ASTM C617-2010 Standard Practice for Capping Cylindrical Concrete Specimens《为圆柱形混凝土试件加盖的标准实施规程》.pdf
《ASTM C617-2010 Standard Practice for Capping Cylindrical Concrete Specimens《为圆柱形混凝土试件加盖的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C617-2010 Standard Practice for Capping Cylindrical Concrete Specimens《为圆柱形混凝土试件加盖的标准实施规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C617 10Standard Practice forCapping Cylindrical Concrete Specimens1This standard is issued under the fixed designation C617; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parent
2、heses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This practice covers apparatus, materials, and proce-dures for cappin
3、g freshly molded concrete cylinders with neatcement and hardened cylinders and drilled concrete cores withhigh-strength gypsum paste or sulfur mortar.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that
4、are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the appl
5、ica-bility of regulatory limitations prior to use. For specificprecaution statements see 4.3.1 and 6.2.4.1.2. Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method for Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C150 Specification for Portland CementC
6、472 Test Methods for Physical Testing of Gypsum, Gyp-sum Plasters and Gypsum ConcreteC595 Specification for Blended Hydraulic CementsC1231/C1231M Practice for Use of Unbonded Caps inDetermination of Compressive Strength of Hardened Con-crete Cylinders2.2 ANSI Standard:3B46.1 Standard for Surface Tex
7、ture (Surface, Roughness,Waviness and Lay)3. Significance and Use3.1 This practice describes procedures for providing planesurfaces on the ends of freshly molded concrete cylinders,hardened cylinders, or drilled concrete cores when the endsurfaces do not conform with the planeness and perpendicu-lar
8、ity requirements of applicable standards. Practice C1231/C1231M describes alternative procedures using unbonded capsor pad caps.4. Capping Equipment4.1 Capping PlatesNeat cement caps and high-strengthgypsum-paste caps shall be formed against a glass plate at least14 in. (6 mm) thick, a machined meta
9、l plate at least 0.45 in. (11mm) thick, or a polished plate of granite or diabase at least 3in. (76 mm) thick. Sulfur mortar caps shall be formed againstsimilar metal or stone plates except that the recessed areawhich receives molten sulfur shall not be deeper than12 in.(12 mm). In all cases, plates
10、 shall be at least 1 in. (25 mm)greater in diameter than the test specimen and the workingsurfaces shall not depart from a plane by more than 0.002 in.(0.05 mm) in 6 in. (152 mm). The surface roughness of newlyfinished metal plates shall not exceed that set forth in Table 4of American National Stand
11、ard B46.1, or 125 in. (3.2 m) forany type of surface and direction of lay. The surface, whennew, shall be free of gouges, grooves, or indentations beyondthose caused by the finishing operation. Metal plates that havebeen in use shall be free of gouges, grooves, and indentationsgreater than 0.010 in.
12、 (0.25 mm) deep or greater than 0.05in.2(32 mm2) in surface area.NOTE 1A Rockwell hardness of 48 HRC is suggested for cappingplates of devices used to form sulfur mortar caps.4.2 Alignment DevicesSuitable alignment devices, suchas guide bars or bulls-eye levels, shall be used in conjunctionwith capp
13、ing plates to ensure that no single cap will departfrom perpendicularity to the axis of a cylindrical specimen bymore than 0.5 (approximately equivalent to18 in. in 12 in.(3.2 mm in 305 mm). The same requirement is applicable to1This practice is under the jurisdiction of ASTM Committee C09 on Concre
14、teand ConcreteAggregates and is the direct responsibility of Subcommittee C09.61 onTesting for Strength.Current edition approved June 15, 2010. Published July 2010. Originallyapproved in 1968. Last previous edition approved in 2009 as C61709a. DOI:10.1520/C0617-10.2For referenced ASTM standards, vis
15、it the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York
16、, NY 10036, http:/www.ansi.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the relationship between the axis of the alignment device andthe surface of a capping pl
17、ate when guide bars are used. Inaddition, the location of each bar with respect to its plate mustbe such that no cap will be off-centered on a test specimen bymore than116 in. (2 mm).4.3 Melting Pots for Sulfur MortarsPots used for meltingsulfur mortars shall be equipped with automatic temperatureco
18、ntrols and shall be made of metal or lined with a material thatis nonreactive with molten sulfur.4.3.1 WarningMelting pots equipped with peripheralheating will ensure against accidents during reheating ofcooled sulfur mixture that have a crusted-over surface. Whenusing melting pots not so equipped,
19、a build-up of pressureunder the hardened surface crust on subsequent reheating maybe avoided by use of a metal rod that contacts the bottom of thepot and projects above the surface of the fluid sulfur mix as itcools. The rod should be of sufficient size to conduct enoughheat to the top on reheating
20、to melt a ring around the rod firstand thus avoid the development of pressure.Alarge metal ladlecan be substituted for the rod.4.3.1.1 Use sulfur melting pots in a hood to exhaust thefumes to outdoors. Heating over an open flame is dangerousbecause the flash point of sulfur is approximately 440 F (2
21、27C) and the mixture can ignite due to overheating. Should themixture start to burn, covering will snuff out the flame. The potshould be recharged with fresh material after the flame hasbeen extinguished.5. Capping Materials5.1 The strength of the capping material and the thickness ofthe caps shall
22、conform to the requirements of Table 1.5.1.1 If sulfur mortar, high strength gypsum paste and othermaterials except neat cement paste are to be used to testconcrete with a strength greater than 7000 psi (50 MPa) andtheir compressive strength is less than the cylinder compressivestrength, the manufac
23、turer or the user of the material mustprovide documentation:5.1.1.1 That the average strength of 15 cylinders cappedwith the material is not less than 98 percent of the averagestrength of 15 companion cylinders capped with neat cementpaste or 15 cylinders ground plane to within 0.002 in. (0.05mm).5.
24、1.1.2 That the standard deviation of the strengths of thecapped cylinders is not greater than 1.57 times that of thestandard deviation of the reference cylinders.5.1.1.3 That the cap thickness requirements were met in thequalification tests, and5.1.1.4 Of the hardening time of the caps used in thequ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6172010STANDARDPRACTICEFORCAPPINGCYLINDRICALCONCRETESPECIMENS 圆柱形 混凝土 加盖 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-507790.html