《ASTM E2821-2013 Standard Specification for &65279 Compacted Mineral-Insulated Metal-Sheathed Cable Used in Industrial Resistance Thermometers《工业电阻温度计用压实矿物绝缘 金属护套电缆的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2821-2013 Standard Specification for &65279 Compacted Mineral-Insulated Metal-Sheathed Cable Used in Industrial Resistance Thermometers《工业电阻温度计用压实矿物绝缘 金属护套电缆的标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2821 13Standard Specification forCompacted Mineral-Insulated, Metal-Sheathed Cable Usedin Industrial Resistance Thermometers1This standard is issued under the fixed designation E2821; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the requirements forcompacted, mineral-insulated, metal-sheathed
3、(MIMS) cablesused to manufacture metal-sheathed, industrial resistance ther-mometers referred to in this document as Resistance Tempera-ture Detectors or RTDs.1.2 The materials of construction include copper, nickel-clad copper, copper-45 % nickel (constantan), or nickelconductors, an austenitic sta
4、inless steel or nickel-chromiumalloy sheath, and either magnesia (MgO) or alumina (Al2O3)insulation.1.3 The cable diameter is between 0.093 and 0.500 in. (2.33and 12.70 mm) and contains between two and eightconductors, set in various design configurations and wirespacings.1.4 The values of temperatu
5、re in this specification are basedon the International Temperature Scale of 1990 (ITS-90).1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered stan
6、dard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referen
7、ced Documents2.1 The latest issues of the following documents form a partof this specification to the extent specified herein. In the eventof a conflict between this specification and other specificationsreferenced herein, this specification shall take precedence.2.2 Due to the similarity between Co
8、mpacted MIMS Ther-mocouple Cable and Compacted MIMS Cable, some Thermo-couple ASTM Standards may apply.2.3 ASTM Standards:2A213/A213M Specification for Seamless Ferritic and Aus-tenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger TubesA249/A249M Specification for Welded Austenitic SteelBoile
9、r, Superheater, Heat-Exchanger, and CondenserTubesA269 Specification for Seamless and Welded AusteniticStainless Steel Tubing for General ServiceA632 Specification for Seamless and Welded AusteniticStainless Steel Tubing (Small-Diameter) for General Ser-viceB163 Specification for Seamless Nickel and
10、 Nickel AlloyCondenser and Heat-Exchanger TubesB167 Specification for Nickel-Chromium-Iron Alloys (UNSN06600, N06601, N06603, N06690, N06693, N06025,N06045, and N06696), Nickel-Chromium-Cobalt-Molybdenum Alloy (UNS N06617), and Nickel-Iron-Chromium-Tungsten Alloy (UNS N06674) Seamless Pipeand TubeB5
11、16 Specification forWelded Nickel-Chromium-IronAlloy(UNS N06600, UNS N06603, UNS N06025, and UNSN06045) TubesE344 Terminology Relating to Thermometry and Hydrom-etryE780 Test Method for Measuring the Insulation Resistanceof Mineral-Insulated, Metal-Sheathed Thermocouples andThermocouple Cable at Roo
12、m TemperatureE839 Test Methods for Sheathed Thermocouples andSheathed Thermocouple CableE1137/E1137M Specification for Industrial Platinum Resis-tance ThermometersE1652 Specification for Magnesium Oxide and AluminumOxide Powder and Crushable Insulators Used in theManufacture of Metal-Sheathed Platin
13、um ResistanceThermometers, Base Metal Thermocouples, and NobleMetal Thermocouples1This specification is under the jurisdiction of ASTM Committee E20 onTemperature Measurement and is the direct responsibility of Subcommittee E20.03on Resistance Thermometers.Current edition approved May 1, 2013. Publi
14、shed July 2013. DOI: 10.1520/E2821-132For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM Internati
15、onal, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.4 ANSI Standard:3ANSI B46.1 Surface Texture, Surface Roughness, Wavinessand Lay3. Terminology3.1 DefinitionsThe definitions given in Terminology E344shall apply to this specification.3.2 Definitions:3.2.1 lot
16、, na quantity of finished MIMS RTD cablemanufactured from tubing from the same heat, wire from thesame spool and heat, and insulation from the same batch, thenassembled and processed together under controlled productionconditions to the required final outside diameter.3.2.2 raw material, ntubing, in
17、sulation, and wires used infabrication of MIMS RTD cable.4. Significance and Use4.1 MIMS RTD cable may be used as follows:4.1.1 As a cable for attaching the sensing element to asensor termination within a thermometer (see SpecificationE1137/E1137M).4.1.2 As an extension cable connecting a thermomete
18、r toanother device.5. Ordering Information and Basis for Purchase5.1 The purchasing documents shall specify the followingoptions:5.1.1 The total length of finished MIMS RTD cable or thelength of each piece of finished MIMS RTD cable.5.1.2 The material and number of conductors (see Fig. 1)and the all
19、owable variation in conductor resistances if otherthan that specified in 6.2. Consult individual manufacturers forthe number of conductors which are limited by cable size.5.1.3 The sheath material (see 7.3) and whether it shall beseamless or welded and drawn. Note that other sheath materialmay be us
20、ed with purchaser and producer agreement.5.1.4 The nominal outside diameter of the sheath (see 6.3).5.1.5 The insulating material (either MgO or Al2O3) and itsrespective type (see 7.2). Note that other insulation composi-tion and impurity levels may be used with purchaser andproducer agreement.5.1.6
21、 The seal to be applied to the exposed insulation at thecable end(s) prior to shipment (see 11.1).5.1.7 Supplementary testing or material requirements (seeSupplementary Requirements).5.1.8 Any deviations from this specification or the refer-enced documents.5.1.9 The Optional Clearance if applicable
22、(see Fig. 1).6. General Requirements6.1 MIMS RTD CableCable shall be in accordance withthis specification (see Fig. 2). Fig. 2 shows a cable with twoconductors, but more than two conductors may be specified.6.2 Conductor Resistance MatchThe resistance of eachconductor shall be measured. The differen
23、ce between themaximum conductor resistance and minimum conductor resis-tance shall not exceed 10 % of the minimum conductorresistance.6.3 DimensionsThe dimensional and tolerance require-ments for sheath diameter and wall thickness, conductordiameter, and insulation thickness depicted in Fig. 2 andsu
24、mmarized in Table 1 shall be based on the nominal sheathoutside diameters. The purchaser need only specify the cablesoutside diameter and number of conductors required in theordering documents. The preferred cable sizes are listed inTable 2. For any nominal sheath size:6.3.1 The outside diameter tol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME28212013STANDARDSPECIFICATIONFOR65279COMPACTEDMINERALINSULATEDMETALSHEATHEDCABLEUSEDININDUSTRIALRESISTANCETHERMOMETERS

链接地址:http://www.mydoc123.com/p-531950.html