ASTM D5076-1990(2006) Standard Test Method for Measuring Voids in Roofing and Waterproofing Membranes《屋顶层和防水膜中孔隙的测试方法》.pdf
《ASTM D5076-1990(2006) Standard Test Method for Measuring Voids in Roofing and Waterproofing Membranes《屋顶层和防水膜中孔隙的测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5076-1990(2006) Standard Test Method for Measuring Voids in Roofing and Waterproofing Membranes《屋顶层和防水膜中孔隙的测试方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5076 90 (Reapproved 2006)Standard Test Method forMeasuring Voids in Roofing and Waterproofing Membranes1This standard is issued under the fixed designation D 5076; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method includes two procedures for measuringthe area of voids in the adhesive between materials use
3、d inroofing and waterproofing systems. Both procedures require acount of the number of voids.1.2 The values given in SI units are to be regarded as thestandard. The values in parentheses are for information only.1.3 This standard does not purport to address all of thesafety concerns, if any, associa
4、ted with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1079 Terminology Relating to Roofing and Waterproof-ingD 2
5、829 Practice for Sampling and Analysis of Built-UpRoofs3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, see Terminology D 1079.4. Summary of Test Method4.1 All voids are counted and measured. In addition, inbuilt-up roofing and waterproofing membrane samples, voidsmay b
6、e classified into dry, glazed, uncoated, and overlyingvoids (see Terminology D 1079). Count and measure onlyvoids with at least one dimension equal to or larger than 13 mm(0.5 in.). Smaller adhesive layer defects are not consideredvoids.4.2 The void area in each adhesive layer is estimated withthe a
7、id of a template, or alternatively, digitized and measuredwith a computer.5. Significance and Use5.1 This laboratory test method can be used on multi-plyroofing and waterproofing systems to measure, classify, andcount the voids between felt plies, between insulation layers,and between the membrane a
8、nd insulation layers. Voids be-tween the felt plies or between the membrane and insulationlayer in multi-ply systems can be the seeds for future blisters.5.2 In one-ply systems, this test method can be used to countand measure the voids in the adhesive in laps and, in adheredsystems, in the adhesive
9、 between the membrane and theinsulation. Voids in the lapping adhesive can be the source ofleakage while voids in the lapping adhesive or in the adhesivebetween the membrane and insulation can be the seeds forfuture blisters.6. Apparatus6.1 Freezer, for conditioning bituminous samples. A stan-dard f
10、reezer, such as that used for storing frozen foods, may beused provided it has the volume to loosely hold the samples tobe tested. Do not store food and condition samples in the sameequipment.6.2 Transparent Sheets, to record the size and location of thevoids.Any clear, rigid sheet that can be marke
11、d with a flow pencan be used.6.3 Flow Pen, or other marking device that is compatiblewith the transparent sheet selected.6.4 Void Estimating TemplateA stiff, 305-mm2(12-in.2)transparent template with a 25.4-mm (1-in.) minimum grid.Special templates can be prepared and used with lap samples,or just p
12、art of the above template can be used.6.5 Computer Equipment and Software, for digitizing accu-rate images, image enhancement such as background leveling,noise cleaning and edge sharpening, and area determination bypixel (point of light) count.37. Sampling, Test Specimens, and Test Units7.1 Samples
13、may be from the laboratory or the field as inPractice D 2829.1This test method is under the jurisdiction ofASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.20 onRoofing Membrane Systems.Current edition approved Dec. 1, 2006. Published February 2007.
14、 Originallyapproved in 1990. Last previous edition approved in 2000 as D 5076 90 (2000)e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Sum
15、mary page onthe ASTM website.3The sole source of supply of the software known to the committee at this timeis Jandel Corp., 3030 Bridgeway, Sausalito, CA 94965. If you are aware ofalternative suppliers, please provide this information to ASTM InternationalHeadquarters. Your comments will receive car
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD507619902006STANDARDTESTMETHODFORMEASURINGVOIDSINROOFINGANDWATERPROOFINGMEMBRANES 屋顶 防水 孔隙 测试 方法

链接地址:http://www.mydoc123.com/p-518805.html