《ASTM E1233 E1233M-2014 Standard Test Method for Structural Performance of Exterior Windows Doors Skylights and Curtain Walls by Cyclic Air Pressure Differential《采用循环空气压差法测定外部窗 门 天窗.pdf》由会员分享,可在线阅读,更多相关《ASTM E1233 E1233M-2014 Standard Test Method for Structural Performance of Exterior Windows Doors Skylights and Curtain Walls by Cyclic Air Pressure Differential《采用循环空气压差法测定外部窗 门 天窗.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1233 06E1233/E1233M 14Standard Test Method forStructural Performance of Exterior Windows, Doors,Skylights, and Curtain Walls by Cyclic Air PressureDifferential1This standard is issued under the fixed designation E1233;E1233/E1233M; the number immediately following the designation indic
2、atesthe year of original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the determinatio
3、n of the structural performance of exterior windows, doors, skylights, and curtainwalls under cyclic air pressure differential, using a test chamber. This test method is applicable to all curtain wall assemblies,including, but not limited to, metal, glass, masonry, and stone components.21.2 This tes
4、t method is intended only for evaluating the structural performance associated with the specified test specimen, andnot the structural performance of adjacent construction.1.3 Procedure A shall be used for life cycle test loads.1.4 Procedure B shall be used for wind event test loads.1.5 The values s
5、tated in either SI units or inch-pound units are to be regarded separately as the standard. The values given inparentheses are for information only. stated in each system may not be exact equivalents; therefore, each system shall be usedindependently of the other. Combining values from the two syste
6、ms may result in non-conformance with the standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of r
7、egulatorylimitations prior to use. Specific hazard statements are given in Section 7.1.7 The text of this test method references notes and footnotes that provide explanatory materials. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of the sta
8、ndard.2. Referenced Documents2.1 ASTM Standards:3E330E330/E330M Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls byUniform Static Air Pressure DifferenceE631 Terminology of Building ConstructionsE997 Test Method for Structural Performance of Glass in Ext
9、erior Windows, Curtain Walls, and Doors Under the Influence ofUniform Static Loads by Destructive MethodsE998 Test Method for Structural Performance of Glass in Windows, Curtain Walls, and Doors Under the Influence of UniformStatic Loads by Nondestructive MethodE1300 Practice for Determining Load Re
10、sistance of Glass in BuildingsE1886 Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted byMissile(s) and Exposed to Cyclic Pressure DifferentialsE1996 Specification for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protect
11、ive Systems Impacted byWindborne Debris in Hurricanes1 This test method is under the jurisdiction ofASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.51 on Performanceof Windows, Doors, Skylights and Curtain Walls.Current edition approved April 1, 20
12、06Jan. 1, 2014. Published April 2006January 2014. Originally approved in 1988. Last previous edition approved in 20002006 asE1233 00.E1233 06. DOI: 10.1520/E1233-06.10.1520/E1233_E1233M-14.2 Additional information on curtain wall assemblies can be obtained from the American Architectural Manufacture
13、rs Association, Manufacturers Association (AAMA),1827 Walden Office Square, Suite 550, Schaumburg, IL 60173.60173-4268, http:/www.aamanet.org.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolu
14、me information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequ
15、ately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohock
16、en, PA 19428-2959. United States12.2 ASCEASCE/SEI Standard:4ASCE 7 (formerly ANSI A58.1)ASCE/SEI 7 Minimum Design Loads for Buildings and Other Structures3. Terminology3.1 DefinitionsDefinitions are in accordance with Terminology E631, unless otherwise indicated.3.2 Definitions of Terms Specific to
17、This Standard:3.2.1 design wind load, nthe uniform static air pressure differences, inward and outward, for which the specimen would bedesigned under service load conditions using conventional wind engineering specifications and concepts, expressed in pascals(oror pounds-force per square foot).foot.
18、 This pressure is determined by either analytical or wind-tunnel procedures (such as arespecified in ASCEASCE/SEI 7).3.2.2 one cycle, nbeginning at a specified air pressure differential, the application of positive (negative) pressure to achieveanother specified air pressure differential and returni
19、ng to the initial specified air pressure differential.3.2.3 permanent deformation, ndisplacement or change in dimension of the specimen after the applied load has been removedand the specimen has relaxed for the specified period of time.3.2.4 positive (negative) cyclic test load, nthe specified diff
20、erential in static air pressure, creating an inward (outward) loading,for which the specimen is to be tested under repeated conditions, expressed in pascals (oror pounds-force per square foot).foot.3.2.5 positive (negative) maximum test load, nthe specified differential in static air pressure, creat
21、ing an inward (outward)load, for which the specimen is to be tested for required minimum ultimate strength, expressed in pascals (oror pounds-force persquare foot). foot.3.2.6 stick system, na curtain wall assembly composed of individually framed continuous members, vertical mullions, andhorizontal
22、rails that are installed in a sequential, piece-by-piece process. The completed system is assembled entirely in the field.3.2.7 structural distress, na change in condition of the specimen indicative of deterioration under repeated load or incipientfailure, such as cracking, fastener loosening, local
23、 yielding, or loss of adhesive bond.3.2.8 test specimen, nthe entire assembled unit submitted for test (as described in Section 8).3.2.9 unit/panel system, na curtain wall assembly composed of pre-assembled groups of individual framing members. Thecompleted system is designed to be modular, transpor
24、table, and installed as a finished assembly.4. Summary of Test Method4.1 This test method consists of sealing the test specimen into or against one face of a test chamber, supplying air to orexhausting air from the chamber in accordance with a specific test loading program at the rate required to ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1233E1233M2014STANDARDTESTMETHODFORSTRUCTURALPERFORMANCEOFEXTERIORWINDOWSDOORSSKYLIGHTSANDCURTAINWALLSBYCYCLICAIRPRESSUREDIFFERENTIAL

链接地址:http://www.mydoc123.com/p-528226.html