delivery TipsDelivery tips shall be made with agradual taper of 10 to 40 mm. T
9、he tip end shall be reasonablyperpendicular to the longitudinal axis of the pipet, and shall befree of internal flash.5.3 Top EndThe 5, 10, 25.0, and 50.0-cm3sizes shall havea top end with an inside diameter of 2 to 6.5 mm for aminimum distance of 20 mm from the open end, and shall havean overall le
10、ngth of 24 to 28 mm. On all sizes, the top end shallbe suitable for plugging with filtering material. The top may beflat or chamfered and must be without sharp outer edges. Alltop ends shall be reasonably perpendicular to the longitudinalaxis of the pipet. The O.D. of top end should range from 7 to9
11、 mm.5.4 Dimensions and Outflow TimesThe limiting dimen-sions and outflow times shall be as shown in Table 1. Outflowtimes shall be determined by means of a stopwatch onunplugged pipets when using distilled water at 25 6 5C.6. Markings6.1 Graduation MarkingsGraduation lines shall be be-tween 0.2 mm a
12、nd 0.5 mm in width, and in a plane perpen-dicular to the longitudinal axis of the pipet parallel to eachother.Amain graduation line shall extend at least35 of the wayaround the pipet. The values of all main graduation lines shallbe in Arabic numbers directly above the lines referenced.Intermediate g
13、raduation lines shall extend at least15 of the way1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onLaboratory Ware and Supplies.Current edition approved June 1, 2015. Published July 2015. Originally a
14、pprovedin 1983. Last previous edition approved in 2009 as E934 94 (2009). DOI:10.1520/E0934-94R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docu
15、ment Summary page onthe ASTM website.3The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1around the pipet, and least graduation lines shall extend at leas
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME934199420151897STANDARDSPECIFICATIONFORSEROLOGICALPIPETDISPOSABLEPLASTIC 一次性 塑料 血清 移液管 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-533802.html