ASTM D4399-2005 Standard Test Method for Measuring Electrical Conductivity of Electrocoat Baths《电涂镀槽导电性测量的标准试验方法》.pdf
《ASTM D4399-2005 Standard Test Method for Measuring Electrical Conductivity of Electrocoat Baths《电涂镀槽导电性测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4399-2005 Standard Test Method for Measuring Electrical Conductivity of Electrocoat Baths《电涂镀槽导电性测量的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4399 05Standard Test Method forMeasuring Electrical Conductivity of Electrocoat Baths1This standard is issued under the fixed designation D 4399; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the elec-trical conductivity of electrocoat baths or ultrafiltrate samplesusing co
3、mmercially available equipment.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of
4、 this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1125 Test Methods for Electrical Conductivity and Re-sistivity of WaterD 1193 Specification for Reagent Water3. Su
5、mmary of Test Method3.1 A specimen is placed in a conductivity cell, or con-versely a conductivity cell is placed in an electrocoat material,and the cell is connected to a conductivity bridge. Theelectrical conductivity is read directly off the meter of thebridge as the instantaneous peak reading.4.
6、 Significance and Use4.1 The conductivity of electrocoat baths results from thepresence of ionic species in the bath, which come from thevehicle and from the presence of impurities present as ioniz-able acids, bases, salts, or combinations of these. The presenceof excessive amounts of ionic impuriti
7、es is detrimental to theapplication and performance properties of electrocoatingpaints. The test is suitable for use in research, production,quality control and electrocoat bath process control.4.2 Other related methods for determining the electricalconductivity of water are described in Test Method
8、s D 1125.5. Apparatus5.1 Conductivity BridgeBattery, or AC/DC line-operated,capable of providing a conductivity reading almost instanta-neously.5.2 Conductivity CellDip or fill type, cell constant of 1.0.5.3 ThermometerAny type capable of 0.5C accuracywith a 2 to 32C range.5.4 Measuring VesselAny su
9、itable cylindrical containercapable of holding sufficient electrocoat sample to cover theelectrodes of the conductivity cell, and allowing at least 25 mmbetween the conductivity cell and the sides of the vessel.6. Reagents and Materials6.1 Purity of WaterReferences to water shall be under-stood to m
10、ean water conforming to Type II of SpecificationD 1193.6.2 Cleaning SolventAn appropriate solvent for the elec-trocoat material under measurement.7. Sampling and Sample Preparation7.1 The sample should be obtained while the electrocoatbath is under proper circulation so that a uniform sample isobtai
11、ned. In the case of an ultrafiltrate, the material should bethoroughly mixed or stirred prior to sampling to ensureuniformity.7.2 After sampling and prior to removing a test specimen, itis mandatory that the samples be shaken or stirred until they arehomogeneous and free of any settled material. Thi
12、s is particu-larly important if there is a delay between sampling the bathand performing the test on the bath materials. The absence ofsettled material can be ascertained visually (in a transparentcontainer) or by inserting a spatula, scraping the bottom of thecontainer and making sure that there is
13、 no settled matter. Shakeor stir the sample until specimens are taken for measurement;THIS POINT IS VERY IMPORTANT.8. Procedure8.1 Calibrate the conductivity cell prior to use following themanufacturers instructions.8.2 Rinse the measuring container several times with por-tions of the electrocoat ma
14、terial under test.1This test method is under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, andApplications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved Jan. 1, 2005. Published Febr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD43992005STANDARDTESTMETHODFORMEASURINGELECTRICALCONDUCTIVITYOFELECTROCOATBATHS 电涂镀槽 导电性 测量 标准 试验

链接地址:http://www.mydoc123.com/p-516966.html