ASTM D6961 D6961M-2009(2015)e1 8876 Standard Test Method for Color Measurement of Flax Fiber《亚麻纤维颜色测量的标准试验方法》.pdf
《ASTM D6961 D6961M-2009(2015)e1 8876 Standard Test Method for Color Measurement of Flax Fiber《亚麻纤维颜色测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6961 D6961M-2009(2015)e1 8876 Standard Test Method for Color Measurement of Flax Fiber《亚麻纤维颜色测量的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6961/D6961M 09 (Reapproved 2015)1Standard Test Method forColor Measurement of Flax Fiber1This standard is issued under the fixed designation D6961/D6961M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEThe Terminology section was updated in accordance with D13 policy.1. Scope1.1 This test method covers the instrumental color me
3、asure-ment of flax fiber.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may resul
4、t in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory li
5、mitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD1776 Practice for Conditioning and Testing TextilesD6798 Terminology Relating to Flax and LinenE284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects by Usingthe CIE Syste
6、mE1164 Practice for Obtaining Spectrometric Data for Object-Color Evaluation2.2 Other Standard:AATCC Evaluation Procedure 6 Instrumental Color Mea-surement33. Terminology3.13.2 For all terminology related to Flax see TerminologyD6798.3.2.1 The following terms are relevant to this standard:dew-rettin
7、g, enzyme-retting, and water-retting.3.3 For other textile terminology, see Terminology D123.4. Summary of Test Method4.1 Samples of flax fiber are presented to a color spectro-photometer. Color measurements are taken through a largeaperture port 25.4 millimeter 1-in. diameter, in order toaverage ov
8、er the natural color variation that occurs in flax fiber.The instrument aperture is fitted with a quartz window. Thewindow serves two functions, namely, to provide a base forcompacting the sample during measurement, and to protect theinstrument from accumulation of stray fiber particles. CIELABL*, a
9、*, and b* measurements are taken and are instrumentallycalculated from tristimulus X, Y and Z data, observer function,and illuminant data.5. Significance and Use5.1 Few standards exist to objectively judge flax quality.Color is an important factor in the quality of flax fiber. Naturalvariations in r
10、aw flax fiber, various processing steps, fiberblending, and a wide range of end uses contribute to the needfor a standard method of objectively measuring the color offlax fiber. Spectrophotometic data provide an accurate, precisedetermination of the color of flax fiber. Colorimetric data areobtained
11、 through specimen measurement by combining speci-men spectral data with data representing a CIE standardobserver and a CIE standard illuminant, as described inMethod E308.5.2 If there are differences of practical significance betweenreported test results for two (or more) laboratories, compara-tive
12、tests should be performed to determine if there is astatistical bias between them, using competent statistical assis-tance. As a minimum, use the samples for such a comparativetest that are as homogeneous as possible, drawn from the samelot of material as the samples that resulted in disparate resul
13、tsduring initial testing and randomly assigned in equal numbersto each laboratory. The results from the laboratories involvedshould be compared using a statistical test for unpaired data, aprobability level chosen prior to the testing series. If a bias is1This test method is under the jurisdiction o
14、f ASTM Committee D13 on Textilesand is the direct responsibility of Subcommittee D13.17 on Flax and Linen.Current edition approved Feb. 1, 2015. Published April 2015. Originallyapproved in 2003. Last previous edition approved in 2009 as D696109. DOI:10.1520/D6961_C6961M-09(15)E01.2For referenced AST
15、M standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American Association of Textile Chemists and Colorists(AATCC), P
16、.O. Box 12215, Research Triangle Park, NC 27709, http:/www.aatcc.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1found, either its cause must be found and corrected, or futuretest results for that fiber sample type must be adjuste
17、d inconsideration of the known bias.6. Apparatus6.1 A visible range spectrophotometer (minimum of 20-point) is recommended. Such an instrument provides greateraccuracy than colorimeters, spectro-colorimeters, or 10-pointcolor spectrophotometers.6.1.1 Instrument Configuration and Settings:46.1.1.1 Ei
18、ther a 0/45 or a spherical instrument/specimengeometry may be used. The selected geometry should beincluded in the report.6.1.1.2 If the instrument offers a choice of specular modes,measurements should be taken using the specular excludedmode.6.1.1.3 Use the recommended CIE Illuminant D65 unlessothe
19、rwise specified in a material specification or contract order.If an alternate illuminant is selected, its specifications shouldbe included in the report.6.1.1.4 Use the recommended CIE 10-degree observer un-less otherwise specified in a material specification or contractorder. If an alternate illumi
20、nant is selected, its specificationsshould be included in the report.6.2 A fiber compression cell capable of applying air pres-sure of 206,843 Pa 30 psi or 275,790 Pa 40 psi isrecommended for assuring consistent pressure among speci-mens presented for measurement.7. Sampling and Sample Preparation7.
21、1 For acceptance testing, take a lot of sample fromshipping containers as directed in an applicable specification,or as agreed upon between the purchaser and supplier.7.2 Take the measurement at a minimum of five sites withina specimen and three measurements at each site. Means of thethree readings
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6961D6961M20092015E18876STANDARDTESTMETHODFORCOLORMEASUREMENTOFFLAXFIBER 亚麻 纤维 颜色 测量 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-524095.html