ASTM D7161-2005 Standard Practice for Determination of Real Time Expiration Dating of Mature Medical Gloves Stored Under Typical Warehouse Conditions《在常规仓库条件下到期医用手套实时有效期测定的标准实施规程》.pdf
《ASTM D7161-2005 Standard Practice for Determination of Real Time Expiration Dating of Mature Medical Gloves Stored Under Typical Warehouse Conditions《在常规仓库条件下到期医用手套实时有效期测定的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7161-2005 Standard Practice for Determination of Real Time Expiration Dating of Mature Medical Gloves Stored Under Typical Warehouse Conditions《在常规仓库条件下到期医用手套实时有效期测定的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7161 05Standard Practice forDetermination of Real Time Expiration Dating of MatureMedical Gloves Stored Under Typical WarehouseConditions1This standard is issued under the fixed designation D 7161; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers all surgeons and examinationgloves, made from either s
3、ynthetic or natural rubber latex,marketed at the time this practice is published, for which thereis no previous real time aging data available, and for whichthere are at least 12 months of storage as finished goods undertypical warehouse conditions. This practice describes how todevelop real time ag
4、ing data for gloves that are part of finishedgoods inventory (including gloves that may no longer bemanufactured) in order to verify the estimated expiration date(see Note 1). Manufacturers may use this data as a startingpoint for real time aging studies as described in PracticeD 7160.NOTE 1Accelera
5、ted aging for three-year shelf life is described inPractice D 7160.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the ap
6、plica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 412 Test Methods for Vulcanized Rubber and Thermo-plastic ElastomersTensionD 3078 Test Method for Determination of Leaks in FlexiblePackaging by Bubble EmissionD 3577 Specification for Rubber Surgical Gl
7、ovesD 3578 Specification for Rubber Examination GlovesD 5151 Test Method for Detection of Holes in MedicalGlovesD 5250 Specification for Poly(vinyl chloride) Gloves forMedical ApplicationD 6319 Specification for Nitrile Examination Gloves forMedical ApplicationD 7160 Practice for Determination of Ex
8、piration Dating forMedical GlovesF88 Test Method for Seal Strength of Flexible BarrierMaterialsF 1929 Test Method for Detecting Seal Leaks in PorousMedical Packaging by Dye Penetration2.2 ISO Standard:ISO 2859 Sampling Procedures for Inspection by At-tributes33. Terminology3.1 Definitions of Terms S
9、pecific to This Standard:3.1.1 date of manufacturethe date of the final processingstep. For sterile products, the last processing step would besterilization.3.1.2 mature medical glovesthose that have at least 12months of storage as finished goods under warehouse condi-tions.3.1.3 real time expiratio
10、n datecalculated by adding theshelf life to the date of manufacture3.1.4 shelf lifedetermined by the longest storage intervalof the mature gloves (from the date of manufacture) for whichthere is data demonstrating that the product meets the specifi-cations defined in this practice. The data should b
11、e generatedutilizing the test plan and methods defined in this practice.4. Significance and Use4.1 This practice provides a study design for determiningshelf life of medical gloves using product in its final packagingconfiguration that has been stored under typical warehouseconditions.5. General Inf
12、ormation5.1 For each glove type to be evaluated for expirationdating, select not less than three (3) lots from finished goods1This practice is under the jurisdiction of ASTM Committee D11 on Rubber andis the direct responsibility of Subcommittee D11.40 on Consumer Rubber Products.Current edition app
13、roved June 15, 2005. Published August 2005.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from In
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD71612005STANDARDPRACTICEFORDETERMINATIONOFREALTIMEEXPIRATIONDATINGOFMATUREMEDICALGLOVESSTOREDUNDERTYPICALWAREHOUSECONDITIONS

链接地址:http://www.mydoc123.com/p-524668.html