1、Designation: D4782 10 (Reapproved 2016)Standard Test Method forPalladium in Molecular Sieve Catalyst by Wet Chemistry1This standard is issued under the fixed designation D4782; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of palladiumin molecular sieve-containing fresh catalysts with about 0
3、.5weight % of palladium.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this st
4、andard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD7442 Practice for Sample Preparation of Fluid CatalyticCracking Catalysts and Zeolites
5、 for ElementalAnalysis byInductively Coupled Plasma Atomic Emission Spectros-copyE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE456 Terminology Relating to Quality and StatisticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Metho
6、d3. Summary of Test Method3.1 The test sample is treated with hydrofluoric acid andevaporated to dryness to remove silica; the residue is fusedwith potassium pyrosulfate, and the cooled melt is dissolved in4%H2SO4. A measured excess of 0.01 N potassium iodide(KI) is added to precipitate palladium as
7、 palladium iodide(PdI2). The precipitate is filtered and washed, and a smallamount of sodium sulfite is added to the filtrate to reduce anyfree iodine to iodide. The excess iodide is titrated with 0.01 NAgNO3potentiometrically, using a silver electrode versus acalomel electrode. A second sample take
8、n at the same time isused to determine loss on ignition.4. Significance and Use4.1 This test method provides a means of determining thepalladium content in fresh catalysts containing molecularsieves.4.2 This test method is not intended to cover samplescontaining metals other than palladium.5. Appara
9、tus5.1 pH Meter with Millivolt Scale or automatic recordingtitrator.5.2 Silver-Sulfide Electrode.5.3 Silver-Silver Chloride Double Junction reference elec-trode with 10 % KNO3in the outer chamber.5.4 Fisher Burner.5.5 Low-Temperature Muffle Furnace, 450C.5.6 High-Temperature Muffle Furnace, 1000C.5.
10、7 Hot-Plate, with sand bath as a preferred option.5.8 Magnetic Stirrer and TFE-Fluorocarbon-Coated Stir-ring Bars.5.9 Burets, 25-mL, with 0.1-mL graduations or an equiva-lent.5.10 Volumetric Flasks, 1000-mL.5.11 High-Silica Beakers, 400-mL, with disposable boro-silicate beakers as an option. Alterna
11、tively, a petri dish can beused for the fusion step, with polypropylene beakers beingused thereafter.5.12 Watch Glasses, preferably ribbed, 87 mm.5.13 Analytical Balance, capable of weighing to nearest 0.1mg.5.14 Weighing Papers.5.15 Porcelain Crucibles, 10-mL.5.16 Graduated Cylinders, 5-mL, 10-mL,
12、25-mL, 100-mL.1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32.03 on ChemicalComposition.Current edition approved Jan. 1, 2016. Published January 2016. Originallyapproved in 1988. Last previous edition approved in 2004
13、 as D478204(2010).DOI: 10.1520/D4782-10R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM Int
14、ernational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.17 Filter Paper, Whatman No. 40, 11 cm.5.18 Funnel, filter.5.19 Desiccator.5.20 Crucible Cover, porcelain.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests
15、. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsuffici
16、ently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Specification D1193.6.3 Desiccant Molecular Sieve, type 4A.6.4 Filter Paper Pulp.NOTE 1Refer
17、 to Section 8 on Hazards in Practice D7442 for hazardsassociated with handling of acids.6.5 Hydrofluoric Acid (HF), 48 %.6.6 Potassium Iodide Solution, 0.01 NDissolve 1.66 g ofpotassium iodide (KI) in distilled water, dilute to 1000 mL, andmix well.6.7 Potassium Pyrosulfate (K2S2O8).6.8 Silver Nitra
18、te Solution, 0.01000 NDissolve 1.6989 gof silver nitrate (AgNO3) in distilled water, dilute to 1000 mL,and mix well.NOTE 2The preparation of the AgNO3standard solution is a criticalstep. If any traces of chloride, organic matter or reducing agents arepresent in the water, moreAgNO3will be used in th
19、e back-titration and thefinal result will be low. Standardization is recommended.6.9 Sodium Sulfite Solution, 10 % Dissolve 10 g of anhy-drous sodium sulfite (Na2SO3) in 100 mL of distilled water.6.10 Sulfuric Acid (H2SO4) concentrated, sp gr 1.84.6.11 Sulfuric Acid,48%or9MAdd slowly, stir one partc
20、oncentrated H2SO4(96 %) to one part water, then cool.6.12 Sulfuric Acid, 4 % or 0.72 MDilute 80 mL of 48 %sulfuric acid to 1000 mL.7. Procedure7.1 WeighingPrepare a carefully riffled, finely groundsample of ambient-equilibrated catalyst. For example, thesample could be thinly spread on filter paper
21、and exposed toroom conditions for 16 h.7.1.1 For determination of percent loss on ignition at1000C, ignite a porcelain crucible at 1000C for at least 30min, place in desiccator to cool, and weigh to nearest 0.1 mg.Transfer approximately 2.0 g of sample to the crucible andweigh to the nearest 0.1 mg.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD478220102016STANDARDTESTMETHODFORPALLADIUMINMOLECULARSIEVECATALYSTBYWETCHEMISTRY 采用 化学 测定 分子筛 催化剂

链接地址:http://www.mydoc123.com/p-517965.html