ASTM D6676 D6676M-2013 8265 Standard Test Method for Cathodic Disbonding of Exterior Pipeline Coatings at Elevated Temperatures Using Interior Heating《用内部加热测定高温下外部管道镀层的阴极断接的标准试验方法》.pdf
《ASTM D6676 D6676M-2013 8265 Standard Test Method for Cathodic Disbonding of Exterior Pipeline Coatings at Elevated Temperatures Using Interior Heating《用内部加热测定高温下外部管道镀层的阴极断接的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6676 D6676M-2013 8265 Standard Test Method for Cathodic Disbonding of Exterior Pipeline Coatings at Elevated Temperatures Using Interior Heating《用内部加热测定高温下外部管道镀层的阴极断接的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6676/D6676M 13Standard Test Method forCathodic Disbonding of Exterior Pipeline Coatings atElevated Temperatures Using Interior Heating1This standard is issued under the fixed designation D6676/D6676M; the number immediately following the designation indicates theyear of original adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes an accelerated procedure fordetermining compara
3、tive characteristics of coating systemsapplied to the exterior of steel pipe for the purpose ofpreventing or mitigating corrosion that may occur in under-ground or immersion where the pipe is carrying heated mediaand is under cathodic protection. This test method is intendedfor use with samples of c
4、oated pipe, or with a specimen cutfrom the section of coated pipe or flat plates, and is applicableto such samples when the coating is characterized by functionas an electrical barrier.1.2 This test method is intended to simulate conditionswhen external coatings are exposed to high temperature insid
5、ethe pipe and to an ambient temperature outside, and thus aresubjected to temperature gradient. If elevated temperatures arerequired but without temperature gradient, see Test MethodG42.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values
6、stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its
7、use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2G8 Test Methods for Cathodic Disbonding of Pipeline Coat-ingsG12 Test Met
8、hod for Nondestructive Measurement of FilmThickness of Pipeline Coatings on SteelG42 Test Method for Cathodic Disbonding of PipelineCoatings Subjected to Elevated TemperaturesG62 Test Methods for Holiday Detection in Pipeline Coat-ingsG95 Test Method for Cathodic Disbondment Test of PipelineCoatings
9、 (Attached Cell Method)3. Summary of Test Method3.1 The test method described, subjects the coating on thetest specimen to electrical stress in a highly conductive alkalineelectrolyte. Electrical stress is obtained from an impresseddirect- current system. An intentional holiday is to be made inthe c
10、oating prior to starting of test.3.1.1 Electrical instrumentation is provided for measuringthe current and the potential throughout the test cycle. At theconclusion of the test period, the test specimen is physicallyexamined.3.1.2 Physical examination is conducted by comparing theextent of loosened
11、or disbonded coating at the intentionalholiday in the immersed area with extent of loosened ordisbonded coating at a reference holiday made in the coating inan area that was not immersed.3.1.3 The cathodic stress is applied under conditions of aconstant temperature gradient, simulating a heated pipe
12、linewith an exterior coating.3.1.4 Specimens that can be used are: (a) piece of pipe (Fig.1)or(b) samples cut from pipe or flat plate (Fig. 2 and Fig. 3).3.1.4.1 Some coatings rely on application tension (such astape) for maximum cathodic disbondment resistance. Cutcoupons or flat plates must not be
13、 used.4. Significance and Use4.1 Damage to a pipe coating is almost unavoidable duringtransportation and construction. Breaks or holidays in pipecoatings may expose the pipe to possible corrosion since, aftera pipe has been installed underground, the surrounding earthwill be moisture-bearing and wil
14、l constitute an effectiveelectrolyte. Applied cathodic protection potentials may cause1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.48 on Durability of Pipeline Coating a
15、nd Linings.Current edition approved Nov. 1, 2013. Published November 2013. Originallyapproved in 2001. Last previous edition approved in 2001 as D6676 011whichwas withdrawn January 2010 and reinstated in November 2013. DOI: 10.1520/D6676_D6676M-13.2For referenced ASTM standards, visit the ASTM websi
16、te, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
17、1loosening of the coating, beginning at holiday edges. Sponta-neous holidays may also be caused by such potentials. Usuallyexterior pipeline coatings applied over pipes carrying hotmedia (oil, gas) are exposed to high temperature inside the pipeand low temperature outside and subjected to temperatur
18、egradient. Heat flux is directed from metal (substrate) to thecoating. This test method provides accelerated conditions forcathodic disbondment to occur under simulated heating andprovides a measure of resistance of coatings to this type ofaction.4.2 The effects of the test are to be evaluated by ph
19、ysicalexaminations and monitoring the current drawn by the testspecimens. Usually there is no correlation between the twomethods of evaluation, but both methods are significant.Physical examination consists of assessing the effective contactof the coating with the metal surface in terms of observedd
20、ifferences in the relative adhesive bond. It is usually foundthat the cathodically disbonded area propagates from an areawhere adhesion is zero to an area where adhesion reaches theoriginal level.An intermediate zone of decreased adhesion mayalso be present.4.3 Assumptions associated with test resul
21、ts include:4.3.1 Maximum adhesion, or bond, is found in the coatingthat was not immersed in the test liquid, and4.3.2 Decreased adhesion in the immersed test area is theresult of cathodic disbondment.4.4 Ability to resist disbondment is a desired quality on acomparative basis, but disbondment in thi
22、s test method is notnecessarily an adverse indication of coating performance. Thevirtue of this test method is that all dielectric-type coatings nowin common use will disbond to some degree, thus providing ameans of comparing one coating to another.4.5 The amount of current flowing in the test cell
23、is arelative indicator of the extent of areas requiring protectionagainst corrosion; however, the current density appearing inthis test is much greater than that usually required for cathodicprotection in natural, inland soil environments.4.6 Test voltages higher than those recommended mayresult in
24、the formation of chlorine gas. The subsequent chemi-cal effects on the coating could cast doubt on the interpretationof the test results. Filter tube with fritted disk (see Test MethodG95) or layer of sand (40 mesh) put on the coated surface mayreduce this effect.5. Apparatus5.1 Test Vessel for Pipe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6676D6676M20138265STANDARDTESTMETHODFORCATHODICDISBONDINGOFEXTERIORPIPELINECOATINGSATELEVATEDTEMPERATURESUSINGINTERIORHEATING

链接地址:http://www.mydoc123.com/p-523218.html