ASTM D5076 D5076M-2013 Standard Test Method for Measuring Voids in Roofing and Waterproofing Membranes《测量屋面料和防水膜中空隙的标准试验方法》.pdf
《ASTM D5076 D5076M-2013 Standard Test Method for Measuring Voids in Roofing and Waterproofing Membranes《测量屋面料和防水膜中空隙的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5076 D5076M-2013 Standard Test Method for Measuring Voids in Roofing and Waterproofing Membranes《测量屋面料和防水膜中空隙的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5076 90 (Reapproved 2006)D5076/D5076M 13Standard Test Method forMeasuring Voids in Roofing and Waterproofing Membranes1This standard is issued under the fixed designation D5076;D5076/D5076M; the number immediately following the designation indicatesthe year of original adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method includes two procedures for measuring the area of voids in the adhe
3、sive between materials used in roofingand waterproofing systems. Both procedures require a count of the number of voids.1.2 The values givenstated in either SI units or inch-pound units are to be regarded separately as the standard. The values inparentheses are for information only. stated in each s
4、ystem may not be exact equivalents; therefore, each system shall be usedindependently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is t
5、he responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1079 Terminology Relating to Roofing and WaterproofingD2829 Practice for Sampling and A
6、nalysis of Existing Built-Up Roof Systems3. Terminology3.1 DefinitionsFor definitions of terms used in this test method, see Terminology D1079.4. Summary of Test Method4.1 All voids are counted and measured. In addition, in built-up roofing and waterproofing membrane samples, voids may beclassified
7、into dry, glazed, uncoated, and overlying voids (see Terminology D1079). Count and measure only voids with at leastone dimension equal to or larger than 13 mm (0.5 in.).0.5 in. Smaller adhesive layer defects are not considered voids.4.2 The void area in each adhesive layer is estimated with the aid
8、of a template, or alternatively, digitized and measured witha computer.5. Significance and Use5.1 This laboratory test method can be used on multi-ply roofing and waterproofing systems to measure, classify, and count thevoids between felt plies, between insulation layers, and between the membrane an
9、d insulation layers. Voids between the felt pliesor between the membrane and insulation layer in multi-ply systems can be the seeds for future blisters.5.2 In one-ply systems, this test method can be used to count and measure the voids in the adhesive in laps and, in adheredsystems, in the adhesive
10、between the membrane and the insulation.Voids in the lapping adhesive can be the source of leakage whilevoids in the lapping adhesive or in the adhesive between the membrane and insulation can be the seeds for future blisters.6. Apparatus6.1 Freezer, for conditioning bituminous samples. A standard f
11、reezer, such as that used for storing frozen foods, may be usedprovided it has the volume to loosely hold the samples to be tested. Do not store food and condition samples in the same equipment.1 This test method is under the jurisdiction of ASTM Committee D08 on Roofing and Waterproofing and is the
12、 direct responsibility of Subcommittee D08.20 on RoofingMembrane Systems.Current edition approved Dec. 1, 2006Dec. 15, 2013. Published February 2007December 2013. Originally approved in 1990. Last previous edition approved in 20002006as D5076 90 (2000)(2006).1. DOI: 10.1520/D5076-90R06.10.1520/D5076
13、_D5076M-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is inten
14、ded only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the curren
15、t versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.2 Transparent Sheets, to record the size and location of the voids. Any clear, rigid sheet that
16、can be marked with a flow pencan be used.6.3 Flow Pen, or other marking device that is compatible with the transparent sheet selected.6.4 Void Estimating TemplateA stiff, 305-mm2 (12-in.12-in.2) transparent template with a 25.4-mm (1-in.)1-in. minimumgrid. Special templates can be prepared and used
17、with lap samples, or just part of the above template can be used.6.5 Computer Equipment and Image Analysis Software, for digitizing accurate images, image enhancement such as backgroundleveling, noise cleaning and edge sharpening, and area determination by pixel (point of light) count.digitalizing a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便