ASTM D7347-2007 Standard Test Method for Determination of Olefin Content in Denatured Ethanol by Supercritical Fluid Chromatography《用超临界流体色谱法测定变性乙醇中石蜡含量的标准试验方法》.pdf
《ASTM D7347-2007 Standard Test Method for Determination of Olefin Content in Denatured Ethanol by Supercritical Fluid Chromatography《用超临界流体色谱法测定变性乙醇中石蜡含量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7347-2007 Standard Test Method for Determination of Olefin Content in Denatured Ethanol by Supercritical Fluid Chromatography《用超临界流体色谱法测定变性乙醇中石蜡含量的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7347 07An American National StandardStandard Test Method forDetermination of Olefin Content in Denatured Ethanol bySupercritical Fluid Chromatography1This standard is issued under the fixed designation D 7347; the number immediately following the designation indicates the year oforigi
2、nal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the totalamount of
3、 olefins in denatured ethanol to be used as anoxygenate additive in blended spark ignition engine fuels. Themethod of determination is supercritical fluid chromatography(SFC). The application range is from 0.1 to 1.0 mass percenttotal olefins. Results are expressed in terms of mass percentolefins.1.
4、2 This test method can be used for the analysis ofdenatured ethanol that is intended to be used as an oxygenateadditive in commercial spark ignition engine fuels.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This stan
5、dard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 A
6、STM Standards:2D 4052 Test Method for Density and Relative Density ofLiquids by Digital Density MeterD 5186 Test Method for Determination of the AromaticContent and PolynuclearAromatic Content of Diesel Fuelsand Aviation Turbine Fuels By Supercritical Fluid Chro-matographyD 6550 Test Method for Dete
7、rmination of Olefin Content ofGasolines by Supercritical-Fluid Chromatography3. Terminology3.1 Definitions:3.1.1 critical pressure, nthat pressure needed to condensea gas at the critical temperature.3.1.2 critical temperature, nhighest temperature at whicha gaseous fluid can be converted to a liquid
8、 by means ofcompression.3.1.3 supercritical fluid, nfluid maintained in a thermo-dynamic state above its critical temperature and critical pres-sure.3.1.4 supercritical fluid chromatography, nclass of chro-matography that employs supercritical fluids as mobile phases.4. Summary of Test Method4.1 A s
9、mall aliquot of the denatured alcohol sample isinjected onto a set of three analytical chromatographic columnsconnected in series. The sample is transported through thecolumns using supercritical carbon dioxide (CO2)asthemobile phase. The first column is packed with polyvinylalcohol (PVA). The secon
10、d column in the series is an analyticalcolumn packed with high surface area silica gel particles, andthe third column is packed with silica particles coated withstrong cation exchange material loaded with silver ions.4.2 Two six-port switching valves are used to direct thedifferent classes of compon
11、ents through the chromatographicsystem to the detector. In a forward flow mode, saturates,aromatics, and olefins pass onto the analytical silica gel columnwhile the alcohol is retained on the PVAcolumn. The saturates,aromatics, and olefins are maintained on the silica column,while the alcohol is bac
12、k-flushed to the detector. This step freesthe flow path of alcohol species allowing for the separation ofthe olefins from saturates and aromatics. The forward flowmode is resumed after the alcohol is eliminated and saturatesare carried to the detector, while the aromatics are retained onthe silica c
13、olumn and the olefinic species are trapped on thesilver-loaded column. The next step is to back-flush the olefinsfrom the silver-loaded column to the detector. Finally thearomatics are carried from the silica column to the detector ina forward flow mode, bypassing the silver-loaded column.1This test
14、 method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04.0C on Liquid Chromatography.Current edition approved Aug. 1, 2007. Published September 2007.2For referenced ASTM standards, visit the ASTM website, www.a
15、stm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3 A f
16、lame ionization detector (FID) is used for quantita-tion. Calibration is based on the area of the chromatographicsignal for olefins, relative to standard reference materials,which contain a known mass percent of total olefins ascorrected for density.5. Significance and Use5.1 Olefinic hydrocarbons t
17、hat may be present in denaturedethanol have been demonstrated to contribute to photochemicalreactions in the atmosphere, and this can result in the formationof smog in susceptible urban areas.5.2 The California Air Resources Board (CARB) has speci-fied a maximum allowable limit of total olefins in s
18、parkignition engine fuel. Denatured ethanol will be added at theterminals as an oxygenate additive and can contain olefinicspecies contributing to the total olefins present in spark ignitionengine fuel. An analytical method is therefore necessary todetermine total olefins in denatured ethanol intend
19、ed for sparkignition engine fuel use. The test method is intended to be usedby both regulators and producers.5.3 The present test method is automated, does not requireany sample preparation, and has a relatively short analysis timeof approximately 20 min.6. Apparatus6.1 Supercritical Fluid Chromatog
20、raph (SFC)Any SFCinstrumentation can be used that has the following character-istics and meets the performance requirements specified inSection 8.NOTE 1SFC instruments suitable for Test Method D 6550 are suitablefor this test method if equipped with a second column heater as describedin 6.1.5.1 and
21、columns as described in 6.1.4.6.1.1 PumpThe SFC pump shall be able to operate at therequired pressures (typically up to about 30 MPa) and delivera sufficiently stable flow to meet the requirements of retentiontime precision (better than 0.3%) and detection background(Section 8). The characteristics
22、of the pump largely determinethe optimum column diameters. Columns with an insidediameter of 1.0-mm ID require a pump flow capacity ofapproximately 50-L/min of liquid carbon dioxide, whereascolumns with an inside diameter of 4.6-mm require a pumpcapacity of at least 1-mL/min of liquid carbon dioxide
23、.6.1.2 DetectorsA flame-ionization detector (FID) is re-quired for quantitation. A flow restrictor shall be installedimmediately before the FID. The restrictor serves to maintainthe required pressure in the column, while allowing the pumpand detector to perform as specified in 8.2.6.1.3 Sample Inlet
24、 SystemA liquid-sample injection valveis required that is capable of introducing a sub-microlitervolume with a precision better than 0.5%. A 0.200 to 0.060-Linjection volume was found to be adequate in combination with1-mm diameter columns. The sample inlet system shall beinstalled and operated in a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD73472007STANDARDTESTMETHODFORDETERMINATIONOFOLEFINCONTENTINDENATUREDETHANOLBYSUPERCRITICALFLUIDCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-525238.html