ASTM C617 C617M-2012 Standard Practice for Capping Cylindrical Concrete Specimens《处理圆柱形混凝土试样顶部的标准实施规程》.pdf
《ASTM C617 C617M-2012 Standard Practice for Capping Cylindrical Concrete Specimens《处理圆柱形混凝土试样顶部的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C617 C617M-2012 Standard Practice for Capping Cylindrical Concrete Specimens《处理圆柱形混凝土试样顶部的标准实施规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C617/C617M 11 C617/C617M 12Standard Practice forCapping Cylindrical Concrete Specimens1This standard is issued under the fixed designation C617/C617M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This practice covers apparatus, materials,
3、and procedures for capping freshly molded concrete cylinders with neat cementand hardened cylinders and drilled concrete cores with high-strength gypsum paste or sulfur mortar.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in
4、 eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. I
5、t is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For specific precaution statements see 4.3.1 and 6.2.4.1.2. Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method f
6、or Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube Specimens)C150 Specification for Portland CementC472 Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum ConcreteC595 Specification for Blended Hydraulic CementsC1231/C1231M Practice for Use of Unbonde
7、d Caps in Determination of Compressive Strength of Hardened Concrete Cylinders2.2 ANSI Standard:3B46.1 Standard for Surface Texture (Surface, Roughness, Waviness and Lay)3. Significance and Use3.1 This practice describes procedures for providing plane surfaces on the ends of freshly molded concrete
8、cylinders, hardenedcylinders, or drilled concrete cores when the end surfaces do not conform with the planeness and perpendicularity requirementsof applicable standards. Practice C1231/C1231M describes alternative procedures using unbonded caps or pad caps.4. Capping Equipment4.1 Capping PlatesNeat
9、cement caps and high-strength gypsum-paste caps shall be formed against a glass plate at least 6 mm14 in. thick, a machined metal plate at least 11 mm 0.45 in. thick, or a polished plate of granite or diabase at least 75 mm 3in. thick. Sulfur mortar caps shall be formed against similar metal or ston
10、e plates except that the recessed area which receivesmolten sulfur shall not be deeper than 12 mm 12 in. In all cases, plates shall be at least 25 mm 1 in. greater in diameter thanthe test specimen and the working surfaces shall not depart from a plane by more than 0.05 mm 0.002 in. in 150 mm 6 in.
11、Thesurface roughness of newly finished metal plates shall not exceed that set forth in Table 4 of American National Standard B46.1,or 3.2 m 125 in. for any type of surface and direction of lay. The surface, when new, shall be free of gouges, grooves, or1 This practice is under the jurisdiction of AS
12、TM Committee C09 on Concrete and Concrete Aggregatesand is the direct responsibility of Subcommittee C09.61 on Testingfor Strength.Current edition approved Aug. 1, 2011Nov. 15, 2012. Published September 2011December 2012. Originally approved in 1968. Last previous edition approved in 20102011as C617
13、10.11. DOI: 10.1520/C0617_C0617M-11.10.1520/C0617_C0617M-12.2 For referenced ASTM standards, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM websit
14、e.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version.
15、Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section a
16、ppears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1indentations beyond those caused by the finishing operation. Metal plates that have been in use shall be free of gouges, grooves,and indentations greate
17、r than 0.25 mm 0.010 in. deep or greater than 30 mm2 0.05 in.2 in surface area.NOTE 1A Rockwell hardness of 48 HRC is suggested for capping plates of devices used to form sulfur mortar caps.4.2 Alignment DevicesSuitable alignment devices, such as guide bars or bulls-eye levels, shall be used in conj
18、unction withcapping plates to ensure that no single cap will depart from perpendicularity to the axis of a cylindrical specimen by more than0.5 (approximately(See Note 2equivalent to 3 mm in 300 mm ). 18 in. in 12 in.). The same requirement is applicable to therelationship between the axis of the al
19、ignment device and the surface of a capping plate when guide bars are used. In addition, thelocation of each bar with respect to its plate must be such that no cap will be off-centered on a test specimen by more than 2 mm116 in.NOTE 2A deviation from perpendicularity of 0.5 is equal to a slope of ap
20、proximately 1 mm in 100 mm 18 in. in 12 in.4.3 Melting Pots for Sulfur MortarsPots used for melting sulfur mortars shall be equipped with automatic temperaturecontrols and shall be made of metal or lined with a material that is nonreactive with molten sulfur.4.3.1 WarningMelting pots equipped with p
21、eripheral heating will ensure against accidents during reheating of cooled sulfurmixture that have a crusted-over surface. When using melting pots not so equipped, a build-up of pressure under the hardenedsurface crust on subsequent reheating may be avoided by use of a metal rod that contacts the bo
22、ttom of the pot and projects abovethe surface of the fluid sulfur mix as it cools. The rod should be of sufficient size to conduct enough heat to the top on reheatingto melt a ring around the rod first and thus avoid the development of pressure. A large metal ladle can be substituted for the rod.4.3
23、.1.1 Use sulfur melting pots in a hood to exhaust the fumes to outdoors. Heating over an open flame is dangerous becausethe flash point of sulfur is approximately 207 C 405 F and the mixture can ignite due to overheating. If the mixture starts toburn, covering will snuff out the flame. Recharge the
24、pot with fresh material after the flame has been extinguished.5. Capping Materials5.1 The strength of the capping material and the thickness of the caps shall conform to the requirements of Table 1.5.1.1 If sulfur mortar, high strength gypsum paste and other materials except neat cement paste are to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC617C617M2012STANDARDPRACTICEFORCAPPINGCYLINDRICALCONCRETESPECIMENS 处理 圆柱形 混凝土 试样 顶部 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-507785.html