ASTM E1969-2006 Standard Guide for Microcrystal Testing in the Forensic Analysis of Methamphetamine and Amphetamine《甲基苯异丙胺法医检定法中微晶体试验的标准指南》.pdf
《ASTM E1969-2006 Standard Guide for Microcrystal Testing in the Forensic Analysis of Methamphetamine and Amphetamine《甲基苯异丙胺法医检定法中微晶体试验的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1969-2006 Standard Guide for Microcrystal Testing in the Forensic Analysis of Methamphetamine and Amphetamine《甲基苯异丙胺法医检定法中微晶体试验的标准指南》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1969 06Standard Guide forMicrocrystal Testing in the Forensic Analysis ofMethamphetamine and Amphetamine1This standard is issued under the fixed designation E 1969; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONMicrocrystal tests are primarily chemical-precipitation tests in which a light microscope is used toobserve
3、and distinguish the different types of crystals formed. These tests require skill and expertiseon the part of the analyst that can be gained adequately only through appropriate training andexperience in their use. These tests should not be attempted by those who are unfamiliar with themfor use in th
4、e analysis of methamphetamine or amphetamine.1. Scope1.1 This guide describes some standard procedures appli-cable to the analysis of methamphetamine and amphetamineusing microcrystal tests.1.2 These procedures are applicable to methamphetamineand amphetamine, which are present in solid dosage form
5、or aninjectable liquid form. These procedures are not typicallyapplicable to the analysis of methamphetamine and amphet-amine in biological samples.1.3 This guide offers an organized collection of informationor a series of options and does not recommend a specificcourse of action. This document cann
6、ot replace education orexperience and should be used in conjunction with professionaljudgment. Not all aspects of this guide may be applicable in allcircumstances. This ASTM standard is not intended to repre-sent or replace the standard of care by which the adequacy ofa given professional service mu
7、st be judged, nor should thisdocument be applied without consideration of a projects manyunique aspects. The word “Standard” in the title of thisdocument means only that the document has been approvedthrough the ASTM consensus process.1.4 This standard does not purport to address all of thesafety co
8、ncerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions of Terms Specific to This Standard:2.1.1 aggregati
9、on, nthe collecting of units or parts into amass or whole.2.1.2 birefringence, nproperty of some crystals, havingmore than one refraction index. This property will result ininterference colors, which are viewed through a polarized lightmicroscope.2.1.3 blades, nbroad, flat, elongated crystals.2.1.4
10、grains, nthick tablets having nearly equal width,breadth and thickness.2.1.5 habit, nthe external morphology of the crystal.2.1.6 microdrop, na small drop of liquid that would fit onthe end of a standard size, flattened toothpick. The approximatevolume of this drop would be 10 to 25 L.2.1.7 needles
11、(acicular), nlong, thin crystals with pointedends.2.1.8 plates, nblades with nearly equal length and breadthand of a thickness substantially less than the width.2.1.9 rods, nlong, thin crystals with squared off ends.2.1.10 tablets, nplates with appreciable thickness but lessthan the length or breadt
12、h.3. Summary of the Technique3.1 A small sample of the material containing the suspectedmethamphetamine or amphetamine is dissolved in an appro-priate acid and the appropriate precipitating reagent is added.1This guide is under the jurisdiction of ASTM Committee E30 on ForensicSciences and is the di
13、rect responsibility on Subcommittee E30.01 on Criminalistics.Current edition approved Aug. 1, 2006. Published September 2006. Originallyapproved in 1998. Last previous edition approved in 2001 as E 196901.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-
14、2959, United States.The crystals that are formed are observed and distinguishedutilizing a light microscope.3.2 If the proper formation of crystals is inhibited by thepresence of diluents, a purification of the sample based on thevolatility of methamphetamine and amphetamine may beperformed.4. Signi
15、ficance and Use4.1 This technique produces a chemical-precipitation reac-tion between methamphetamine or amphetamine and the pre-cipitating reagent. The habit and the aggregation of the crystalsformed may be used to distinguish methamphetamine andamphetamine from other drugs.5. Interferences5.1 Dilu
16、ents/AdulterantsDiluents/adulterants present incombination with methamphetamine or amphetamine in thesample to be tested may inhibit crystal formation or result incrystals that are distorted or otherwise rendered unidentifiable.In these instances, it will be necessary to separate the meth-amphetamin
17、e or amphetamine from the diluents or to use othertesting methods to analyze the methamphetamine or amphet-amine.6. Apparatus6.1 A standard light microscope capable of varying magni-fications including 1003 is needed for viewing the crystals. Apolarized light attachment is not essential, but is desi
18、rable,because the heavy metal crystals of methamphetamine andamphetamine are birefringent.7. Reagents and Materials7.1 10 % Solution of Hydrochloric Acid.7.2 Concentrated Phosphoric Acid.7.3 1.0 N to 10.0 N Sodium Hydroxide.7.4 Gold Chloride (HAuCI4) Solution, approximately 5 %,in reagent grade wate
19、r. Gold chloride in phosphoric acid also issuitable.7.5 Platinum Chloride (H2PtC16) Solution, approximately5 %, in reagent grade water. Platinum chloride in phosphoricacid also is suitable.7.6 Authenticated Amphetamine Standard.7.7 Authenticated Methamphetamine Standard.8. Calibration and Standardiz
20、ation8.1 The reagents utilized for these microcrystal tests are tobe tested for reliability using authenticated amphetamine andmethamphetamine standards and negative controls followingthe prescribed procedure. Only when it is determined that thereagents are producing the expected response may the re
21、agentsbe used in the testing procedure.9. Procedure9.1 Gold Chloride:9.1.1 Place a small sample, a few particles of powder, lessthan 1 mg, of the suspected methamphetamine or amphetamineon a microscope slide.9.1.2 Dissolve the sample in a few microdrops of 10 %hydrochloride acid or concentrated phos
22、phoric acid.NOTE 1The crystals tend to precipitate faster from the phosphoricacid. There also tends to be less interference when using the concentratedphosphoric acid.9.1.3 Add a few microdrops of 5 % gold chloride to theedge of the acid solution on the microscope slide.9.1.4 Observe the formation o
23、f the crystals using a properlyaligned and adjusted light microscope. This observation can bedone between crossed polars if desired. If crossed polars are tobe used, orient the polarizer in the east-west direction and theanalyzer in the north-south direction, verified by a blackbackground.9.1.5 The
24、crystals formed will depend on the drug present,as well as, the optical isomer present for the drug. Theformations that can be expected for methamphetamine andamphetamine are as follows.9.1.5.1 d- or l-Amphetamine, produces long yellow rods orblades.9.1.5.2 d, l- Amphetamine, produces irregular blad
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME19692006STANDARDGUIDEFORMICROCRYSTALTESTINGINTHEFORENSICANALYSISOFMETHAMPHETAMINEANDAMPHETAMINE

链接地址:http://www.mydoc123.com/p-529948.html