ASTM D5070-1990(2005) Standard Test Method for Synthetic Quaternary Ammonium Salts in Fabric Softeners by Potentiometric Titrations《采用电位滴定法的织物软化剂中合成季胺盐的标准试验方法》.pdf
《ASTM D5070-1990(2005) Standard Test Method for Synthetic Quaternary Ammonium Salts in Fabric Softeners by Potentiometric Titrations《采用电位滴定法的织物软化剂中合成季胺盐的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5070-1990(2005) Standard Test Method for Synthetic Quaternary Ammonium Salts in Fabric Softeners by Potentiometric Titrations《采用电位滴定法的织物软化剂中合成季胺盐的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5070 90 (Reapproved 2005)Standard Test Method forSynthetic Quaternary Ammonium Salts in Fabric Softenersby Potentiometric Titrations1This standard is issued under the fixed designation D 5070; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes a potentiometric titrationprocedure for the determina
3、tion of quaternary ammonium saltsin fabric softeners. This test method is intended for the analysisof known quaternary ammonium salts such as the dialkyldimethyl quaternary ammonium compound type and the dia-midoamine based quaternary ammonium compound type.1.2 The quaternary ammonium salts conform
4、to the struc-tures shown in Fig. 1 and Fig. 2.1.3 The analytical procedure appears in the following order:SectionApparatus 5Reagents 6Preparation of standard reagents 7Standardization of hyamine solution 9Safety precautions 8Procedure for determination of dialkyl dimethyl quaternaries 10Procedure fo
5、r determination of diamidoamine based quaternaries 111.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility o
6、f regulatory limitations prior to use. See 6.4, 6.6, 6.7and Section 8 for specific warning statements.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterD 3049 Test Method for Synthetic Anionic Ingredient byCationic Titration3. Summary of Test Method3.1 Quaternary ammon
7、ium compounds present in fabricsofteners, as the active materials, are titrated potentiometricallyin an aqueous medium with a standard solution of sodiumlauryl sulfate using a nitrate ion-selective electrode. In thispotentiometric titration, the reaction involves the formation ofa complex between th
8、e quaternary ammonium compound andthe anionic surfactant which then precipitates.At the end point,the nitrate ion electrode appears to respond to an excess oftitrant with a potential change large enough to give a welldefined inflection in the titration curve. Alternatively thequaternary ammonium com
9、pound can be first complexed withan excess of standard sodium lauryl sulfate; the excess sodiumlauryl sulfate is titrated potentiometrically with standardHyamine 1622.34. Significance and Use4.1 This test method is used to determine the quaternaryammonium salts commonly found in fabric softeners. Qu
10、ater-nary ammonium compounds being the active ingredients infabric softeners requires accurate determination to assess thecost and performance of such compounds.5. Apparatus5.1 Autotitration Systemburet with 10 or 20 mLcapacity;4magnetic stirrer;5evaluating ruler.65.2 Electrodes(1) nitrate specific
11、ion electrode;7(2) sur-factant electrode;8(3) Ag/AgCl reference electrode.91This test method is under the jurisdiction of ASTM Committee D12 on Soapsand Other Detergents and is the direct responsibility of Subcommittee D12.12 onAnalysis and Specifications of Soaps, Synthetics, Detergents and their C
12、omponents.Current edition approved May 1, 2005. Published June 2005. Originallyapproved in 1990. Last previous edition approved in 1997 as D 5070-90(1997).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM
13、Standards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole source of supply of Hyamine 1622 known to the committee at thistime is Gallard Schlesinger Manufacturing Corp., 584 Mineola Ave., Carle Place,NY 11514. If you are aware of alternative suppliers, p
14、lease provide this informationto ASTM Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee, which you may attend.4Metrohm-Brinkman E-536, or equivalent, has been found satisfactory. Avail-able from Brinkman Instruments Inc., Cantiague Rd.,
15、 Westbury, NY 11590.5Potentiograph/E-535 and Dosimat/E-459, or equivalent, have been foundsatisfactory. Available from Brinkman Instruments Inc., Cantiague Rd., Westbury,NY 11590.6Evaluating Ruler EA-893, or equivalent, has been found satisfactory. Availablefrom Brinkman Instruments Inc., Cantiague
16、Rd., Westbury, NY 11590.7Orion Model 93.07, or equivalent, has been found satisfactory. Available fromOrion Research Inc., 529 Main St., Boston, MA 02129.8Orion Model 93.42, or equivalent, has been found satisfactory. Available fromOrion Research Inc., 529 Main St., Boston, MA 02129.9Metrohm Model E
17、A-440, or equivalent, has been found satisfactory. Availablefrom Brinkman Instruments Inc., Cantiague Rd., Westbury, NY 11590.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 Adaptors(1) coaxial adaptor, required for indicatorelec
18、trode,10(2) banana plug adaptor, required for referenceelectrode.NOTE 1To ensure electrical continuity (after assembly) shake downelectrode in the manner of a clinical thermometer. Also, the conditioningof the electrode is essential for obtaining a good break in the titrationcurve. Conditioning new
19、electrodes in 0.01 M KNO3, aqueous solution for60 min (or more) prior to use is recommended.NOTE 2Other electrodes (for example, a calomel electrode) aresuitable as the reference electrode provided they give a stable referencepotential during the titration. Reference electrodes having a ceramic or a
20、nasbestos junction tend to clog with use. Therefore, a ground-glass sleeveelectrode (such as the Metrohm EA 440 or equivalent)11is suggested.6. Reagents6.1 Hyamine 1622,3diisobutylphenoxyethoxyethyl dim-ethyl benzyl ammonium chloride monohydrate.6.2 Sodium Lauryl Sulfate,12primary standard (Note 3).
21、NOTE 3Sodium lauryl sulfate must be analyzed for purity accordingto the Reagent section of Test Method D 3049, before its use as a primarystandard.6.3 Water, type III reagent water conforming to Specifica-tion D 1193.6.4 Isopropanol, reagent grade. (WarningHighly flam-mable.)6.5 Sodium Borate Decahy
22、drate(Na2B4O710H2O), re-agent grade.6.6 Boric Acid (H3BO3), reagent grade. (WarningCauses irritation.)6.7 Sulfuric Acid (H2SO4), reagent grade. (WarningCauses severe burns on contact with skin. See Section 8.)6.8 Five percent (V/V) Sulfuric Acid SolutionUsing agraduated cylinder, transfer 80 mL of d
23、eionized water to a100-mL volumetric flask. Slowly, carefully, and with stirring,add 5 mL of concentrated sulfuric acid. Cool to room tempera-ture and dilute to the mark with water.6.9 Borate Buffer Solution pH 6.00In a 500 mL beaker,dissolve 5.0 g 6 0.02 g of sodium borate decahydrate and 7.0g 6 0.
24、02 g of boric acid in approximately 300 mL water, withstirring; adjust pH to 6.00 with 5 % sulfuric acid solution.Transfer to a 500-mL volumetric flask, mix, and dilute tovolume with water.7. Preparation of Standard Reagents7.1 Sodium Lauryl Sulfate Solution, 4 3 103NWeighaccurately 1.15 6 0.01 g of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD507019902005STANDARDTESTMETHODFORSYNTHETICQUATERNARYAMMONIUMSALTSINFABRICSOFTENERSBYPOTENTIOMETRICTITRATIONS

链接地址:http://www.mydoc123.com/p-518790.html