1、Designation: C614 10 (Reapproved 2015)Standard Test Method forAlkali Resistance of Porcelain Enamels1This standard is issued under the fixed designation C614; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONAlthough all porcelain enamels are highly resistant to attack by cold alkaline solutions, somecompositions are affected by hot sol
3、utions of the type encountered in automatic laundry anddishwashing equipment. Tests to eliminate porcelain enamels of poor resistance have been developedand used by various laboratories. In general, these tests consist of subjecting specimens to a boilingsolution of either sodium pyrophosphate or so
4、dium hydroxide for a period of two or more hours. Thespecimens are weighed before and after exposure to the test treatment and the loss-in-weight is takenas a measure of alkali attack. In some tests representing milder exposure conditions, the 45 degreespecular gloss is measured before and after exp
5、osure and the percentage of initial gloss retained is usedas an indicator of alkali resistance. While such tests have served a useful purpose in developing moreresistant porcelain enamel compositions and in manufacturing control operations, agreement betweenlaboratories has left something to be desi
6、red. The present test was designed to provide thereproducibility between laboratories that is so essential to any standard test procedure.1. Scope1.1 This test method2covers the measurement of the resis-tance of a porcelain enamel to a hot solution of tetrasodiumpyrophosphate. Although the specific
7、alkali mentioned hereinis tetrasodium pyrophosphate the equipment and techniques areequally applicable to other alkali solutions.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for info
8、rmation onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulat
9、ory limitations prior to use.2. Significance and Use2.1 This test method is intended specifically for testing theresistance to alkaline attack of porcelain enamels to be used asa final finish on washing machines, dishwashers, combinationwasher-dryers, and similar appliances where the surface isnorma
10、lly exposed to an alkaline environment at elevatedtemperatures.3. Apparatus3.1 Test Chamber, of a type illustrated in Fig. 1, Fig. 3, andFig. 6. This part of the equipment consists of a stainless steelbeaker fitted with an O-ring sealed cover which supports animmersion heater, a stirring device, the
11、rmometer and thermis-tor wells; three specimen holders; a reflux condenser; a flowchanneling shield to slide over and be supported by theimmersion heater; and a stirring motor.3The beaker, heatersheath, stirring device, thermometer and thermistor wells,specimen holders, and the flow channeling shiel
12、d shall be madefrom stainless steel alloys from the AISI 300 Series.3.2 Temperature Controller, thermistor-actuated, capable ofmaintaining the temperature of the alkali solution in the beakerat 96.00 6 0.20C.3.3 Thermometer, calibrated, approximately 15 in. (380mm) long and932 in. (7.1 mm) in diamet
13、er, with 0.1 divisions.3.4 Drying Oven, electrically heated.3.5 Balance, having a sensitivity of 0.1 mg and a capacity ofnot less than 200 g.1This test method is under the jurisdiction ofASTM Committee B08 on Metallicand Inorganic Coatings and is the direct responsibility of Subcommittee B08.12 onMa
14、terials for Porcelain Enamel and Ceramic-Metal Systems.Current edition approved May 1, 2015. Published May 2015. Originallyapproved in 1968. Last previous edition approved in 2011 as C614 10(2011). DOI:10.1520/C0614-10R15.2This test was developed at the National Bureau of Standards under thesponsors
15、hip of The Porcelain Enamel Institute, Inc., and published as P. E. I.Bulletin T-25.3See the appendix for drawings of the equipment. This equipment may bepurchased from the Hoover Instrument Service, Inc., 401 N. Home Rd., Mansfield,OH 44906.Copyright ASTM International, 100 Barr Harbor Drive, PO Bo
16、x C700, West Conshohocken, PA 19428-2959. United States13.6 Desiccator.3.7 Hot Plate, or burner suitable for heating the test solu-tion.3.8 Sponge, soft, cellulose.3.9 Aluminum Alloy Sheets, approximately 312 by 312 by18in. (89 by 89 by 3.1 mm).4. Reagents and Materials4.1 Tetrasodium Pyrophosphate,
17、 hydrated (Na4P2O710H2O), recrystallized, reagent grade.4.2 Trisodium Phosphate (Na3PO412H2O).5. Test Specimens5.1 Preparation of Specimens The test specimens shallbe 312 in. (89 mm) square and may be prepared by enamelingmetal blanks of that size or by cutting from a larger piece.Hanging holes, if
18、necessary for firing or weighing or both, maybe placed at the corners. The specimens shall be sufficiently flatto permit sealing in the holders. The edges of cut specimensshall be stoned or filed to remove any sharp or loosely adheringfragments of metal or porcelain enamel. It is recommended thatthe
19、 specimens be permanently marked on the back side foridentification.5.2 Number of SpecimensSix specimens shall be testedsimultaneously.5.3 Cleaning of Specimens Before Alkali Exposure Thespecimens shall be rinsed with running tap water and washedwith a soft cellulose sponge dampened with a 1 % solut
20、ion oftrisodium phosphate. A light pressure and a back-and-forthmotion in two directions, 90 apart, shall be used in thewashing.After washing, the specimens shall be rinsed first withrunning tap water, next with distilled water and then allowed todrain in a near vertical position prior to oven-dryin
21、g at 110Cfor 15 min. The specimens shall be cooled in a desiccator for30 min prior to weighing.5.4 Weighing of Test SpecimensThe specimens shall beweighed immediately upon removal from the desiccator.Weights shall be recorded to 0.0001 g. The weighed specimensshall be stored in a desiccator until te
22、sted.6. Procedure6.1 Preparation of Test SolutionPrepare the test solutionby adding 260 g of tetrasodium pyrophosphate to 4.940 litresof distilled water. Pour the entire amount of prepared solutioninto the beaker and cover the rectangular slots with lids. Use afreshly prepared solution for each set
23、of six specimens.6.2 Preheating Test SolutionPlace the temperature con-troller and stirrer in operation and preheat the solution to 96C.Heating may be expedited by placing the beaker on a hot plateor over a gas burner. When a temperature near 96C has beenreached, remove the beaker from the hot plate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC61420102015STANDARDTESTMETHODFORALKALIRESISTANCEOFPORCELAINENAMELS 搪瓷 强碱 腐蚀 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-507775.html