1、Designation: D 4584 05Standard Test Method forMeasuring Apparent pH of Electrocoat Baths1This standard is issued under the fixed designation D 4584; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the freehydrogen ion concentration of electrocoat baths and theirultrafiltrates.1.2 The values s
3、tated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
4、 and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterD 1293 Test Methods for pH of WaterE70 Test Method for pH of Aqueous Solutions with theGlass ElectrodeE 180 Practice for Dete
5、rmining the Precision Data ofASTM Methods for Analysis and Testing of IndustrialChemicals3. Summary of Test Method3.1 A specimen of a well-agitated electrocoat bath is placedin a stirrer-equipped container and the pH measured with a pHmeter and associated glass and reference electrodes.4. Significan
6、ce and Use4.1 The pH is the measure of the free hydrogen ionconcentration of a sample, and it indicates whether an electro-coat bath is acidic, neutral, or basic. Since pH measurements ofgood precision are made in aqueous solutions, it is suggestedthat the pH measurements of electrocoat baths are on
7、lysemi-quantitative, and therefore such measurements should bereferred to as apparent pH measurements.4.2 The pH of electrocoat paints is used for research,production, and quality control or electrocoat bath processcontrol.4.3 Other related methods for determining the pH of wateror aqueous systems a
8、re described in Test Methods D 1293 andE70.5. Apparatus5.1 pH Meter,5.2 Glass and Reference Electrodes.NOTE 1Due to the polarity of electrocoat materials it is desirable touse a separate set of electrodes for each bath polarity, cathodic and anodic,because a bath of opposite polarity poisons the ele
9、ctrodes. A desiredpractice is to rinse the electrodes after each measurement with anappropriate solvent for the electrocoat material.5.3 Thermometer, capable of 0.5C accuracy with a 2 to32C range.6. Reagents6.1 Reference Standard Solutions, commercial standards ofpH 4.0, 7.0, and 10.0.6.2 Purity of
10、WaterReferences to water shall be under-stood to mean water conforming to Type II of SpecificationD 1193.7. Sampling and Sample Preparation7.1 The sample should be obtained while the electrocoatbath is under proper circulation so that a uniform material isobtained. In case of an ultrafiltrate, the m
11、aterial should bethoroughly mixed or stirred prior to sampling to assureuniformity.7.2 After sampling and prior to removing a test specimen itis mandatory that the sample be shaken or stirred until it ishomogeneous and free of any settled material. This is particu-larly important if there is any del
12、ay between the sampling ofthe bath and the preparation of the specimens for the test. Theabsence of settled material can be ascertained visually (in atransparent container) or by inserting a spatula, scraping thebottom of the container to make sure that there is no settled1This test method is under
13、the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, andApplications and is the direct responsibility ofSubcommittee D01.21 on Chemical Analysis of Paints and Paint Materials.Current edition approved Jan. 1, 2005. Published February 2005. Originallyapproved in 1986. Last p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD45842005STANDARDTESTMETHODFORMEASURINGAPPARENTPHOFELECTROCOATBATHS 电涂镀槽 表观 PH 测量 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-517432.html